diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/kinovis.json b/data/grid5000/sites/grenoble/clusters/kinovis/kinovis.json index d403c79524f1b4622c874a13bd161fc910f10287..f0eae252a44f4175167b98ceaf48c4eac67f37c0 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/kinovis.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/kinovis.json @@ -80,7 +80,7 @@ ], "model": "HPE Proliant DL380 Gen11", "nodes_count": 6, - "nodes_description": "2 CPUs Intel Xeon Gold 6442Y, 24 cores/CPU, 2 GPUs L40S, 256GB RAM, 1787GB SSD, 2 x 25Gb Ethernet, 1 x 100Gb Ethernet", + "nodes_description": "2 CPUs Intel Xeon Gold 6442Y, 24 cores/CPU, 2 GPUs L40S, 256GB RAM, 1787GB SSD, 7x7153GB SSD, 2 x 25Gb Ethernet, 1 x 100Gb Ethernet", "priority": 202506, "queues": [ "admin", diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.json index fa2b16016ae863750c6bda6c7b202c27bd9b594b..885eedbda6c9e5fc9bc6ade60810ae905da70c71 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70139644d240d3", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70137f23480aca", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701369019b8d5f", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701355e461eb09", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701342c6e663e7", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70132aa31ba328", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701161fb3c655f", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.json index fa1f1dfd17e4272c57c293f1eeb59c0d5730a685..847e1707fe818e5daa5d189049d05e0cc0552221 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70148dab1e4574", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7014788c0ff482", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7014575b2450b7", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70142e1dd8a510", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7013f5c95aca59", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7013bc75157feb", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70118324d5cefd", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.json index ac4489d9642f6cab23212bd7b6c5b1777182b8d9..3323dde9ba75f5e577021cb4a0beda3c83868c6f 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f70130d7c514a16", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012fb61266bd1", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012e64233805d", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012d224128b94", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012be06850e90", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012a6e2548462", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f701141cda436ba", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.json index bb55b2969f1a9b6094a1bc4ad2dc299fc9d9199d..9d120162e1f7a8aa5fb0bb2d537e75f109c3316b 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f701f0f3ad0be25", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f70167367a31e4a", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f701622ed90bc70", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015f2a63a0528", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015dd87cc6d7f", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015c867900d75", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015ad3fdc4647", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.json index a05c677b776ea5462a1f4153cdb95a2c4f1d770a..6e7cc2fb0d33a9a363f82c7f3572e7bb140d24b2 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f7012557359bb8a", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f70123d50a15613", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f7012262d705d06", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f70120f0c06677d", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f7011f7e71e048a", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f7011dabc2ca91b", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc35c002f701114950b7f81", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.json b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.json index c06627b082e62b3f6a4e1dc247334aa7204861b4..01be30f892c025454aed5dfa47665946c6327c2f 100644 --- a/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.json +++ b/data/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.json @@ -370,6 +370,83 @@ "size": 1919816826880, "storage": "SSD", "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd4b8f38dcda", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0", + "firmware_version": 5.28, + "id": "disk1", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd3c78e70b93", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0", + "firmware_version": 5.28, + "id": "disk2", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd2d6134d200", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0", + "firmware_version": 5.28, + "id": "disk3", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd1e4be70241", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0", + "firmware_version": 5.28, + "id": "disk4", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd0e34427d88", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0", + "firmware_version": 5.28, + "id": "disk5", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffcfe1b1ffa00", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0", + "firmware_version": 5.28, + "id": "disk6", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffce5f6fa70bd", + "by_path": "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0", + "firmware_version": 5.28, + "id": "disk7", + "interface": "RAID", + "model": "MR416i-o Gen11", + "size": 7680945029120, + "storage": "SSD", + "vendor": "HPE" } ], "supported_job_types": { diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/kinovis.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/kinovis.yaml index d9530e4ef149ea06ad0ea0b0990ee18aa2e2c900..b4c77b687760518ef8d401095ad68e5a6bf0c587 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/kinovis.