Commit 7403de6c authored by Clement Parisot's avatar Clement Parisot

[luxembourg] granduc - Fix #9178 for luxembourg

parent 08efbe37
......@@ -72,61 +72,77 @@
"device": "eth0",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"ip": "172.16.176.10",
"kavlan": true,
"mac": "00:22:19:6d:85:0a",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": true,
"name": "eno1",
"network_address": "granduc-10.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet2/10"
"switch_port": "GigabitEthernet2/10",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth1",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"kavlan": true,
"mac": "00:22:19:6d:85:0c",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": false,
"name": "eno2",
"network_address": "granduc-10-eth1.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet1/33"
"switch_port": "GigabitEthernet1/33",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth2",
"driver": "ixgbe",
"enabled": true,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:3d",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": true,
"mounted": false,
"name": "enp13s0f0",
"network_address": "granduc-10-eth2.luxembourg.grid5000.fr",
"rate": 10000000000,
"switch": "ul-grid5000-sw02",
"switch_port": "Ethernet1/11"
"switch_port": "Ethernet1/11",
"vendor": "Intel"
},
{
"bridged": false,
"device": "eth3",
"driver": "ixgbe",
"enabled": false,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:3c",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": false,
"mounted": false
"mounted": false,
"name": "enp13s0f1",
"vendor": "Intel"
},
{
"device": "bmc",
......
{
"architecture": {
"nb_cores": 8,
"nb_procs": 2,
"nb_threads": 8,
"platform_type": "x86_64"
},
"bios": {
"release_date": "10/30/2010",
"vendor": "Dell Inc.",
"version": "2.7.0"
},
"chassis": {
"manufacturer": "Dell Inc.",
"name": "PowerEdge 1950",
"serial": "30W883J"
},
"gpu": {
"gpu": false
},
"kavlan": {
"eth0": {
"kavlan-1": "192.168.193.11",
"kavlan-11": "10.7.212.11",
"kavlan-12": "10.11.212.11",
"kavlan-13": "10.15.212.11",
"kavlan-14": "10.19.212.11",
"kavlan-16": "10.27.212.11",
"kavlan-18": "10.35.212.11",
"kavlan-19": "10.39.212.11",
"kavlan-2": "192.168.209.11",
"kavlan-20": "10.43.212.11",
"kavlan-21": "10.47.212.11",
"kavlan-3": "192.168.225.11",
"kavlan-4": "10.40.1.11",
"kavlan-5": "10.40.65.11",
"kavlan-6": "10.40.129.11",
"kavlan-7": "10.40.193.11",
"kavlan-8": "10.41.1.11",
"kavlan-9": "10.41.65.11"
},
"eth1": {
"kavlan-1": "192.168.194.11",
"kavlan-11": "10.7.212.33",
"kavlan-12": "10.11.212.33",
"kavlan-13": "10.15.212.33",
"kavlan-14": "10.19.212.33",
"kavlan-16": "10.27.212.33",
"kavlan-18": "10.35.212.33",
"kavlan-19": "10.39.212.33",
"kavlan-2": "192.168.210.11",
"kavlan-20": "10.43.212.33",
"kavlan-21": "10.47.212.33",
"kavlan-3": "192.168.226.11",
"kavlan-4": "10.40.2.11",
"kavlan-5": "10.40.66.11",
"kavlan-6": "10.40.129.11",
"kavlan-7": "10.40.193.11",
"kavlan-8": "10.41.1.11",
"kavlan-9": "10.41.65.11"
}
},
"main_memory": {
"ram_size": 17179869184
},
"monitoring": {
"wattmeter": "false"
},
"network_adapters": [
{
"bridged": true,
"device": "eth0",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"ip": "172.16.176.11",
"kavlan": true,
"mac": "00:19:b9:f2:0f:46",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": true,
"name": "eno1",
"network_address": "granduc-11.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": null,
"switch_port": null,
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth1",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"kavlan": true,
"mac": "00:19:b9:f2:0f:48",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": false,
"name": "eno2",
"network_address": "granduc-11-eth1.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch_port": "Gi1/34",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth2",
"driver": "ixgbe",
"enabled": true,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:27",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": true,
"mounted": false,
"name": "enp13s0f0",
"network_address": "granduc-11-eth2.luxembourg.grid5000.fr",
"rate": 10000000000,
"switch_port": "Eth1/12",
"vendor": "Intel"
},
{
"bridged": false,
"device": "eth3",
"driver": "ixgbe",
"enabled": false,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:26",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": false,
"mounted": false,
"name": "enp13s0f1",
"vendor": "Intel"
},
{
"device": "bmc",
"enabled": true,
"interface": "Ethernet",
"ip": "172.17.176.11",
"kavlan": false,
"mac": "00:1c:23:d3:57:59",
"management": true,
"mountable": false,
"mounted": false,
"network_address": "granduc-11-bmc.luxembourg.grid5000.fr",
"switch": "gw-luxembourg",
"switch_port": "Gi1/11"
}
],
"operating_system": {
"cstate_driver": "none",
"cstate_governor": "menu",
"ht_enabled": false,
"pstate_driver": "none",
"pstate_governor": "none",
"turboboost_enabled": false
},
"performance": {
"core_flops": 6409000000.0,
"node_flops": 44070000000.0
},
"processor": {
"cache_l1": null,
"cache_l1d": 32768,
"cache_l1i": 32768,
"cache_l2": 4194304,
"cache_l3": 0,
"clock_speed": 2000000000,
"ht_capable": true,
"instruction_set": "x86-64",
"microarchitecture": "Clovertown",
"model": "Intel Xeon",
"other_description": "Intel(R) Xeon(R) CPU L5335 @ 2.00GHz",
"vendor": "Intel",
"version": "L5335"
},
"sensors": {
},
"storage_devices": [
{
"by_id": "node-was-not-available-to-retrieve-this-value",
"device": "sda",
"driver": "mptsas",
"interface": "SAS",
"model": "ST9146802SS",
"rev": "S22A",
"size": 146815733760,
"storage": "HDD",
"vendor": "SEAGATE"
}
],
"supported_job_types": {
"besteffort": true,
"deploy": true,
"max_walltime": 0,
"queues": [
"default",
"admin"
],
"virtual": "ivt"
},
"type": "node",
"uid": "granduc-11"
}
\ No newline at end of file
......@@ -81,7 +81,7 @@
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": true,
"name": "enp4s0",
"name": "eno1",
"network_address": "granduc-13.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
......@@ -101,7 +101,7 @@
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": false,
"name": "enp8s0",
"name": "eno2",
"network_address": "granduc-13-eth1.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
......@@ -162,7 +162,6 @@
"operating_system": {
"cstate_driver": "none",
"cstate_governor": "menu",
"cstate_max_id": null,
"ht_enabled": false,
"pstate_driver": "none",
"pstate_governor": "none",
......
......@@ -72,61 +72,77 @@
"device": "eth0",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"ip": "172.16.176.19",
"kavlan": true,
"mac": "00:19:b9:f2:0e:dd",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": true,
"name": "eno1",
"network_address": "granduc-19.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet2/19"
"switch_port": "GigabitEthernet2/19",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth1",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"kavlan": true,
"mac": "00:19:b9:f2:0e:df",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": false,
"name": "eno2",
"network_address": "granduc-19-eth1.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet2/31"
"switch_port": "GigabitEthernet2/31",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth2",
"driver": "ixgbe",
"enabled": true,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:3d:13:9b",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": true,
"mounted": false,
"name": "enp13s0f0",
"network_address": "granduc-19-eth2.luxembourg.grid5000.fr",
"rate": 10000000000,
"switch": "ul-grid5000-sw02",
"switch_port": "Ethernet1/20"
"switch_port": "Ethernet1/20",
"vendor": "Intel"
},
{
"bridged": false,
"device": "eth3",
"driver": "ixgbe",
"enabled": false,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:3d:13:9a",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": false,
"mounted": false
"mounted": false,
"name": "enp13s0f1",
"vendor": "Intel"
},
{
"device": "bmc",
......
......@@ -72,61 +72,77 @@
"device": "eth0",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"ip": "172.16.176.7",
"kavlan": true,
"mac": "00:19:b9:f2:0e:6f",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": true,
"name": "eno1",
"network_address": "granduc-7.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet2/7"
"switch_port": "GigabitEthernet2/7",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth1",
"driver": "bnx2",
"enabled": true,
"firmware_version": "6.4.5 bc 5.0.7 UMP 1.1.9",
"interface": "Ethernet",
"kavlan": true,
"mac": "00:19:b9:f2:0e:71",
"management": false,
"model": "NetXtreme II BCM5708 Gigabit Ethernet",
"mountable": true,
"mounted": false,
"name": "eno2",
"network_address": "granduc-7-eth1.luxembourg.grid5000.fr",
"rate": 1000000000,
"switch": "gw-luxembourg",
"switch_port": "GigabitEthernet1/30"
"switch_port": "GigabitEthernet1/30",
"vendor": "Broadcom"
},
{
"bridged": false,
"device": "eth2",
"driver": "ixgbe",
"enabled": true,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:5f",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": true,
"mounted": false,
"name": "enp13s0f0",
"network_address": "granduc-7-eth2.luxembourg.grid5000.fr",
"rate": 10000000000,
"switch": "ul-grid5000-sw02",
"switch_port": "Ethernet1/8"
"switch_port": "Ethernet1/8",
"vendor": "Intel"
},
{
"bridged": false,
"device": "eth3",
"driver": "ixgbe",
"enabled": false,
"firmware_version": "0xc7390000",
"interface": "Ethernet",
"kavlan": false,
"mac": "00:1b:21:34:e1:5e",
"management": false,
"model": "82598EB 10-Gigabit AF Dual Port Network Connection",
"mountable": false,
"mounted": false
"mounted": false,
"name": "enp13s0f1",
"vendor": "Intel"
},
{
"device": "bmc",
......
This diff is collapsed.
......@@ -68,5 +68,3 @@ nodes:
monitoring:
wattmeter: false
granduc-11:
status: retired
......@@ -23,28 +23,44 @@ granduc-10:
management: true
eth0:
driver: bnx2
firmware_version: 6.4.5 bc 5.0.7 UMP 1.1.9
interface: Ethernet
ip: 172.16.176.10
mac: 00:22:19:6d:85:0a
management: false
model: NetXtreme II BCM5708 Gigabit Ethernet
name: eno1
rate: 1000000000
vendor: Broadcom
eth1:
driver: bnx2
firmware_version: 6.4.5 bc 5.0.7 UMP 1.1.9
interface: Ethernet
mac: 00:22:19:6d:85:0c
management: false
model: NetXtreme II BCM5708 Gigabit Ethernet
name: eno2
rate: 1000000000
vendor: Broadcom
eth2:
driver: ixgbe
firmware_version: '0xc7390000'
interface: Ethernet
mac: 00:1b:21:34:e1:3d
management: false
model: 82598EB 10-Gigabit AF Dual Port Network Connection
name: enp13s0f0
rate: 10000000000
vendor: Intel
eth3:
driver: ixgbe
firmware_version: '0xc7390000'
interface: Ethernet
mac: 00:1b:21:34:e1:3c
management: false
model: 82598EB 10-Gigabit AF Dual Port Network Connection
name: enp13s0f1
vendor: Intel
operating_system:
cstate_driver: none
cstate_governor: menu
......
......@@ -20,44 +20,47 @@ granduc-11:
bmc:
ip: 172.17.176.11
mac: 00:1c:23:d3:57:59
management: true
eth0:
driver: bnx2
enabled: true
firmware_version: 6.4.5 bc 5.0.7 UMP 1.1.9
interface: Ethernet
ip: 172.16.176.11
ip6: fe80::219:b9ff:fef2:f46
mac: 00:19:b9:f2:0f:46
management: false
mountable: true
mounted: true
model: NetXtreme II BCM5708 Gigabit Ethernet
name: eno1
rate: 1000000000
vendor: Broadcom
eth1:
driver: bnx2
firmware_version: 6.4.5 bc 5.0.7 UMP 1.1.9
interface: Ethernet
ip: 172.16.178.11
mac: 00:19:b9:f2:0f:48
management: false
mountable: true
mounted: false
model: NetXtreme II BCM5708 Gigabit Ethernet
name: eno2
rate: 1000000000
vendor: Broadcom
eth2: