From bcde298a6344d9526c421f92ad9dc9a9382a3fac Mon Sep 17 00:00:00 2001 From: Saint-Marcel Frederic <frederic.saint-marcel@inria.fr> Date: Tue, 24 Apr 2018 14:39:36 +0200 Subject: [PATCH] [grenoble] regenerate yeti cluster reference API --- .../grenoble/clusters/yeti/nodes/yeti-1.json | 124 ++++- .../grenoble/clusters/yeti/nodes/yeti-2.json | 124 ++++- .../grenoble/clusters/yeti/nodes/yeti-3.json | 124 ++++- .../grenoble/clusters/yeti/nodes/yeti-4.json | 124 ++++- .../sites/grenoble/clusters/yeti/yeti.json | 4 +- grid5000-all.json | 500 +++++++++++++++++- .../sites/grenoble/clusters/yeti/yeti.yaml | 4 +- 7 files changed, 967 insertions(+), 37 deletions(-) diff --git a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.json b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.json index ec4588e48c1..35b851c30a8 100644 --- a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.json +++ b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-1.json @@ -1,11 +1,25 @@ { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGQSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -13,24 +27,126 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.1", "mac": "24:6e:96:91:1e:b0", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b2", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b4", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b6", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.1", - "mac": "50:9a:4c:76:71:1b" + "mac": "50:9a:4c:76:71:1b", + "management": true, + "network_address": "yeti-1-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c00223ab220cfc3b8e0", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc937c12e0d1b", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93ac4f0fd93", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93dc8e0d879", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-1" } \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.json b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.json index 3c4e8c65f18..a3425c2d668 100644 --- a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.json +++ b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-2.json @@ -1,11 +1,25 @@ { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGRSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -13,24 +27,126 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.2", "mac": "24:6e:96:91:2b:50", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:52", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:54", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:56", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.2", - "mac": "50:9a:4c:76:71:9f" + "mac": "50:9a:4c:76:71:9f", + "management": true, + "network_address": "yeti-2-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc600223ab55ace7a0389", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc932bf99a770", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc935c34df088", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc937c74d2454", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-2" } \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.json b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.json index ba3973aae32..edc91b8dda2 100644 --- a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.json +++ b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-3.json @@ -1,11 +1,25 @@ { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGPSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -13,24 +27,126 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.3", "mac": "24:6e:96:91:4c:90", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:92", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:94", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:96", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.3", - "mac": "50:9a:4c:76:72:89" + "mac": "50:9a:4c:76:72:89", + "management": true, + "network_address": "yeti-3-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d7caa2ee25", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d9ccfeedee", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92dbd095b1ac", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92ded465c604", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-3" } \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.json b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.json index 49f9d56a9ab..9f603b3ba3f 100644 --- a/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.json +++ b/data/grid5000/sites/grenoble/clusters/yeti/nodes/yeti-4.json @@ -1,11 +1,25 @@ { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGMSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -13,24 +27,126 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.4", "mac": "24:6e:96:91:1d:b0", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b2", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b4", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b6", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.4", - "mac": "50:9a:4c:74:5e:c4" + "mac": "50:9a:4c:74:5e:c4", + "management": true, + "network_address": "yeti-4-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb700223ab55ccfde5c8a", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaecc8ec4a10", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf0ce536e29", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf2d230b931", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-4" } \ No newline at end of file diff --git a/data/grid5000/sites/grenoble/clusters/yeti/yeti.json b/data/grid5000/sites/grenoble/clusters/yeti/yeti.json index f0863f61f79..7b92cf94814 100644 --- a/data/grid5000/sites/grenoble/clusters/yeti/yeti.json +++ b/data/grid5000/sites/grenoble/clusters/yeti/yeti.json @@ -3,8 +3,8 @@ "kavlan": true, "model": "Dell R940", "queues": [ - "default", - "admin" + "admin", + "testing" ], "type": "cluster", "uid": "yeti" diff --git a/grid5000-all.json b/grid5000-all.json index 13b306cc375..fca39ff87fd 100644 --- a/grid5000-all.json +++ b/grid5000-all.json @@ -23237,13 +23237,27 @@ "model": "Dell R940", "nodes": { "yeti-1": { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGQSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -23251,35 +23265,151 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.1", "mac": "24:6e:96:91:1e:b0", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b2", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b4", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1e:b6", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.1", - "mac": "50:9a:4c:76:71:1b" + "mac": "50:9a:4c:76:71:1b", + "management": true, + "network_address": "yeti-1-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c00223ab220cfc3b8e0", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc937c12e0d1b", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93ac4f0fd93", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a09c0021fcc93dc8e0d879", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-1" }, "yeti-2": { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGRSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -23287,35 +23417,151 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.2", "mac": "24:6e:96:91:2b:50", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:52", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:54", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:2b:56", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.2", - "mac": "50:9a:4c:76:71:9f" + "mac": "50:9a:4c:76:71:9f", + "management": true, + "network_address": "yeti-2-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc600223ab55ace7a0389", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc932bf99a770", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc935c34df088", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbc60021fcc937c74d2454", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-2" }, "yeti-3": { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGPSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -23323,35 +23569,151 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.3", "mac": "24:6e:96:91:4c:90", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:92", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:94", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:4c:96", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.3", - "mac": "50:9a:4c:76:72:89" + "mac": "50:9a:4c:76:72:89", + "management": true, + "network_address": "yeti-3-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d7caa2ee25", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92d9ccfeedee", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92dbd095b1ac", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030a3cb00223b92ded465c604", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-3" }, "yeti-4": { + "architecture": { + "nb_cores": 64, + "nb_procs": 4, + "nb_threads": 128, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "12/12/2017", + "vendor": "Dell Inc.", + "version": "1.2.21" + }, "chassis": { - "serial": "TBD" + "manufacturer": "Dell Inc.", + "name": "PowerEdge R940", + "serial": "6FGMSM2" }, "gpu": { "gpu": false }, "main_memory": { + "ram_size": 824633720832 }, "monitoring": { "wattmeter": "false" @@ -23359,31 +23721,133 @@ "network_adapters": [ { "device": "eth0", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", "interface": "Ethernet", "ip": "172.16.19.4", "mac": "24:6e:96:91:1d:b0", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", "mounted": true, + "name": "eno113", + "rate": 10000000000, "switch": null, - "switch_port": null + "switch_port": null, + "vendor": "Intel" + }, + { + "device": "eth1", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b2", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno114", + "vendor": "Intel" + }, + { + "device": "eth2", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b4", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno115", + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "firmware_version": "6.00 0x800034eb 18.3.6", + "interface": "Ethernet", + "mac": "24:6e:96:91:1d:b6", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "name": "eno116", + "vendor": "Intel" }, { "device": "bmc", "ip": "172.17.19.4", - "mac": "50:9a:4c:74:5e:c4" + "mac": "50:9a:4c:74:5e:c4", + "management": true, + "network_address": "yeti-4-bmc.grenoble.grid5000.fr" } ], + "operating_system": { + "cstate_driver": "intel_idle", + "cstate_governor": "menu", + "cstate_max_id": null, + "ht_enabled": true, + "pstate_driver": "intel_pstate", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 1048576, + "cache_l3": 23068672, + "clock_speed": 2100000000, + "ht_capable": true, + "instruction_set": "x86-64", + "model": "Intel Xeon", + "other_description": "Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz", + "vendor": "Intel" + }, "sensors": { }, "storage_devices": [ - + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb700223ab55ccfde5c8a", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 479559942144, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaecc8ec4a10", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:1:0", + "device": "sdb", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf0ce536e29", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:2:0", + "device": "sdc", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x6d09466030bbb70021fcbaf2d230b931", + "by_path": "/dev/disk/by-path/pci-0000:18:00.0-scsi-0:2:3:0", + "device": "sdd", + "firmware_version": 5.0, + "model": "PERC H740P Adp", + "size": 1999844147200, + "vendor": "DELL" + } ], + "supported_job_types": { + "virtual": "ivt" + }, "type": "node", "uid": "yeti-4" } }, "queues": [ - "default", - "admin" + "admin", + "testing" ], "type": "cluster", "uid": "yeti" diff --git a/input/grid5000/sites/grenoble/clusters/yeti/yeti.yaml b/input/grid5000/sites/grenoble/clusters/yeti/yeti.yaml index 531219d8414..5c143e95ed7 100644 --- a/input/grid5000/sites/grenoble/clusters/yeti/yeti.yaml +++ b/input/grid5000/sites/grenoble/clusters/yeti/yeti.yaml @@ -2,8 +2,10 @@ model: Dell R940 created_at: 2018-01-16 15:00:00 GMT kavlan: true queues: - - default + #- default Only testing queue for now - admin + - testing + nodes: yeti-[1-4]: network_adapters: -- GitLab