diff --git a/data/grid5000/sites/rennes/clusters/abacus2/abacus2.json b/data/grid5000/sites/rennes/clusters/abacus2/abacus2.json new file mode 100644 index 0000000000000000000000000000000000000000..cc3054577bde97b2dcbbd12a82d04efce0deb3c8 --- /dev/null +++ b/data/grid5000/sites/rennes/clusters/abacus2/abacus2.json @@ -0,0 +1,16 @@ +{ + "boot_type": "bios", + "created_at": "Fri, 10 Nov 2023 00:00:00 GMT", + "exotic": false, + "kavlan": false, + "metrics": [ + + ], + "model": "Dell PowerEdge R730", + "queues": [ + "admin", + "testing" + ], + "type": "cluster", + "uid": "abacus2" +} \ No newline at end of file diff --git a/data/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.json b/data/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.json new file mode 100644 index 0000000000000000000000000000000000000000..18e1a0383d3b4cdfbf990dce64edab487d689510 --- /dev/null +++ b/data/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.json @@ -0,0 +1,254 @@ +{ + "architecture": { + "cpu_core_numbering": "round-robin", + "nb_cores": 16, + "nb_procs": 2, + "nb_threads": 16, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "03/15/2023", + "vendor": "Dell Inc.", + "version": "2.17.0" + }, + "bmc_version": "2.85.85.85", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R730", + "serial": "7PGR1L2" + }, + "exotic": false, + "gpu_devices": { + "nvidia0": { + "compute_capability": "6.0", + "cores": 3584, + "cpu_affinity": 0, + "device": "/dev/nvidia0", + "memory": 17070817280, + "microarchitecture": "Pascal", + "model": "Tesla P100-PCIE-16GB", + "performance": { + "fp-16": 19050000000000, + "fp-32": 9526000000000, + "fp-64": 4763000000000 + }, + "power_default_limit": "250.00 W", + "vbios_version": "86.00.3A.00.03", + "vendor": "Nvidia" + }, + "nvidia1": { + "compute_capability": "6.0", + "cores": 3584, + "cpu_affinity": 1, + "device": "/dev/nvidia1", + "memory": 17070817280, + "microarchitecture": "Pascal", + "model": "Tesla P100-PCIE-16GB", + "performance": { + "fp-16": 19050000000000, + "fp-32": 9526000000000, + "fp-64": 4763000000000 + }, + "power_default_limit": "250.00 W", + "vbios_version": "86.00.3A.00.03", + "vendor": "Nvidia" + } + }, + "main_memory": { + "ram_size": 68719476736 + }, + "management_tools": { + "bmc_vendor_tool": "racadm", + "ipmitool": { + "retries": 5 + } + }, + "memory_devices": [ + { + "device": "dimm_a1", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_a2", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_a3", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_a4", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_b1", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_b2", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_b3", + "size": 8589934592, + "technology": "dram" + }, + { + "device": "dimm_b4", + "size": 8589934592, + "technology": "dram" + } + ], + "network_adapters": [ + { + "device": "eth0", + "driver": "igb", + "enabled": true, + "firmware_version": "1.67, 0x80000faa, 19.5.12", + "interface": "Ethernet", + "ip": "172.16.109.2", + "ip6": "2001:660:4406:700:e::2", + "kavlan": false, + "mac": "24:6e:96:69:48:54", + "management": false, + "model": "I350 Gigabit Network Connection", + "mountable": true, + "mounted": true, + "name": "eno1", + "network_address": "abacus2-1.rennes.grid5000.fr", + "rate": 1000000000, + "sriov": true, + "sriov_totalvfs": 7, + "switch": null, + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "igb", + "enabled": false, + "firmware_version": "1.67, 0x80000faa, 19.5.12", + "interface": "Ethernet", + "kavlan": false, + "mac": "24:6e:96:69:48:55", + "management": false, + "model": "I350 Gigabit Network Connection", + "mountable": false, + "mounted": false, + "name": "eno2", + "sriov": true, + "sriov_totalvfs": 7, + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "igb", + "enabled": false, + "firmware_version": "1.67, 0x80000faa, 19.5.12", + "interface": "Ethernet", + "kavlan": false, + "mac": "24:6e:96:69:48:56", + "management": false, + "model": "I350 Gigabit Network Connection", + "mountable": false, + "mounted": false, + "name": "eno3", + "sriov": true, + "sriov_totalvfs": 7, + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "igb", + "enabled": false, + "firmware_version": "1.67, 0x80000faa, 19.5.12", + "interface": "Ethernet", + "kavlan": false, + "mac": "24:6e:96:69:48:57", + "management": false, + "model": "I350 Gigabit Network Connection", + "mountable": false, + "mounted": false, + "name": "eno4", + "sriov": true, + "sriov_totalvfs": 7, + "vendor": "Intel" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.109.2", + "kavlan": false, + "mac": "50:9a:4c:64:9b:89", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "abacus2-1-bmc.rennes.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "ht_enabled": false, + "pstate_driver": "intel_cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": false + }, + "performance": { + "core_flops": 13600000000, + "node_flops": 217600000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 262144, + "cache_l3": 20971520, + "clock_speed": 1700000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Sandy Bridge", + "microcode": "0xb000040", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) CPU E5-2609 v4 @ 1.70GHz", + "vendor": "Intel", + "version": "E5-2609 v4" + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2023092009", + "standard-environment": "debian11-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x6107d1a0ff26b8002126d6f512642ace", + "by_path": "/dev/disk/by-path/pci-0000:02:00.0-scsi-0:2:0:0", + "firmware_version": 4.3, + "id": "disk0", + "interface": "SAS", + "model": "PERC H330 Mini", + "size": 299439751168, + "storage": "HDD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 0, + "queues": [ + "admin", + "testing" + ], + "virtual": "ivt" + }, + "type": "node", + "uid": "abacus2-1" +} \ No newline at end of file diff --git a/input/grid5000/sites/rennes/clusters/abacus2/abacus2.yaml b/input/grid5000/sites/rennes/clusters/abacus2/abacus2.yaml new file mode 100644 index 0000000000000000000000000000000000000000..306a7f796568899199df35cc4d346ded6f858b83 --- /dev/null +++ b/input/grid5000/sites/rennes/clusters/abacus2/abacus2.yaml @@ -0,0 +1,47 @@ +model: Dell PowerEdge R730 +created_at: 2023-11-10 +kavlan: false +boot_type: bios +exotic: false +queues: + - admin + - testing +nodes: + abacus2-1: + supported_job_types: + deploy: true + besteffort: true + max_walltime: 0 + processor: + microarchitecture: Sandy Bridge + clock_speed: 1700000000 + software: + standard-environment: debian11-x64-std + management_tools: + bmc_vendor_tool: racadm + network_adapters: + bmc: + interface: Ethernet + enabled: true + mountable: false + mounted: false + eth0: + enabled: true + mountable: true + mounted: true + eth1: + enabled: false + mountable: false + mounted: false + eth2: + enabled: false + mountable: false + mounted: false + eth3: + enabled: false + mountable: false + mounted: false + storage_devices: + pci-0000:02:00.0-scsi-0:2:0:0: + id: disk0 + interface: SAS diff --git a/input/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.yaml b/input/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.yaml new file mode 100644 index 0000000000000000000000000000000000000000..d3f934a3629c9d863be9ee7aa86fbf8eec171bb7 --- /dev/null +++ b/input/grid5000/sites/rennes/clusters/abacus2/nodes/abacus2-1.yaml @@ -0,0 +1,142 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +abacus2-1: + architecture: + cpu_core_numbering: round-robin + nb_cores: 16 + nb_procs: 2 + nb_threads: 16 + platform_type: x86_64 + bios: + release_date: 03/15/2023 + vendor: Dell Inc. + version: 2.17.0 + bmc_version: 2.85.85.85 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R730 + serial: 7PGR1L2 + gpu_devices: + nvidia0: + cpu_affinity: 0 + device: "/dev/nvidia0" + memory: 17070817280 + model: Tesla P100-PCIE-16GB + power_default_limit: 250.00 W + vbios_version: 86.00.3A.00.03 + vendor: Nvidia + nvidia1: + cpu_affinity: 1 + device: "/dev/nvidia1" + memory: 17070817280 + model: Tesla P100-PCIE-16GB + power_default_limit: 250.00 W + vbios_version: 86.00.3A.00.03 + vendor: Nvidia + main_memory: + ram_size: 68719476736 + memory_devices: + dimm_a1: + size: 8589934592 + technology: dram + dimm_a2: + size: 8589934592 + technology: dram + dimm_a3: + size: 8589934592 + technology: dram + dimm_a4: + size: 8589934592 + technology: dram + dimm_b1: + size: 8589934592 + technology: dram + dimm_b2: + size: 8589934592 + technology: dram + dimm_b3: + size: 8589934592 + technology: dram + dimm_b4: + size: 8589934592 + technology: dram + network_adapters: + bmc: + ip: 172.17.109.2 + mac: 50:9a:4c:64:9b:89 + management: true + eth0: + driver: igb + firmware_version: 1.67, 0x80000faa, 19.5.12 + interface: Ethernet + ip: 172.16.109.2 + mac: 24:6e:96:69:48:54 + management: false + model: I350 Gigabit Network Connection + name: eno1 + rate: 1000000000 + sriov: true + sriov_totalvfs: 7 + vendor: Intel + eth1: + driver: igb + firmware_version: 1.67, 0x80000faa, 19.5.12 + interface: Ethernet + mac: 24:6e:96:69:48:55 + management: false + model: I350 Gigabit Network Connection + name: eno2 + sriov: true + sriov_totalvfs: 7 + vendor: Intel + eth2: + driver: igb + firmware_version: 1.67, 0x80000faa, 19.5.12 + interface: Ethernet + mac: 24:6e:96:69:48:56 + management: false + model: I350 Gigabit Network Connection + name: eno3 + sriov: true + sriov_totalvfs: 7 + vendor: Intel + eth3: + driver: igb + firmware_version: 1.67, 0x80000faa, 19.5.12 + interface: Ethernet + mac: 24:6e:96:69:48:57 + management: false + model: I350 Gigabit Network Connection + name: eno4 + sriov: true + sriov_totalvfs: 7 + vendor: Intel + operating_system: + cstate_driver: intel_idle + cstate_governor: menu + ht_enabled: false + pstate_driver: intel_cpufreq + pstate_governor: performance + turboboost_enabled: false + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 262144 + cache_l3: 20971520 + ht_capable: true + instruction_set: x86-64 + microcode: '0xb000040' + model: Intel Xeon + other_description: Intel(R) Xeon(R) CPU E5-2609 v4 @ 1.70GHz + vendor: Intel + version: E5-2609 v4 + storage_devices: + pci-0000:02:00.0-scsi-0:2:0:0: + by_id: "/dev/disk/by-id/wwn-0x6107d1a0ff26b8002126d6f512642ace" + by_path: "/dev/disk/by-path/pci-0000:02:00.0-scsi-0:2:0:0" + firmware_version: 4.3 + model: PERC H330 Mini + size: 299439751168 + storage: HDD + supported_job_types: + virtual: ivt diff --git a/lib/refrepo/net_names_mapping.yaml b/lib/refrepo/net_names_mapping.yaml index 90f5ed36c6eee26a461a4af9daff1c50f86a4417..69b2c6f12f265363ae5a21e9d54c4f61655c40ab 100644 --- a/lib/refrepo/net_names_mapping.yaml +++ b/lib/refrepo/net_names_mapping.yaml @@ -4,6 +4,11 @@ abacus1: eno2: eth3 eno3: eth0 eno4: eth1 +abacus2: + eno1: eth0 + eno2: eth1 + eno3: eth2 + eno4: eth3 abacus3: eno1: eth0 eno2: eth1