Skip to content
GitLab
Menu
Projects
Groups
Snippets
Loading...
Help
Help
Support
Community forum
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in
Toggle navigation
Menu
Open sidebar
grid5000
reference-repository
Commits
c8371832
Commit
c8371832
authored
Apr 19, 2016
by
PARISOT Clement
Browse files
[nancy] graphique - Update default interface (eth0)
parent
4338e369
Changes
7
Hide whitespace changes
Inline
Side-by-side
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-1.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.1"
,
"mac"
:
"b0:83:fe:e5:c0:54"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-1.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"b0:83:fe:e5:c0:58"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-1-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/47"
,
"vendor"
:
"Broadcom"
},
{
...
...
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-2.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.2"
,
"mac"
:
"44:a8:42:07:6a:c8"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-2.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"44:a8:42:07:6a:cc"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-2-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/22"
,
"vendor"
:
"Broadcom"
},
{
...
...
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-3.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.3"
,
"mac"
:
"44:a8:42:0a:33:3d"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-3.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"44:a8:42:0a:33:41"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-3-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/44"
,
"vendor"
:
"Broadcom"
},
{
...
...
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-4.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.4"
,
"mac"
:
"44:a8:42:0a:8d:0d"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-4.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"44:a8:42:0a:8d:11"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-4-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/45"
,
"vendor"
:
"Broadcom"
},
{
...
...
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-5.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.5"
,
"mac"
:
"44:a8:42:0a:4b:9b"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-5.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"44:a8:42:0a:4b:9f"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-5-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/46"
,
"vendor"
:
"Broadcom"
},
{
...
...
data/grid5000/sites/nancy/clusters/graphique/nodes/graphique-6.json
View file @
c8371832
...
...
@@ -29,17 +29,18 @@
},
"network_adapters"
:
[
{
"bridged"
:
fals
e
,
"bridged"
:
tru
e
,
"device"
:
"eth0"
,
"driver"
:
"bnx2x"
,
"enabled"
:
fals
e
,
"enabled"
:
tru
e
,
"interface"
:
"Ethernet"
,
"ip"
:
"172.16.67.6"
,
"mac"
:
"44:a8:42:15:cd:e6"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 10 GB DA/SFP+"
,
"mountable"
:
fals
e
,
"mountable"
:
tru
e
,
"mounted"
:
true
,
"network_address"
:
"graphique-6.nancy.grid5000.fr"
,
"rate"
:
10000000000
,
"switch"
:
null
,
"switch_port"
:
null
,
...
...
@@ -60,19 +61,16 @@
"vendor"
:
"Broadcom"
},
{
"bridged"
:
tru
e
,
"bridged"
:
fals
e
,
"device"
:
"eth2"
,
"driver"
:
"bnx2x"
,
"enabled"
:
tru
e
,
"enabled"
:
fals
e
,
"interface"
:
"Ethernet"
,
"mac"
:
"44:a8:42:15:cd:ea"
,
"management"
:
false
,
"model"
:
"Broadcom 57800 1 GB Base-T"
,
"mountable"
:
tru
e
,
"mountable"
:
fals
e
,
"mounted"
:
false
,
"network_address"
:
"graphique-6-eth2.nancy.grid5000.fr"
,
"switch"
:
"stalc1"
,
"switch_port"
:
"GigabitEthernet1/0/23"
,
"vendor"
:
"Broadcom"
},
{
...
...
dev/input/grid5000/sites/nancy/clusters/graphique/graphique.yaml
View file @
c8371832
...
...
@@ -44,10 +44,9 @@ nodes:
vendor
:
null
network_adapters
:
eth0
:
enabled
:
false
mountable
:
false
rate
:
10000000000
bridged
:
false
enabled
:
true
mountable
:
true
bridged
:
true
vendor
:
Broadcom
model
:
Broadcom 57800 10 GB DA/SFP+
switch
:
null
...
...
@@ -61,9 +60,9 @@ nodes:
vendor
:
Broadcom
model
:
Broadcom 57800 10 GB DA/SFP+
eth2
:
mountable
:
tru
e
enabled
:
tru
e
bridged
:
tru
e
mountable
:
fals
e
enabled
:
fals
e
bridged
:
fals
e
vendor
:
Broadcom
model
:
Broadcom 57800 1 GB Base-T
eth3
:
...
...
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
.
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment