[grenoble] update data for yeti after the raid controller change

parent 3c925932
Pipeline #52812 passed with stages
in 1 minute and 39 seconds
......@@ -175,55 +175,55 @@
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c00223ab220cfc3b8e0",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0",
"by_id": "/dev/disk/by-id/wwn-0x55cd2e414de1d705",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0",
"device": "sda",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "SCV1DL53",
"interface": "SAS",
"model": "PERC H740P Adp",
"size": 479559942144,
"model": "SSDSC2KG480G7R",
"size": 480103981056,
"storage": "SSD",
"vendor": "DELL"
"vendor": "ATA"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc937c12e0d1b",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a08870d7",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0",
"device": "sdb",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93ac4f0fd93",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a0897757",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0",
"device": "sdc",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93dc8e0d879",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a0ae94bf",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0",
"device": "sdd",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.0025389671000bb3",
......
......@@ -175,55 +175,55 @@
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60023762be4210faa5e",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0",
"by_id": "/dev/disk/by-id/wwn-0x55cd2e414de16d7a",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0",
"device": "sda",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "SCV1DL53",
"interface": "SAS",
"model": "PERC H740P Adp",
"size": 479559942144,
"model": "SSDSC2KG480G7R",
"size": 480103981056,
"storage": "SSD",
"vendor": "DELL"
"vendor": "ATA"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60023762be421275098",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a08aab8f",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0",
"device": "sdb",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60023762be4213e8b27",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a088ce2f",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0",
"device": "sdc",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60023762be42155c247",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a0ae06af",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0",
"device": "sdd",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.0025389571001020",
......
......@@ -175,55 +175,55 @@
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d7caa2ee25",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0",
"by_id": "/dev/disk/by-id/wwn-0x55cd2e414de1d730",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0",
"device": "sda",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "SCV1DL53",
"interface": "SAS",
"model": "PERC H740P Adp",
"size": 479559942144,
"model": "SSDSC2KG480G7R",
"size": 480103981056,
"storage": "SSD",
"vendor": "DELL"
"vendor": "ATA"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d9ccfeedee",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a08a4beb",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0",
"device": "sdb",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92dbd095b1ac",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a089563f",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0",
"device": "sdc",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92ded465c604",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a0adf81f",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0",
"device": "sdd",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.002538957100101f",
......
......@@ -175,55 +175,55 @@
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb700223ab55ccfde5c8a",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0",
"by_id": "/dev/disk/by-id/wwn-0x55cd2e414de0fa6e",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0",
"device": "sda",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "SCV1DL53",
"interface": "SAS",
"model": "PERC H740P Adp",
"size": 479559942144,
"model": "SSDSC2KG480G7R",
"size": 480103981056,
"storage": "SSD",
"vendor": "DELL"
"vendor": "ATA"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaecc8ec4a10",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a08a9c6b",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0",
"device": "sdb",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf0ce536e29",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a08a7bb3",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0",
"device": "sdc",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf2d230b931",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0",
"by_id": "/dev/disk/by-id/wwn-0x5000c500a0ae58b3",
"by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0",
"device": "sdd",
"driver": "megaraid_sas",
"firmware_version": 5.03,
"firmware_version": "NT31",
"interface": "SAS",
"model": "PERC H740P Adp",
"model": "ST2000NX0463",
"reservation": true,
"size": 1999844147200,
"size": 2000398934016,
"storage": "HDD",
"vendor": "DELL"
"vendor": "SEAGATE"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.0025389671000bb5",
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment