diff --git a/data/grid5000/sites/lyon/clusters/gemini/gemini.json b/data/grid5000/sites/lyon/clusters/gemini/gemini.json
index 03f6186d651624574734d5c8b8faa9ce60bb12a6..889b45a21beb241b9931d8c61280979cf940966b 100644
--- a/data/grid5000/sites/lyon/clusters/gemini/gemini.json
+++ b/data/grid5000/sites/lyon/clusters/gemini/gemini.json
@@ -1,6 +1,742 @@
 {
   "created_at": "Sun, 01 Sep 2019 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Power consumption reported by wattmetre, in watt",
+      "name": "wattmetre_power_watt",
+      "optional_period": 20,
+      "period": 1000,
+      "source": {
+        "protocol": "wattmetre"
+      }
+    },
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Front node ambiant temperature reported by BMC, in celsius",
+      "name": "bmc_temp_ambient_celsius",
+      "period": 5000,
+      "source": {
+        "id": 97,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of node reported by BMC, in watt",
+      "name": "bmc_power_node_watt",
+      "period": 5000,
+      "source": {
+        "id": 91,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 0 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu0_watt",
+      "period": 5000,
+      "source": {
+        "id": 83,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 1 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu1_watt",
+      "period": 5000,
+      "source": {
+        "id": 84,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 2 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu2_watt",
+      "period": 5000,
+      "source": {
+        "id": 85,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 3 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu3_watt",
+      "period": 5000,
+      "source": {
+        "id": 86,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 4 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu4_watt",
+      "period": 5000,
+      "source": {
+        "id": 87,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 5 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu5_watt",
+      "period": 5000,
+      "source": {
+        "id": 88,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 6 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu6_watt",
+      "period": 5000,
+      "source": {
+        "id": 89,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of GPU 7 reported by BMC, in watt by BMC, in watt",
+      "name": "bmc_power_gpgpu7_watt",
+      "period": 5000,
+      "source": {
+        "id": 90,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Airflow reported by BMC, in CFM",
+      "name": "bmc_airflow_cfm",
+      "period": 5000,
+      "source": {
+        "id": 2,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 0_1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan01_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 18,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 0_2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan02_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 19,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 1_1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan11_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 20,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 1_2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan12_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 21,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 2_1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan21_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 22,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 2_2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan22_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 23,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 3_1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan31_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 24,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of SYS fan 3_2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_sysfan32_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 25,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of HSC0 reported by BMC, in watt",
+      "name": "bmc_power_hsc0_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 48,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of HSC1 reported by BMC, in watt",
+      "name": "bmc_power_hsc1_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 51,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of HSC2 reported by BMC, in watt",
+      "name": "bmc_power_hsc2_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 53,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of PSU1 reported by BMC, in watt",
+      "name": "bmc_power_psu1_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 74,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of PSU2 reported by BMC, in watt",
+      "name": "bmc_power_psu2_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 76,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of PSU3 reported by BMC, in watt",
+      "name": "bmc_power_psu3_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 78,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of PSU4 reported by BMC, in watt",
+      "name": "bmc_power_psu4_watt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 80,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of BP0 reported by BMC, in celsius",
+      "name": "bmc_temp_ambient_bp0_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 95,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of BP1 reported by BMC, in celsius",
+      "name": "bmc_temp_ambient_bp1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 96,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of PCI reported by BMC, in celsius",
+      "name": "bmc_temp_ambient_pci_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 98,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 1 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 99,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 2 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 100,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM_AB reported by BMC, in celsius",
+      "name": "bmc_temp_dimm_ab_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 101,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM_CD reported by BMC, in celsius",
+      "name": "bmc_temp_dimm_cd_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 102,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM_EF reported by BMC, in celsius",
+      "name": "bmc_temp_dimm_ef_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 103,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM_GH reported by BMC, in celsius",
+      "name": "bmc_temp_dimm_gh_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 104,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of EXPB reported by BMC, in celsius",
