Mentions légales du service

Skip to content
Snippets Groups Projects
Commit c363ff21 authored by BERARD Benjamin's avatar BERARD Benjamin
Browse files

Merge branch 'testing' into 'master'

[grenoble/servan] Add initial configuration for servan

See merge request !336
parents 90ab4df7 cfa59c0c
Branches
No related tags found
1 merge request!336[grenoble/servan] Add initial configuration for servan
Pipeline #414754 passed
Showing
with 883 additions and 0 deletions
{
"architecture": {
"cpu_core_numbering": "contiguous-including-threads",
"nb_cores": 48,
"nb_procs": 2,
"nb_threads": 48,
"platform_type": "x86_64"
},
"bios": {
"release_date": "10/06/2021",
"vendor": "Dell Inc.",
"version": "2.5.6"
},
"bmc_version": "5.10",
"chassis": {
"manufacturer": "Dell Inc.",
"name": "PowerEdge R7525",
"serial": "CK3R3L3"
},
"exotic": true,
"main_memory": {
"ram_size": 137438953472
},
"management_tools": {
"bmc_vendor_tool": "ipmitool",
"ipmitool": {
"retries": 5
}
},
"memory_devices": [
{
"device": "dimm_a1",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a2",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a3",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a4",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b1",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b2",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b3",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b4",
"size": 17179869184,
"technology": "dram"
}
],
"network_adapters": [
{
"device": "eth0",
"driver": "ice",
"enabled": true,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"ip": "172.16.23.1",
"ip6": "2001:660:4406:100:8::1",
"kavlan": false,
"mac": "40:a6:b7:6b:1d:b0",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": true,
"mounted": true,
"name": "eno33",
"network_address": "servan-1.grenoble.grid5000.fr",
"rate": 25000000000,
"sriov": false,
"sriov_totalvfs": 0,
"switch": "gw",
"switch_port": "ethernet1/1/81:1",
"vendor": "Intel"
},
{
"device": "eth1",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:1d:b1",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno34",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "eth2",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:1d:b2",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno35",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "eth3",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:1d:b3",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno36",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "bmc",
"enabled": true,
"interface": "Ethernet",
"ip": "172.17.23.1",
"kavlan": false,
"mac": "b0:7b:25:f6:49:8e",
"management": true,
"mountable": false,
"mounted": false,
"network_address": "servan-1-bmc.grenoble.grid5000.fr"
}
],
"operating_system": {
"cstate_driver": "acpi_idle",
"cstate_governor": "menu",
"ht_enabled": false,
"pstate_driver": "acpi-cpufreq",
"pstate_governor": "performance",
"turboboost_enabled": true
},
"performance": {
"core_flops": 36800000000,
"node_flops": 1766400000000
},
"processor": {
"cache_l1": null,
"cache_l1d": 32768,
"cache_l1i": 32768,
"cache_l2": 524288,
"cache_l3": 16777216,
"clock_speed": 2300000000,
"ht_capable": true,
"instruction_set": "x86-64",
"microarchitecture": "Zen 2",
"microcode": "0x830104d",
"model": "AMD EPYC",
"other_description": "AMD EPYC 7352 24-Core Processor",
"vendor": "AMD",
"version": 7352
},
"software": {
"forced-deployment-timestamp": 202007300948,
"postinstall-version": "1.2022012700",
"standard-environment": "debian11-x64-std"
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/nvme-eui.36435430527023640025384100000003",
"by_path": "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1",
"id": "disk0",
"interface": "NVME",
"model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB",
"size": 1600321314816,
"storage": "SSD",
"vendor": "Dell"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.36435430527022630025384100000003",
"by_path": "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1",
"id": "disk1",
"interface": "NVME",
"model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB",
"size": 1600321314816,
"storage": "SSD",
"vendor": "Dell"
}
],
"supported_job_types": {
"besteffort": true,
"deploy": true,
"max_walltime": 0,
"queues": [
"admin",
"testing"
],
"virtual": "amd-v"
},
"type": "node",
"uid": "servan-1"
}
\ No newline at end of file
{
"architecture": {
"cpu_core_numbering": "contiguous-including-threads",
"nb_cores": 48,
"nb_procs": 2,
"nb_threads": 48,
"platform_type": "x86_64"
},
"bios": {
"release_date": "10/06/2021",
"vendor": "Dell Inc.",
"version": "2.5.6"
},
"bmc_version": "5.10",
"chassis": {
"manufacturer": "Dell Inc.",
"name": "PowerEdge R7525",
"serial": "BK3R3L3"
},
"exotic": true,
"main_memory": {
"ram_size": 137438953472
},
"management_tools": {
"bmc_vendor_tool": "ipmitool",
"ipmitool": {
"retries": 5
}
},
"memory_devices": [
{
"device": "dimm_a1",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a2",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a3",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_a4",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b1",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b2",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b3",
"size": 17179869184,
"technology": "dram"
},
{
"device": "dimm_b4",
"size": 17179869184,
"technology": "dram"
}
],
"network_adapters": [
{
"device": "eth0",
"driver": "ice",
"enabled": true,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"ip": "172.16.23.2",
"ip6": "2001:660:4406:100:8::2",
"kavlan": false,
"mac": "40:a6:b7:6b:13:40",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": true,
"mounted": true,
"name": "eno33",
"network_address": "servan-2.grenoble.grid5000.fr",
"rate": 25000000000,
"sriov": false,
"sriov_totalvfs": 0,
"switch": "gw",
"switch_port": "ethernet1/1/82:1",
"vendor": "Intel"
},
{
"device": "eth1",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:13:41",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno34",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "eth2",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:13:42",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno35",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "eth3",
"driver": "ice",
"enabled": false,
"firmware_version": "3.00 0x8000893f 20.5.13",
"interface": "Ethernet",
"kavlan": false,
"mac": "40:a6:b7:6b:13:43",
"management": false,
"model": "Ethernet Controller E810-C for SFP",
"mountable": false,
"mounted": false,
"name": "eno36",
"sriov": false,
"sriov_totalvfs": 0,
"vendor": "Intel"
},
{
"device": "bmc",
"enabled": true,
"interface": "Ethernet",
"ip": "172.17.23.2",
"kavlan": false,
"mac": "b0:7b:25:f6:40:a6",
"management": true,
"mountable": false,
"mounted": false,
"network_address": "servan-2-bmc.grenoble.grid5000.fr"
}
],
"operating_system": {
"cstate_driver": "acpi_idle",
"cstate_governor": "menu",
"ht_enabled": false,
"pstate_driver": "acpi-cpufreq",
"pstate_governor": "performance",
"turboboost_enabled": true
},
"performance": {
"core_flops": 36800000000,
"node_flops": 1766400000000
},
"processor": {
"cache_l1": null,
"cache_l1d": 32768,
"cache_l1i": 32768,
"cache_l2": 524288,
"cache_l3": 16777216,
"clock_speed": 2300000000,
"ht_capable": true,
"instruction_set": "x86-64",
"microarchitecture": "Zen 2",
"microcode": "0x830104d",
"model": "AMD EPYC",
"other_description": "AMD EPYC 7352 24-Core Processor",
"vendor": "AMD",
"version": 7352
},
"software": {
"forced-deployment-timestamp": 202007300948,
"postinstall-version": "1.2022012700",
"standard-environment": "debian11-x64-std"
},
"storage_devices": [
{
"by_id": "/dev/disk/by-id/nvme-eui.36435430527022550025384100000003",
"by_path": "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1",
"id": "disk0",
"interface": "NVME",
"model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB",
"size": 1600321314816,
"storage": "SSD",
"vendor": "Dell"
},
{
"by_id": "/dev/disk/by-id/nvme-eui.36435430527022640025384100000003",
"by_path": "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1",
"id": "disk1",
"interface": "NVME",
"model": "Dell Ent NVMe v2 AGN MU U.2 1.6TB",
"size": 1600321314816,
"storage": "SSD",
"vendor": "Dell"
}
],
"supported_job_types": {
"besteffort": true,
"deploy": true,
"max_walltime": 0,
"queues": [
"admin",
"testing"
],
"virtual": "amd-v"
},
"type": "node",
"uid": "servan-2"
}
\ No newline at end of file
{
"boot_type": "uefi",
"created_at": "Wed, 15 Dec 2021 00:00:00 GMT",
"exotic": true,
"kavlan": false,
"metrics": [
{
"description": "Input byte counter for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifacein_bytes_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Output byte counter for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifaceout_bytes_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Input packet counter for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifacein_packets_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Output packet counter for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifaceout_packets_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Input counter of discarded packets for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifacein_packets_discard_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Output counter of discarded packets for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifaceout_packets_discard_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Input counter of packet errors for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifacein_packets_error_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
},
{
"description": "Output counter of packet errors for the network device port",
"labels": {
"interface": "eth0"
},
"name": "network_ifaceout_packets_error_total",
"period": 15000,
"source": {
"protocol": "network_equipment"
}
}
],
"model": "Dell PowerEdge R7525",
"queues": [
"admin",
"testing"
],
"type": "cluster",
"uid": "servan"
}
\ No newline at end of file
...@@ -411,8 +411,16 @@ ...@@ -411,8 +411,16 @@
"uid": "troll-4" "uid": "troll-4"
}, },
{ {
"kind": "node",
"port": "eth0",
"snmp_name": "ethernet1/1/81:1",
"uid": "servan-1"
}, },
{ {
"kind": "node",
"port": "eth0",
"snmp_name": "ethernet1/1/82:1",
"uid": "servan-2"
}, },
{ {
"kind": "channel", "kind": "channel",
......
...@@ -96,6 +96,7 @@ disk_vendor_model_mapping: ...@@ -96,6 +96,7 @@ disk_vendor_model_mapping:
- Dell Express Flash NVMe PM1725 1.6TB AIC - Dell Express Flash NVMe PM1725 1.6TB AIC
- Dell Express Flash PM1725b 1.6TB AIC - Dell Express Flash PM1725b 1.6TB AIC
- Dell Ent NVMe AGN MU AIC 1.6TB - Dell Ent NVMe AGN MU AIC 1.6TB
- Dell Ent NVMe v2 AGN MU U.2 1.6TB
Samsung: Samsung:
- SAMSUNG MZ1LB1T9HALS-00007 - SAMSUNG MZ1LB1T9HALS-00007
Kioxia: Kioxia:
......
...@@ -14,6 +14,7 @@ ipv4: ...@@ -14,6 +14,7 @@ ipv4:
grenoble yeti eth0 0 0 3 0 grenoble yeti eth0 0 0 3 0
grenoble dahu eth0 0 0 4 0 grenoble dahu eth0 0 0 4 0
grenoble troll eth0 0 0 6 0 grenoble troll eth0 0 0 6 0
grenoble servan eth0 0 0 7 0
grenoble drac eth0 0 0 8 0 grenoble drac eth0 0 0 8 0
lille chifflot eth0 0 0 4 0 lille chifflot eth0 0 0 4 0
lille chifflot eth1 0 0 4 100 lille chifflot eth1 0 0 4 100
......
# Generated by g5k-checks (g5k-checks -m api)
---
servan-1:
architecture:
cpu_core_numbering: contiguous-including-threads
nb_cores: 48
nb_procs: 2
nb_threads: 48
platform_type: x86_64
bios:
release_date: 10/06/2021
vendor: Dell Inc.
version: 2.5.6
bmc_version: '5.10'
chassis:
manufacturer: Dell Inc.
name: PowerEdge R7525
serial: CK3R3L3
main_memory:
ram_size: 137438953472
memory_devices:
dimm_a1:
size: 17179869184
technology: dram
dimm_a2:
size: 17179869184
technology: dram
dimm_a3:
size: 17179869184
technology: dram
dimm_a4:
size: 17179869184
technology: dram
dimm_b1:
size: 17179869184
technology: dram
dimm_b2:
size: 17179869184
technology: dram
dimm_b3:
size: 17179869184
technology: dram
dimm_b4:
size: 17179869184
technology: dram
network_adapters:
bmc:
ip: 172.17.23.1
mac: b0:7b:25:f6:49:8e
management: true
eth0:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
ip: 172.16.23.1
mac: 40:a6:b7:6b:1d:b0
management: false
model: Ethernet Controller E810-C for SFP
name: eno33
rate: 25000000000
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth1:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:1d:b1
management: false
model: Ethernet Controller E810-C for SFP
name: eno34
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth2:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:1d:b2
management: false
model: Ethernet Controller E810-C for SFP
name: eno35
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth3:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:1d:b3
management: false
model: Ethernet Controller E810-C for SFP
name: eno36
sriov: false
sriov_totalvfs: 0
vendor: Intel
operating_system:
cstate_driver: acpi_idle
cstate_governor: menu
ht_enabled: false
pstate_driver: acpi-cpufreq
pstate_governor: performance
turboboost_enabled: true
processor:
cache_l1d: 32768
cache_l1i: 32768
cache_l2: 524288
cache_l3: 16777216
ht_capable: true
instruction_set: x86-64
microcode: '0x830104d'
model: AMD EPYC
other_description: AMD EPYC 7352 24-Core Processor
vendor: AMD
version: 7352
storage_devices:
pci-0000:c3:00.0-nvme-1:
by_id: "/dev/disk/by-id/nvme-eui.36435430527023640025384100000003"
by_path: "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1"
model: Dell Ent NVMe v2 AGN MU U.2 1.6TB
size: 1600321314816
storage: SSD
pci-0000:c4:00.0-nvme-1:
by_id: "/dev/disk/by-id/nvme-eui.36435430527022630025384100000003"
by_path: "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1"
model: Dell Ent NVMe v2 AGN MU U.2 1.6TB
size: 1600321314816
storage: SSD
supported_job_types:
virtual: amd-v
# Generated by g5k-checks (g5k-checks -m api)
---
servan-2:
architecture:
cpu_core_numbering: contiguous-including-threads
nb_cores: 48
nb_procs: 2
nb_threads: 48
platform_type: x86_64
bios:
release_date: 10/06/2021
vendor: Dell Inc.
version: 2.5.6
bmc_version: '5.10'
chassis:
manufacturer: Dell Inc.
name: PowerEdge R7525
serial: BK3R3L3
main_memory:
ram_size: 137438953472
memory_devices:
dimm_a1:
size: 17179869184
technology: dram
dimm_a2:
size: 17179869184
technology: dram
dimm_a3:
size: 17179869184
technology: dram
dimm_a4:
size: 17179869184
technology: dram
dimm_b1:
size: 17179869184
technology: dram
dimm_b2:
size: 17179869184
technology: dram
dimm_b3:
size: 17179869184
technology: dram
dimm_b4:
size: 17179869184
technology: dram
network_adapters:
bmc:
ip: 172.17.23.2
mac: b0:7b:25:f6:40:a6
management: true
eth0:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
ip: 172.16.23.2
mac: 40:a6:b7:6b:13:40
management: false
model: Ethernet Controller E810-C for SFP
name: eno33
rate: 25000000000
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth1:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:13:41
management: false
model: Ethernet Controller E810-C for SFP
name: eno34
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth2:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:13:42
management: false
model: Ethernet Controller E810-C for SFP
name: eno35
sriov: false
sriov_totalvfs: 0
vendor: Intel
eth3:
driver: ice
firmware_version: 3.00 0x8000893f 20.5.13
interface: Ethernet
mac: 40:a6:b7:6b:13:43
management: false
model: Ethernet Controller E810-C for SFP
name: eno36
sriov: false
sriov_totalvfs: 0
vendor: Intel
operating_system:
cstate_driver: acpi_idle
cstate_governor: menu
ht_enabled: false
pstate_driver: acpi-cpufreq
pstate_governor: performance
turboboost_enabled: true
processor:
cache_l1d: 32768
cache_l1i: 32768
cache_l2: 524288
cache_l3: 16777216
ht_capable: true
instruction_set: x86-64
microcode: '0x830104d'
model: AMD EPYC
other_description: AMD EPYC 7352 24-Core Processor
vendor: AMD
version: 7352
storage_devices:
pci-0000:c3:00.0-nvme-1:
by_id: "/dev/disk/by-id/nvme-eui.36435430527022550025384100000003"
by_path: "/dev/disk/by-path/pci-0000:c3:00.0-nvme-1"
model: Dell Ent NVMe v2 AGN MU U.2 1.6TB
size: 1600321314816
storage: SSD
pci-0000:c4:00.0-nvme-1:
by_id: "/dev/disk/by-id/nvme-eui.36435430527022640025384100000003"
by_path: "/dev/disk/by-path/pci-0000:c4:00.0-nvme-1"
model: Dell Ent NVMe v2 AGN MU U.2 1.6TB
size: 1600321314816
storage: SSD
supported_job_types:
virtual: amd-v
model: Dell PowerEdge R7525
created_at: 2021-12-15
kavlan: false
boot_type: uefi
exotic: true
queues:
- admin
- testing
nodes:
servan-[1-2]:
supported_job_types:
deploy: true
besteffort: true
max_walltime: 0
processor:
microarchitecture: Zen 2
clock_speed: 2300000000
software:
standard-environment: debian11-x64-std
network_adapters:
bmc:
interface: Ethernet
enabled: true
mountable: false
mounted: false
eth0:
enabled: true
mountable: true
mounted: true
eth1:
enabled: false
mountable: false
mounted: false
eth2:
enabled: false
mountable: false
mounted: false
eth3:
enabled: false
mountable: false
mounted: false
storage_devices:
pci-0000:c3:00.0-nvme-1:
interface: NVME
id: disk0
pci-0000:c4:00.0-nvme-1:
interface: NVME
id: disk1
...@@ -187,6 +187,8 @@ gw: ...@@ -187,6 +187,8 @@ gw:
snmp_pattern: "ethernet1/1/%PORT%" snmp_pattern: "ethernet1/1/%PORT%"
kavlan_pattern: "ethernet1/1/%PORT%" kavlan_pattern: "ethernet1/1/%PORT%"
rate: 25000000000 rate: 25000000000
81: servan-1
82: servan-2
83: 83:
uid: port-channel10 uid: port-channel10
kind: channel kind: channel
......
...@@ -186,6 +186,11 @@ pyxis: ...@@ -186,6 +186,11 @@ pyxis:
sagittaire: sagittaire:
enp2s2f0: eth0 enp2s2f0: eth0
enp2s2f1: eth1 enp2s2f1: eth1
servan:
eno33: eth0
eno34: eth1
eno35: eth2
eno36: eth3
taurus: taurus:
eno1: eth2 eno1: eth2
eno2: eth3 eno2: eth3
......
0% Loading or .