diff --git a/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.json b/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.json new file mode 100644 index 0000000000000000000000000000000000000000..76331c4b5824f99c6bda4c8c2fa4df67ec18c109 --- /dev/null +++ b/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.json @@ -0,0 +1,227 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous-including-threads", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 48, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "10/06/2021", + "vendor": "Dell Inc.", + "version": "2.5.6" + }, + "bmc_version": "5.10", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "CK3R3L3" + }, + "exotic": true, + "main_memory": { + "ram_size": 137438953472 + }, + "management_tools": { + "bmc_vendor_tool": "ipmitool", + "ipmitool": { + "retries": 5 + } + }, + "memory_devices": [ + { + "device": "dimm_a1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a4", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b4", + "size": 17179869184, + "technology": "dram" + } + ], + "network_adapters": [ + { + "device": "eth0", + "driver": "ice", + "enabled": true, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "ip": "172.16.23.1", + "ip6": "2001:660:4406:100:8::1", + "kavlan": false, + "mac": "40:a6:b7:6b:1d:b0", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "servan-1.grenoble.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "gw", + "switch_port": "ethernet1/1/81:1", + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:1d:b1", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:1d:b2", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno35", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:1d:b3", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno36", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.23.1", + "kavlan": false, + "mac": "b0:7b:25:f6:49:8e", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "servan-1-bmc.grenoble.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": false, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 36800000000, + "node_flops": 1766400000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2300000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen 2", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2022012700", + "standard-environment": "debian11-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/nvme-eui.36435430527023640025384100000003", + "by_path": "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1", + "id": "disk0", + "interface": "NVME", + "model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB", + "size": 1600321314816, + "storage": "SSD", + "vendor": "Dell" + }, + { + "by_id": "/dev/disk/by-id/nvme-eui.36435430527022630025384100000003", + "by_path": "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1", + "id": "disk1", + "interface": "NVME", + "model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB", + "size": 1600321314816, + "storage": "SSD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 0, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "servan-1" +} \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.json b/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.json new file mode 100644 index 0000000000000000000000000000000000000000..8b405edf7192a9111385ef2d857eadddeec0e863 --- /dev/null +++ b/data/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.json @@ -0,0 +1,227 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous-including-threads", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 48, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "10/06/2021", + "vendor": "Dell Inc.", + "version": "2.5.6" + }, + "bmc_version": "5.10", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "BK3R3L3" + }, + "exotic": true, + "main_memory": { + "ram_size": 137438953472 + }, + "management_tools": { + "bmc_vendor_tool": "ipmitool", + "ipmitool": { + "retries": 5 + } + }, + "memory_devices": [ + { + "device": "dimm_a1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a4", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b4", + "size": 17179869184, + "technology": "dram" + } + ], + "network_adapters": [ + { + "device": "eth0", + "driver": "ice", + "enabled": true, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "ip": "172.16.23.2", + "ip6": "2001:660:4406:100:8::2", + "kavlan": false, + "mac": "40:a6:b7:6b:13:40", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "servan-2.grenoble.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "gw", + "switch_port": "ethernet1/1/82:1", + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:13:41", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:13:42", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno35", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "ice", + "enabled": false, + "firmware_version": "3.00 0x8000893f 20.5.13", + "interface": "Ethernet", + "kavlan": false, + "mac": "40:a6:b7:6b:13:43", + "management": false, + "model": "Ethernet Controller E810-C for SFP", + "mountable": false, + "mounted": false, + "name": "eno36", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.23.2", + "kavlan": false, + "mac": "b0:7b:25:f6:40:a6", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "servan-2-bmc.grenoble.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": false, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 36800000000, + "node_flops": 1766400000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2300000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen 2", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2022012700", + "standard-environment": "debian11-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/nvme-eui.36435430527022550025384100000003", + "by_path": "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1", + "id": "disk0", + "interface": "NVME", + "model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB", + "size": 1600321314816, + "storage": "SSD", + "vendor": "Dell" + }, + { + "by_id": "/dev/disk/by-id/nvme-eui.36435430527022640025384100000003", + "by_path": "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1", + "id": "disk1", + "interface": "NVME", + "model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB", + "size": 1600321314816, + "storage": "SSD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 0, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "servan-2" +} \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/servan/servan.json b/data/grid5000/sites/grenoble/clusters/servan/servan.json new file mode 100644 index 0000000000000000000000000000000000000000..ea68137c9bc72dba8b5b6e715c212c199cb75f00 --- /dev/null +++ b/data/grid5000/sites/grenoble/clusters/servan/servan.json @@ -0,0 +1,103 @@ +{ + "boot_type": "uefi", + "created_at": "Wed, 15 Dec 2021 00:00:00 GMT", + "exotic": true, + "kavlan": false, + "metrics": [ + { + "description": "Input byte counter for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifacein_bytes_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output byte counter for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifaceout_bytes_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input packet counter for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifacein_packets_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output packet counter for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifaceout_packets_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of discarded packets for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifacein_packets_discard_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of discarded packets for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifaceout_packets_discard_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of packet errors for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifacein_packets_error_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of packet errors for the network device port", + "labels": { + "interface": "eth0" + }, + "name": "network_ifaceout_packets_error_total", + "period": 15000, + "source": { + "protocol": "network_equipment" + } + } + ], + "model": "Dell PowerEdge R7525", + "queues": [ + "admin", + "testing" + ], + "type": "cluster", + "uid": "servan" +} \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/network_equipments/gw.json b/data/grid5000/sites/grenoble/network_equipments/gw.json index e7c5c45ac24025f5517ae33693c3c046f4acbbdd..9828d99e5ef561b82b9878558b61cbeb838651f1 100644 --- a/data/grid5000/sites/grenoble/network_equipments/gw.json +++ b/data/grid5000/sites/grenoble/network_equipments/gw.json @@ -411,8 +411,16 @@ "uid": "troll-4" }, { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/81:1", + "uid": "servan-1" }, { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/82:1", + "uid": "servan-2" }, { "kind": "channel", diff --git a/input/grid5000/disks.yaml b/input/grid5000/disks.yaml index 27ff6692bcc3d2552416563164dc242a96f4cbb9..f30afeae7ba187017b9f330c206a536c582077d7 100644 --- a/input/grid5000/disks.yaml +++ b/input/grid5000/disks.yaml @@ -96,6 +96,7 @@ disk_vendor_model_mapping: - Dell Express Flash NVMe PM1725 1.6TB AIC - Dell Express Flash PM1725b 1.6TB AIC - Dell Ent NVMe AGN MU AIC 1.6TB + - Dell Ent NVMe v2 AGN MU U.2 1.6TB Samsung: - SAMSUNG MZ1LB1T9HALS-00007 Kioxia: diff --git a/input/grid5000/ipv4.yaml b/input/grid5000/ipv4.yaml index 2d358a819198a4b55a4d9325d0e9bf9bed7e07bd..c7dddf82064851255c8d1bc9bad8a6d809cdb45c 100644 --- a/input/grid5000/ipv4.yaml +++ b/input/grid5000/ipv4.yaml @@ -14,6 +14,7 @@ ipv4: grenoble yeti eth0 0 0 3 0 grenoble dahu eth0 0 0 4 0 grenoble troll eth0 0 0 6 0 + grenoble servan eth0 0 0 7 0 grenoble drac eth0 0 0 8 0 lille chifflot eth0 0 0 4 0 lille chifflot eth1 0 0 4 100 diff --git a/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.yaml b/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.yaml new file mode 100644 index 0000000000000000000000000000000000000000..57fd0d94da5b1bc6679a139b2ddd707d2de94803 --- /dev/null +++ b/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-1.yaml @@ -0,0 +1,130 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +servan-1: + architecture: + cpu_core_numbering: contiguous-including-threads + nb_cores: 48 + nb_procs: 2 + nb_threads: 48 + platform_type: x86_64 + bios: + release_date: 10/06/2021 + vendor: Dell Inc. + version: 2.5.6 + bmc_version: '5.10' + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: CK3R3L3 + main_memory: + ram_size: 137438953472 + memory_devices: + dimm_a1: + size: 17179869184 + technology: dram + dimm_a2: + size: 17179869184 + technology: dram + dimm_a3: + size: 17179869184 + technology: dram + dimm_a4: + size: 17179869184 + technology: dram + dimm_b1: + size: 17179869184 + technology: dram + dimm_b2: + size: 17179869184 + technology: dram + dimm_b3: + size: 17179869184 + technology: dram + dimm_b4: + size: 17179869184 + technology: dram + network_adapters: + bmc: + ip: 172.17.23.1 + mac: b0:7b:25:f6:49:8e + management: true + eth0: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + ip: 172.16.23.1 + mac: 40:a6:b7:6b:1d:b0 + management: false + model: Ethernet Controller E810-C for SFP + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth1: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:1d:b1 + management: false + model: Ethernet Controller E810-C for SFP + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth2: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:1d:b2 + management: false + model: Ethernet Controller E810-C for SFP + name: eno35 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth3: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:1d:b3 + management: false + model: Ethernet Controller E810-C for SFP + name: eno36 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: false + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + pci-0000:c3:00.0-nvme-1: + by_id: "/dev/disk/by-id/nvme-eui.36435430527023640025384100000003" + by_path: "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1" + model: Dell Ent NVMe v2 AGN MU U.2 1.6TB + size: 1600321314816 + storage: SSD + pci-0000:c4:00.0-nvme-1: + by_id: "/dev/disk/by-id/nvme-eui.36435430527022630025384100000003" + by_path: "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1" + model: Dell Ent NVMe v2 AGN MU U.2 1.6TB + size: 1600321314816 + storage: SSD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.yaml b/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.yaml new file mode 100644 index 0000000000000000000000000000000000000000..5018eee93a1a4d32bed763e71c2e91650f7f8498 --- /dev/null +++ b/input/grid5000/sites/grenoble/clusters/servan/nodes/servan-2.yaml @@ -0,0 +1,130 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +servan-2: + architecture: + cpu_core_numbering: contiguous-including-threads + nb_cores: 48 + nb_procs: 2 + nb_threads: 48 + platform_type: x86_64 + bios: + release_date: 10/06/2021 + vendor: Dell Inc. + version: 2.5.6 + bmc_version: '5.10' + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: BK3R3L3 + main_memory: + ram_size: 137438953472 + memory_devices: + dimm_a1: + size: 17179869184 + technology: dram + dimm_a2: + size: 17179869184 + technology: dram + dimm_a3: + size: 17179869184 + technology: dram + dimm_a4: + size: 17179869184 + technology: dram + dimm_b1: + size: 17179869184 + technology: dram + dimm_b2: + size: 17179869184 + technology: dram + dimm_b3: + size: 17179869184 + technology: dram + dimm_b4: + size: 17179869184 + technology: dram + network_adapters: + bmc: + ip: 172.17.23.2 + mac: b0:7b:25:f6:40:a6 + management: true + eth0: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + ip: 172.16.23.2 + mac: 40:a6:b7:6b:13:40 + management: false + model: Ethernet Controller E810-C for SFP + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth1: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:13:41 + management: false + model: Ethernet Controller E810-C for SFP + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth2: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:13:42 + management: false + model: Ethernet Controller E810-C for SFP + name: eno35 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth3: + driver: ice + firmware_version: 3.00 0x8000893f 20.5.13 + interface: Ethernet + mac: 40:a6:b7:6b:13:43 + management: false + model: Ethernet Controller E810-C for SFP + name: eno36 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: false + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + pci-0000:c3:00.0-nvme-1: + by_id: "/dev/disk/by-id/nvme-eui.36435430527022550025384100000003" + by_path: "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1" + model: Dell Ent NVMe v2 AGN MU U.2 1.6TB + size: 1600321314816 + storage: SSD + pci-0000:c4:00.0-nvme-1: + by_id: "/dev/disk/by-id/nvme-eui.36435430527022640025384100000003" + by_path: "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1" + model: Dell Ent NVMe v2 AGN MU U.2 1.6TB + size: 1600321314816 + storage: SSD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/grenoble/clusters/servan/servan.yaml b/input/grid5000/sites/grenoble/clusters/servan/servan.yaml new file mode 100644 index 0000000000000000000000000000000000000000..af10adec7b424a4f6d3e1c49ce302b07ec70175a --- /dev/null +++ b/input/grid5000/sites/grenoble/clusters/servan/servan.yaml @@ -0,0 +1,49 @@ +model: Dell PowerEdge R7525 +created_at: 2021-12-15 +kavlan: false +boot_type: uefi +exotic: true +queues: + - admin + - testing +nodes: + servan-[1-2]: + supported_job_types: + deploy: true + besteffort: true + max_walltime: 0 + processor: + microarchitecture: Zen 2 + clock_speed: 2300000000 + software: + standard-environment: debian11-x64-std + network_adapters: + bmc: + interface: Ethernet + enabled: true + mountable: false + mounted: false + eth0: + enabled: true + mountable: true + mounted: true + eth1: + enabled: false + mountable: false + mounted: false + eth2: + enabled: false + mountable: false + mounted: false + eth3: + enabled: false + mountable: false + mounted: false + storage_devices: + pci-0000:c3:00.0-nvme-1: + interface: NVME + id: disk0 + pci-0000:c4:00.0-nvme-1: + interface: NVME + id: disk1 + diff --git a/input/grid5000/sites/grenoble/networks/gw-grenoble.yaml b/input/grid5000/sites/grenoble/networks/gw-grenoble.yaml index eb2b6736dc2e8a005b2bda61c7164752199596f5..d7a7e8ade264b859d7c720d1f858b824f7c2cd36 100644 --- a/input/grid5000/sites/grenoble/networks/gw-grenoble.yaml +++ b/input/grid5000/sites/grenoble/networks/gw-grenoble.yaml @@ -187,6 +187,8 @@ gw: snmp_pattern: "ethernet1/1/%PORT%" kavlan_pattern: "ethernet1/1/%PORT%" rate: 25000000000 + 81: servan-1 + 82: servan-2 83: uid: port-channel10 kind: channel diff --git a/lib/refrepo/net_names_mapping.yaml b/lib/refrepo/net_names_mapping.yaml index 97f0d21cc49a418bde5cd64c2365311b6a430a38..b79a5f65ad102eccff2745f7aa86571e7f87be06 100644 --- a/lib/refrepo/net_names_mapping.yaml +++ b/lib/refrepo/net_names_mapping.yaml @@ -186,6 +186,11 @@ pyxis: sagittaire: enp2s2f0: eth0 enp2s2f1: eth1 +servan: + eno33: eth0 + eno34: eth1 + eno35: eth2 + eno36: eth3 taurus: eno1: eth2 eno2: eth3