[servan] Wattmetre ports numerotation starts at 0.

Merged JACQUOT Pierre requested to merge watt_servan into master

Related to bug 14117.

Servan's wattmetre port were misnumbered.

Wattmetre port numerotation starts at 0, not at 1.

This was causing the check-wattmetre-loss service to misread data, and think there was a mute port.