+      "name": "bmc_temp_expb_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 105,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU0 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu0_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 106,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU1 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 107,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU2 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 108,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU3 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu3_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 109,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU4 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu4_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 110,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU5 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu5_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 111,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU6 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu6_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 112,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU7 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu7_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 113,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU B0 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu_b0_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 114,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of GPU B1 reported by BMC, in celsius",
+      "name": "bmc_temp_gpu_b1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 115,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of Inlet MB reported by BMC, in celsius",
+      "name": "bmc_temp_inlet_mb_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 116,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of OCP Mezz reported by BMC, in celsius",
+      "name": "bmc_temp_ocp_mezz_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 117,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of Outlet reported by BMC, in celsius",
+      "name": "bmc_temp_outlet_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 118,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of PCH reported by BMC, in celsius",
+      "name": "bmc_temp_pch_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 119,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of PDB reported by BMC, in celsius",
+      "name": "bmc_temp_pdb_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 120,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of Raid Card reported by BMC, in celsius",
+      "name": "bmc_temp_raidcard_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 121,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR CPU 1 reported by BMC, in celsius",
+      "name": "bmc_temp_vr_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 122,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR CPU 2 reported by BMC, in celsius",
+      "name": "bmc_temp_vr_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 123,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR DIMM_AB reported by BMC, in celsius",
+      "name": "bmc_temp_vr_dimm_ab_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 124,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR DIMM_CD reported by BMC, in celsius",
+      "name": "bmc_temp_vr_dimm_cd_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 125,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR DIMM_EF reported by BMC, in celsius",
+      "name": "bmc_temp_vr_dimm_ef_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 126,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of VR DIMM_GH reported by BMC, in celsius",
+      "name": "bmc_temp_vr_dimm_gh_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 127,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P12V reported by BMC, in volt",
+      "name": "bmc_voltage_p12v_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 128,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P1V05 reported by BMC, in volt",
+      "name": "bmc_voltage_p1v05_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 129,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P1V8_AUX reported by BMC, in volt",
+      "name": "bmc_voltage_p1v8_aux_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 130,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P3V3 reported by BMC, in volt",
+      "name": "bmc_voltage_p3v3_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 131,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P3V3_AUX reported by BMC, in volt",
+      "name": "bmc_voltage_p3v3_aux_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 132,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P3V_BAT reported by BMC, in volt",
+      "name": "bmc_voltage_p3v_bat_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 133,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P5V reported by BMC, in volt",
+      "name": "bmc_voltage_p5v_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 134,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of P5V_AUX reported by BMC, in volt",
+      "name": "bmc_voltage_p5v_aux_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 135,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR CPU1 reported by BMC, in volt",
+      "name": "bmc_voltage_vr_cpu1_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 136,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR CPU2 reported by BMC, in volt",
+      "name": "bmc_voltage_vr_cpu1_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 137,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR DIMM_AB reported by BMC, in volt",
+      "name": "bmc_voltage_vr_dimm_ab_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 138,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR DIMM_CD reported by BMC, in volt",
+      "name": "bmc_voltage_vr_dimm_cd_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 139,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR DIMM_EF reported by BMC, in volt",
+      "name": "bmc_voltage_vr_dimm_ef_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 140,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of VR DIMM_GH reported by BMC, in volt",
+      "name": "bmc_voltage_vr_dimm_gh_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 141,
+        "protocol": "ipmisensor"
+      }
+    }
+  ],
   "model": "Nvidia DGX-1",
   "queues": [
     "default",
diff --git a/data/grid5000/sites/lyon/clusters/hercule/hercule.json b/data/grid5000/sites/lyon/clusters/hercule/hercule.json
index 33b1ffcc5ca47c95afe013ac84aa2e5ef8809d86..f76d2a5d960ba33cfd7fd1ad43c28b77496d0781 100644
--- a/data/grid5000/sites/lyon/clusters/hercule/hercule.json
+++ b/data/grid5000/sites/lyon/clusters/hercule/hercule.json
@@ -1,6 +1,203 @@
 {
   "created_at": "Tue, 02 Oct 2012 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Front node ambiant temperature temperature reported by BMC, in celsius",
+      "name": "bmc_temp_ambiant_celsius",
+      "period": 5000,
+      "source": {
+        "id": 49,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "12V Standby voltage reported by BMC, in volt",
+      "name": "bmc_voltage_12vstandby_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 5,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "5V Standby voltage reported by BMC, in volt",
+      "name": "bmc_voltage_5vstandby_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 6,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "5V voltage reported by BMC, in volt",
+      "name": "bmc_voltage_5v_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 7,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "3.3V Standby voltage reported by BMC, in volt",
+      "name": "bmc_voltage_3.3vstandby_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 8,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "3.3V voltage reported by BMC, in volt",
+      "name": "bmc_voltage_3.3v_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 9,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of MEZZ1 reported by BMC, in celsius",
+      "name": "bmc_temp_mezz1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 11,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU1 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 12,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU2 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 13,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM ZONE 1 reported by BMC, in celsius",
+      "name": "bmc_temp_dimmzone1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 14,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of DIMM ZONE 2 reported by BMC, in celsius",
+      "name": "bmc_temp_dimmzone2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 15,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of PCH reported by BMC, in celsius",
+      "name": "bmc_temp_pch_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 18,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of input reported by BMC, in volt",
+      "name": "bmc_voltage_inputvoltage_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 51,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Current of input reported by BMC, in ampere",
+      "name": "bmc_current_inputcurrent_amp",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 52,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of fan 1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_fan_1_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 96,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of fan 2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_fan_2_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 97,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of fan 3 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_fan_3_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 98,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of fan 4 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_fan_4_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 99,
+        "protocol": "ipmisensor"
+      }
+    }
+  ],
   "model": "Dell PowerEdge C6220",
   "priority": "201299",
   "queues": [
diff --git a/data/grid5000/sites/lyon/clusters/nova/nova.json b/data/grid5000/sites/lyon/clusters/nova/nova.json
index f0cd7e24062b7069f6f0acd36786b273027fe2fa..5b86f8d32a70bc43db6272ee2ca37c31deb84deb 100644
--- a/data/grid5000/sites/lyon/clusters/nova/nova.json
+++ b/data/grid5000/sites/lyon/clusters/nova/nova.json
@@ -1,6 +1,162 @@
 {
   "created_at": "Thu, 01 Dec 2016 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Power consumption reported by wattmetre, in watt",
+      "name": "wattmetre_power_watt",
+      "optional_period": 20,
+      "period": 1000,
+      "source": {
+        "protocol": "wattmetre"
+      }
+    },
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Front node ambiant temperature temperature reported by BMC, in celsius",
+      "name": "bmc_temp_ambiant_celsius",
+      "period": 5000,
+      "source": {
+        "id": 23,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 1 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 155,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 2 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 156,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 2A reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan2a_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 13,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 2B reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan2b_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 14,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 3A reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan3a_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 15,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 3B reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan3b_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 16,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 4A reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan4a_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 17,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 4B reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan4b_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 18,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 5A reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan5a_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 19,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 5B reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan5b_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 20,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 6A reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan6a_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 21,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 6B reported by BMC, in RPM",
+      "name": "bmc_fanspeed_psufan6b_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 22,
+        "protocol": "ipmisensor"
+      }
+    }
+  ],
   "model": "Dell PowerEdge R430",
   "priority": "201700",
   "queues": [
diff --git a/data/grid5000/sites/lyon/clusters/orion/orion.json b/data/grid5000/sites/lyon/clusters/orion/orion.json
index 571b1ed31e8f2362006f758cb86c0fb19c2d4747..f050c1f8e9d29c501c1c8379fc725e6f9cc07d76 100644
--- a/data/grid5000/sites/lyon/clusters/orion/orion.json
+++ b/data/grid5000/sites/lyon/clusters/orion/orion.json
@@ -1,6 +1,181 @@
 {
   "created_at": "Fri, 14 Sep 2012 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Power consumption reported by wattmetre, in watt",
+      "name": "wattmetre_power_watt",
+      "optional_period": 20,
+      "period": 1000,
+      "source": {
+        "protocol": "wattmetre"
+      }
+    },
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Front node ambiant temperature reported by BMC, in celsius",
+      "name": "bmc_temp_ambiant_celsius",
+      "period": 5000,
+      "source": {
+        "id": 20,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption of node reported by BMC, in watt",
+      "name": "bmc_power_node_watt",
+      "period": 5000,
+      "source": {
+        "id": 95,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Current of PSU 1 reported by BMC, in ampere",
+      "name": "bmc_current_psu1_amp",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 88,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Current of PSU 2 reported by BMC, in ampere",
+      "name": "bmc_current_psu2_amp",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 89,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of PSU 1 reported by BMC, in volt",
+      "name": "bmc_voltage_psu1_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 90,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of PSU 2 reported by BMC, in volt",
