diff --git a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.yaml b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.yaml index a8bb4a68fec46bfc6622d58d60ff9e8c39456948..f4d66ce7195a5c2345817e638445eed10c78e60d 100644 --- a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.yaml +++ b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.yaml @@ -9,7 +9,7 @@ yeti-1: bios: release_date: 12/12/2017 vendor: Dell Inc. - version: 1.2.21 + version: 1.4.5 chassis: manufacturer: Dell Inc. name: PowerEdge R940 @@ -23,7 +23,7 @@ yeti-1: management: true eth0: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet ip: 172.16.19.1 mac: 24:6e:96:91:1e:b0 @@ -34,7 +34,7 @@ yeti-1: vendor: Intel eth1: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1e:b2 management: false @@ -43,7 +43,7 @@ yeti-1: vendor: Intel eth2: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1e:b4 management: false @@ -52,7 +52,7 @@ yeti-1: vendor: Intel eth3: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1e:b6 management: false @@ -83,28 +83,28 @@ yeti-1: sda: by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c00223ab220cfc3b8e0" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 479559942144 vendor: DELL sdb: by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc937c12e0d1b" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdc: by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93ac4f0fd93" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdd: by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93dc8e0d879" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL diff --git a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.yaml b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.yaml index 813d7c1b1b0bf454c458b8d63c8dd90192547e33..a761fee79fb32aa50c3f6756af2c58c60f0d8642 100644 --- a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.yaml +++ b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.yaml @@ -9,7 +9,7 @@ yeti-2: bios: release_date: 12/12/2017 vendor: Dell Inc. - version: 1.2.21 + version: 1.4.5 chassis: manufacturer: Dell Inc. name: PowerEdge R940 @@ -23,7 +23,7 @@ yeti-2: management: true eth0: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet ip: 172.16.19.2 mac: 24:6e:96:91:2b:50 @@ -34,7 +34,7 @@ yeti-2: vendor: Intel eth1: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:2b:52 management: false @@ -43,7 +43,7 @@ yeti-2: vendor: Intel eth2: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:2b:54 management: false @@ -52,7 +52,7 @@ yeti-2: vendor: Intel eth3: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:2b:56 management: false @@ -83,28 +83,28 @@ yeti-2: sda: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbc600223ab55ace7a0389" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 479559942144 vendor: DELL sdb: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc932bf99a770" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdc: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc935c34df088" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdd: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc937c74d2454" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL diff --git a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.yaml b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.yaml index 6c148f2aa8e5e64c855e9ba864096ff791d0501c..e1fe3d7be531e3afe56a67cc2f3337e6c8639b2c 100644 --- a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.yaml +++ b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.yaml @@ -9,7 +9,7 @@ yeti-3: bios: release_date: 12/12/2017 vendor: Dell Inc. - version: 1.2.21 + version: 1.4.5 chassis: manufacturer: Dell Inc. name: PowerEdge R940 @@ -23,7 +23,7 @@ yeti-3: management: true eth0: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet ip: 172.16.19.3 mac: 24:6e:96:91:4c:90 @@ -34,7 +34,7 @@ yeti-3: vendor: Intel eth1: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:4c:92 management: false @@ -43,7 +43,7 @@ yeti-3: vendor: Intel eth2: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:4c:94 management: false @@ -52,7 +52,7 @@ yeti-3: vendor: Intel eth3: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:4c:96 management: false @@ -81,28 +81,28 @@ yeti-3: version: Gold 6130 storage_devices: sda: - by_id: "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d7caa2ee25" + by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c00223ab220cfc3b8e0" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0" firmware_version: 5.0 model: PERC H740P Adp size: 479559942144 vendor: DELL sdb: - by_id: "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d9ccfeedee" + by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc937c12e0d1b" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0" firmware_version: 5.0 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdc: - by_id: "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92dbd095b1ac" + by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93ac4f0fd93" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0" firmware_version: 5.0 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdd: - by_id: "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92ded465c604" + by_id: "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93dc8e0d879" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0" firmware_version: 5.0 model: PERC H740P Adp diff --git a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.yaml b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.yaml index e56cf842268af34fc5f90c7027cc6f68c55c726e..d80e7e848d4846607e7361996bfa26f8042a53fe 100644 --- a/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.yaml +++ b/input/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.yaml @@ -9,7 +9,7 @@ yeti-4: bios: release_date: 12/12/2017 vendor: Dell Inc. - version: 1.2.21 + version: 1.4.5 chassis: manufacturer: Dell Inc. name: PowerEdge R940 @@ -23,7 +23,7 @@ yeti-4: management: true eth0: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet ip: 172.16.19.4 mac: 24:6e:96:91:1d:b0 @@ -34,7 +34,7 @@ yeti-4: vendor: Intel eth1: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1d:b2 management: false @@ -43,7 +43,7 @@ yeti-4: vendor: Intel eth2: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1d:b4 management: false @@ -52,7 +52,7 @@ yeti-4: vendor: Intel eth3: driver: i40e - firmware_version: 6.00 0x800034eb 18.3.6 + firmware_version: 6.00 0x80003750 18.5.17 interface: Ethernet mac: 24:6e:96:91:1d:b6 management: false @@ -83,28 +83,28 @@ yeti-4: sda: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbb700223ab55ccfde5c8a" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 479559942144 vendor: DELL sdb: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaecc8ec4a10" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdc: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf0ce536e29" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL sdd: by_id: "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf2d230b931" by_path: "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0" - firmware_version: 5.0 + firmware_version: 5.03 model: PERC H740P Adp size: 1999844147200 vendor: DELL