diff --git a/data/grid5000/sites/rennes/clusters/abacus18/abacus18.json b/data/grid5000/sites/rennes/clusters/abacus18/abacus18.json new file mode 100644 index 0000000000000000000000000000000000000000..d1e66696372e0f2dedff0ac8c3c94a62cdc6f0d5 --- /dev/null +++ b/data/grid5000/sites/rennes/clusters/abacus18/abacus18.json @@ -0,0 +1,16 @@ +{ + "boot_type": "bios", + "created_at": "Wed, 11 Oct 2023 00:00:00 GMT", + "exotic": false, + "kavlan": false, + "metrics": [ + + ], + "model": "PowerEdge R7525", + "queues": [ + "admin", + "testing" + ], + "type": "cluster", + "uid": "abacus18" +} \ No newline at end of file diff --git a/data/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.json b/data/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.json new file mode 100644 index 0000000000000000000000000000000000000000..9ea78b601c73bf1bc58d329a7e9e4e6b595cfadd --- /dev/null +++ b/data/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.json @@ -0,0 +1,322 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 96, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "07/27/2020", + "vendor": "Dell Inc.", + "version": "1.5.5" + }, + "bmc_version": "4.30.30.30", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "4RK8T73" + }, + "exotic": false, + "gpu_devices": { + "nvidia0": { + "compute_capability": "7.5", + "cores": 4608, + "cpu_affinity": 0, + "device": "/dev/nvidia0", + "memory": 23800578048, + "microarchitecture": "Turing", + "model": "Quadro RTX 6000", + "performance": { + "fp-16": 32620000000000, + "fp-32": 16310000000000, + "fp-64": 510000000000 + }, + "power_default_limit": "250.00 W", + "vbios_version": "90.02.4E.00.04", + "vendor": "Nvidia" + }, + "nvidia1": { + "compute_capability": "7.5", + "cores": 4608, + "cpu_affinity": 1, + "device": "/dev/nvidia1", + "memory": 23800578048, + "microarchitecture": "Turing", + "model": "Quadro RTX 6000", + "performance": { + "fp-16": 32620000000000, + "fp-32": 16310000000000, + "fp-64": 510000000000 + }, + "power_default_limit": "250.00 W", + "vbios_version": "90.02.4E.00.04", + "vendor": "Nvidia" + }, + "nvidia2": { + "compute_capability": "7.5", + "cores": 4608, + "cpu_affinity": 1, + "device": "/dev/nvidia2", + "memory": 23800578048, + "microarchitecture": "Turing", + "model": "Quadro RTX 6000", + "performance": { + "fp-16": 32620000000000, + "fp-32": 16310000000000, + "fp-64": 510000000000 + }, + "power_default_limit": "250.00 W", + "vbios_version": "90.02.4E.00.04", + "vendor": "Nvidia" + } + }, + "main_memory": { + "ram_size": 274877906944 + }, + "management_tools": { + "bmc_vendor_tool": "racadm", + "ipmitool": { + "retries": 5 + } + }, + "memory_devices": [ + { + "device": "dimm_a1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a4", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a5", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a6", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a7", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_a8", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b1", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b2", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b3", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b4", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b5", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b6", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b7", + "size": 17179869184, + "technology": "dram" + }, + { + "device": "dimm_b8", + "size": 17179869184, + "technology": "dram" + } + ], + "network_adapters": [ + { + "device": "eth0", + "driver": "tg3", + "enabled": true, + "firmware_version": "FFV21.60.16 bc 5720-v1.39", + "interface": "Ethernet", + "ip": "172.16.109.18", + "ip6": "2001:660:4406:700:e::12", + "kavlan": false, + "mac": "f4:02:70:b9:60:4e", + "management": false, + "model": "NetXtreme BCM5720 2-port Gigabit Ethernet PCIe", + "mountable": true, + "mounted": true, + "name": "enp225s0f0", + "network_address": "abacus18-1.rennes.grid5000.fr", + "rate": 1000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": null, + "switch_port": null, + "vendor": "Broadcom Inc. and subsidiaries" + }, + { + "device": "eth1", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.60.16 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "f4:02:70:b9:60:4f", + "management": false, + "model": "NetXtreme BCM5720 2-port Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "enp225s0f1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom Inc. and subsidiaries" + }, + { + "device": "eth2", + "driver": "i40e", + "enabled": false, + "firmware_version": "7.10 0x800075e2 19.5.12", + "interface": "Ethernet", + "kavlan": false, + "mac": "68:05:ca:ce:a4:b0", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "mountable": false, + "mounted": false, + "name": "enp99s0f0", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "eth3", + "driver": "i40e", + "enabled": false, + "firmware_version": "7.10 0x800075e2 19.5.12", + "interface": "Ethernet", + "kavlan": false, + "mac": "68:05:ca:ce:a4:b1", + "management": false, + "model": "Ethernet Controller X710 for 10GbE SFP+", + "mountable": false, + "mounted": false, + "name": "enp99s0f1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Intel" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.109.18", + "kavlan": false, + "mac": "70:b5:e8:de:e4:08", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "abacus18-1-bmc.rennes.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": true, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 36800000000, + "node_flops": 1766400000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2300000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen 2", + "microcode": "0x830107a", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2023092008", + "standard-environment": "debian11-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x55cd2e4152708b36", + "by_path": "/dev/disk/by-path/pci-0000:41:00.0-ata-1", + "firmware_version": "XC31DL6R", + "id": "disk0", + "interface": "SATA", + "model": "SSDSCKKB240G8R", + "size": 240057409536, + "storage": "SSD", + "vendor": "Intel" + }, + { + "by_id": "/dev/disk/by-id/wwn-0x500a0751297f285c", + "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:0:0:0", + "firmware_version": "D1DF004", + "id": "disk1", + "interface": "SATA", + "model": "MTFDDAK960TDD", + "size": 960197124096, + "storage": "SSD", + "vendor": "Micron" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 0, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "abacus18-1" +} \ No newline at end of file diff --git a/input/grid5000/disks.yaml b/input/grid5000/disks.yaml index 7098908692302d658cbc3b624cba42d8d4f0b710..3af5b0fd34cd0356bdaefc520e7793dac7346438 100644 --- a/input/grid5000/disks.yaml +++ b/input/grid5000/disks.yaml @@ -60,6 +60,7 @@ disk_vendor_model_mapping: - MO000960RXRQK SATA: Intel: + - SSDSCKKB240G8R - SSDSC2KG480G7R - SSDSC2KG480G8R - SSDSC2KG960G8R @@ -73,6 +74,7 @@ disk_vendor_model_mapping: - VK000960GXNZB Micron: - MTFDDAK480TDN + - MTFDDAK960TDD - MTFDDAK960TDN - MTFDDAK960TDT Samsung: diff --git a/input/grid5000/ipv4.yaml b/input/grid5000/ipv4.yaml index d0b0de7f74396e5f0d5f156e1f54900fac3a2ff0..b68b1e93e3319056028b749f4481b73497d3fe98 100644 --- a/input/grid5000/ipv4.yaml +++ b/input/grid5000/ipv4.yaml @@ -69,6 +69,7 @@ ipv4: rennes paravance eth1 0 0 0 100 rennes parasilo eth0 0 0 1 0 rennes parasilo eth1 0 0 1 100 + rennes abacus18 eth0 0 0 13 17 rennes abacus20 eth0 0 0 13 19 rennes abacus25 eth0 0 0 13 24 rennes roazhon4 eth0 0 0 14 3 diff --git a/input/grid5000/sites/rennes/clusters/abacus18/abacus18.yaml b/input/grid5000/sites/rennes/clusters/abacus18/abacus18.yaml new file mode 100644 index 0000000000000000000000000000000000000000..aca1f486e4cb0e9963872ffcccced8c3a9b7b854 --- /dev/null +++ b/input/grid5000/sites/rennes/clusters/abacus18/abacus18.yaml @@ -0,0 +1,50 @@ +model: PowerEdge R7525 +created_at: 2023-10-11 +kavlan: false +boot_type: bios +exotic: false +queues: + - admin + - testing +nodes: + abacus18-1: + supported_job_types: + deploy: true + besteffort: true + max_walltime: 0 + processor: + microarchitecture: Zen 2 + clock_speed: 2300000000 + software: + standard-environment: debian11-x64-std + management_tools: + bmc_vendor_tool: racadm + network_adapters: + bmc: + interface: Ethernet + enabled: true + mountable: false + mounted: false + eth0: + enabled: true + mountable: true + mounted: true + eth1: + enabled: false + mountable: false + mounted: false + eth2: + enabled: false + mountable: false + mounted: false + eth3: + enabled: false + mountable: false + mounted: false + storage_devices: + pci-0000:41:00.0-ata-1: + id: disk0 + interface: SATA + pci-0000:01:00.0-scsi-0:0:0:0: + id: disk1 + interface: SATA diff --git a/input/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.yaml