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/kinovis.yaml @@ -41,6 +41,27 @@ nodes: pci-0000:3b:00.0-scsi-0:3:111:0: id: disk0 interface: SATA + pci-0000:3b:00.0-scsi-0:3:104:0: + id: disk1 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:105:0: + id: disk2 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:106:0: + id: disk3 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:107:0: + id: disk4 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:108:0: + id: disk5 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:109:0: + id: disk6 + interface: RAID + pci-0000:3b:00.0-scsi-0:3:110:0: + id: disk7 + interface: RAID software: standard-environment: debian11-x64-std management_tools: diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.yaml index 340a63479cf1be7cdbafc416cc5a62f62eaf07b9..66c6248fc673bd9d431a94f6ef289839a08ba931 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-1.yaml @@ -122,6 +122,55 @@ kinovis-1: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70139644d240d3" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70137f23480aca" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701369019b8d5f" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701355e461eb09" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701342c6e663e7" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f70132aa31ba328" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f701161fb3c655f" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf002f3c936fac9d9633" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0" diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.yaml index 82f642294df3f8886dd18425f8b25b05a4055c1b..8232940c5df7d6c8b451db19df59ed655dc0eca7 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-2.yaml @@ -122,6 +122,55 @@ kinovis-2: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70148dab1e4574" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7014788c0ff482" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7014575b2450b7" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70142e1dd8a510" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7013f5c95aca59" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f7013bc75157feb" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f70118324d5cefd" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc2cf802f3cbf290530f39e" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0" diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.yaml index f7ac7963f7ce554f9c00064eff5bd8b06f1a205a..c06aab24eace084151be1c97a0a66ee996d048a9 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-3.yaml @@ -122,6 +122,55 @@ kinovis-3: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f70130d7c514a16" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012fb61266bd1" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012e64233805d" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012d224128b94" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012be06850e90" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f7012a6e2548462" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f701141cda436ba" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc2c4c02f3cb5584d211ce5" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0" diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.yaml index 8aea196bf3e7c1f008ca9d545b93a1c7f2ab6ec4..c469a1e219beb627eae4e54c40335eb6004649ec 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-4.yaml @@ -122,6 +122,55 @@ kinovis-4: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f701f0f3ad0be25" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f70167367a31e4a" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f701622ed90bc70" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015f2a63a0528" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015dd87cc6d7f" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015c867900d75" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f7015ad3fdc4647" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc356c02f3cc27c40c7bf59" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0" diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.yaml index 525db775bdc12269a84a81ddaff55f35de178a3d..a8d780367fe231dc5c1413eecdf676a942e3b75f 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-5.yaml @@ -122,6 +122,55 @@ kinovis-5: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f7012557359bb8a" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f70123d50a15613" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f7012262d705d06" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f70120f0c06677d" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f7011f7e71e048a" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f7011dabc2ca91b" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f701114950b7f81" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc35c002f3cc4e9a0fdf96d" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0" diff --git a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.yaml b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.yaml index bb4183fd9fea50b32cdf93dfc04fb731cbe038e7..c5ce5a1a7189dfeb426f320a73e7a9e8df6ddb16 100644 --- a/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.yaml +++ b/input/grid5000/sites/grenoble/clusters/kinovis/nodes/kinovis-6.yaml @@ -122,6 +122,55 @@ kinovis-6: vendor: Intel version: Gold 6442Y storage_devices: + pci-0000:3b:00.0-scsi-0:3:104:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd4b8f38dcda" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:104:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:105:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd3c78e70b93" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:105:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:106:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd2d6134d200" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:106:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:107:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd1e4be70241" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:107:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:108:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffd0e34427d88" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:108:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:109:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffcfe1b1ffa00" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:109:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD + pci-0000:3b:00.0-scsi-0:3:110:0: + by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f6ffce5f6fa70bd" + by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:110:0" + firmware_version: 5.28 + model: MR416i-o Gen11 + size: 7680945029120 + storage: SSD pci-0000:3b:00.0-scsi-0:3:111:0: by_id: "/dev/disk/by-id/wwn-0x600062b21bc380402f3cc4f1a1603fb2" by_path: "/dev/disk/by-path/pci-0000:3b:00.0-scsi-0:3:111:0"