b/input/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.yaml new file mode 100644 index 0000000000000000000000000000000000000000..b6d218054ec30279b81a03802b48e8a1b0156add --- /dev/null +++ b/input/grid5000/sites/rennes/clusters/abacus18/nodes/abacus18-1.yaml @@ -0,0 +1,181 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +abacus18-1: + architecture: + cpu_core_numbering: contiguous + nb_cores: 48 + nb_procs: 2 + nb_threads: 96 + platform_type: x86_64 + bios: + release_date: 07/27/2020 + vendor: Dell Inc. + version: 1.5.5 + bmc_version: 4.30.30.30 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: 4RK8T73 + gpu_devices: + nvidia0: + cpu_affinity: 0 + device: "/dev/nvidia0" + memory: 23800578048 + model: Quadro RTX 6000 + power_default_limit: 250.00 W + vbios_version: 90.02.4E.00.04 + vendor: Nvidia + nvidia1: + cpu_affinity: 1 + device: "/dev/nvidia1" + memory: 23800578048 + model: Quadro RTX 6000 + power_default_limit: 250.00 W + vbios_version: 90.02.4E.00.04 + vendor: Nvidia + nvidia2: + cpu_affinity: 1 + device: "/dev/nvidia2" + memory: 23800578048 + model: Quadro RTX 6000 + power_default_limit: 250.00 W + vbios_version: 90.02.4E.00.04 + vendor: Nvidia + main_memory: + ram_size: 274877906944 + memory_devices: + dimm_a1: + size: 17179869184 + technology: dram + dimm_a2: + size: 17179869184 + technology: dram + dimm_a3: + size: 17179869184 + technology: dram + dimm_a4: + size: 17179869184 + technology: dram + dimm_a5: + size: 17179869184 + technology: dram + dimm_a6: + size: 17179869184 + technology: dram + dimm_a7: + size: 17179869184 + technology: dram + dimm_a8: + size: 17179869184 + technology: dram + dimm_b1: + size: 17179869184 + technology: dram + dimm_b2: + size: 17179869184 + technology: dram + dimm_b3: + size: 17179869184 + technology: dram + dimm_b4: + size: 17179869184 + technology: dram + dimm_b5: + size: 17179869184 + technology: dram + dimm_b6: + size: 17179869184 + technology: dram + dimm_b7: + size: 17179869184 + technology: dram + dimm_b8: + size: 17179869184 + technology: dram + network_adapters: + bmc: + ip: 172.17.109.18 + mac: 70:b5:e8:de:e4:08 + management: true + eth0: + driver: tg3 + firmware_version: FFV21.60.16 bc 5720-v1.39 + interface: Ethernet + ip: 172.16.109.18 + mac: f4:02:70:b9:60:4e + management: false + model: NetXtreme BCM5720 2-port Gigabit Ethernet PCIe + name: enp225s0f0 + rate: 1000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom Inc. and subsidiaries + eth1: + driver: tg3 + firmware_version: FFV21.60.16 bc 5720-v1.39 + interface: Ethernet + mac: f4:02:70:b9:60:4f + management: false + model: NetXtreme BCM5720 2-port Gigabit Ethernet PCIe + name: enp225s0f1 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom Inc. and subsidiaries + eth2: + driver: i40e + firmware_version: 7.10 0x800075e2 19.5.12 + interface: Ethernet + mac: 68:05:ca:ce:a4:b0 + management: false + model: Ethernet Controller X710 for 10GbE SFP+ + name: enp99s0f0 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + eth3: + driver: i40e + firmware_version: 7.10 0x800075e2 19.5.12 + interface: Ethernet + mac: 68:05:ca:ce:a4:b1 + management: false + model: Ethernet Controller X710 for 10GbE SFP+ + name: enp99s0f1 + sriov: false + sriov_totalvfs: 0 + vendor: Intel + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: true + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830107a' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + pci-0000:01:00.0-scsi-0:0:0:0: + by_id: "/dev/disk/by-id/wwn-0x500a0751297f285c" + by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:0:0:0" + firmware_version: D1DF004 + model: MTFDDAK960TDD + size: 960197124096 + storage: SSD + pci-0000:41:00.0-ata-1: + by_id: "/dev/disk/by-id/wwn-0x55cd2e4152708b36" + by_path: "/dev/disk/by-path/pci-0000:41:00.0-ata-1" + firmware_version: XC31DL6R + model: SSDSCKKB240G8R + size: 240057409536 + storage: SSD + supported_job_types: + virtual: amd-v diff --git a/lib/refrepo/net_names_mapping.yaml b/lib/refrepo/net_names_mapping.yaml index 3b018896f7aa3f07f274b15baaaac6454753f341..825f868aad2ef49f3b2c6459839fd62497380069 100644 --- a/lib/refrepo/net_names_mapping.yaml +++ b/lib/refrepo/net_names_mapping.yaml @@ -4,6 +4,11 @@ abacus20: eno2np1: eth1 enp137s0f0: eth2 enp137s0f1: eth3 +abacus18: + enp225s0f0: eth0 + enp225s0f1: eth1 + enp99s0f0: eth2 + enp99s0f1: eth3 abacus25: ens10f0: eth0 ens10f1: eth1