+      "name": "bmc_voltage_psu2_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 91,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Exhausted air temperature reported by BMC, in celsius",
+      "name": "bmc_temp_exhaust_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 21,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 1 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 22,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 2 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 23,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan1_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 14,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan2_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 15,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 3 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan3_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 16,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 4 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan4_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 17,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 5 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan5_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 18,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 6 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan6_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 19,
+        "protocol": "ipmisensor"
+      }
+    }
+  ],
   "model": "Dell PowerEdge R720",
   "priority": "201299",
   "queues": [
diff --git a/data/grid5000/sites/lyon/clusters/sagittaire/sagittaire.json b/data/grid5000/sites/lyon/clusters/sagittaire/sagittaire.json
index dea4f1d88449d286fbc4ae194e674dd95b6997b5..3eecfe9d2cc0e3a625a2ab5365c21e91a0aaf14c 100644
--- a/data/grid5000/sites/lyon/clusters/sagittaire/sagittaire.json
+++ b/data/grid5000/sites/lyon/clusters/sagittaire/sagittaire.json
@@ -1,6 +1,33 @@
 {
   "created_at": "Sat, 01 Jul 2006 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Power consumption reported by wattmetre, in watt",
+      "name": "wattmetre_power_watt",
+      "optional_period": 20,
+      "period": 1000,
+      "source": {
+        "protocol": "wattmetre"
+      }
+    },
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    }
+  ],
   "model": "Sun Fire V20z",
   "priority": "201899",
   "queues": [
diff --git a/data/grid5000/sites/lyon/clusters/taurus/taurus.json b/data/grid5000/sites/lyon/clusters/taurus/taurus.json
index 5df6f21b7517c253a6fc4e008cd7ea6954a59fc2..cd7768301a616187ff452f0826179c410b4bb959 100644
--- a/data/grid5000/sites/lyon/clusters/taurus/taurus.json
+++ b/data/grid5000/sites/lyon/clusters/taurus/taurus.json
@@ -1,6 +1,181 @@
 {
   "created_at": "Fri, 14 Sep 2012 00:00:00 GMT",
   "kavlan": true,
+  "metrics": [
+    {
+      "description": "Power consumption per node reported by wattmetre, in watt",
+      "name": "wattmetre_power_watt",
+      "optional_period": 20,
+      "period": 1000,
+      "source": {
+        "protocol": "wattmetre"
+      }
+    },
+    {
+      "description": "Input byte counter for the network device port connected to the node",
+      "name": "network_ifacein_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Output byte counter for the network device port connected to the node",
+      "name": "network_ifaceout_bytes_total",
+      "period": 1000,
+      "source": {
+        "protocol": "network_equipment"
+      }
+    },
+    {
+      "description": "Front node ambiant temperature temperature reported by BMC, in celsius",
+      "name": "bmc_temp_ambiant_celsius",
+      "period": 5000,
+      "source": {
+        "id": 20,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Power consumption reported by BMC, in watt",
+      "name": "bmc_power_node_watt",
+      "period": 5000,
+      "source": {
+        "id": 95,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Current of PSU 1 reported by BMC, in ampere",
+      "name": "bmc_current_psu1_amp",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 88,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Current of PSU 2 reported by BMC, in ampere",
+      "name": "bmc_current_psu2_amp",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 89,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of PSU 1 reported by BMC, in volt",
+      "name": "bmc_voltage_psu1_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 90,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Voltage of PSU 2 reported by BMC, in volt",
+      "name": "bmc_voltage_psu2_volt",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 91,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Exhausted air temperature reported by BMC, in celsius",
+      "name": "bmc_temp_exhaust_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 21,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 1 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu1_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 22,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Temperature of CPU 2 reported by BMC, in celsius",
+      "name": "bmc_temp_cpu2_celsius",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 23,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 1 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan1_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 14,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 2 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan2_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 15,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 3 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan3_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 16,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 4 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan4_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 17,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 5 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan5_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 18,
+        "protocol": "ipmisensor"
+      }
+    },
+    {
+      "description": "Speed of PSU fan 6 reported by BMC, in rpm",
+      "name": "bmc_fanspeed_psufan6_rpm",
+      "optional_period": 5000,
+      "period": 0,
+      "source": {
+        "id": 19,
+        "protocol": "ipmisensor"
+      }
+    }
+  ],
   "model": "Dell PowerEdge R720",
   "queues": [
     "default",
diff --git a/input/grid5000/sites/lyon/clusters/gemini/gemini_metrics.yaml b/input/grid5000/sites/lyon/clusters/gemini/gemini_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..189fd5f26e320e10444bad8e05981f755667b7d6
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/gemini/gemini_metrics.yaml
@@ -0,0 +1,586 @@
+metrics:
+
+- name: wattmetre_power_watt
+  description: Power consumption reported by wattmetre, in watt
+  period: 1000
+  optional_period: 20
+  source:
+    protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: Input byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: Output byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: bmc_temp_ambient_celsius
+  description: Front node ambiant temperature reported by BMC, in celsius
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 97 #Temp_Ambient_FP
+
+- name: bmc_power_node_watt
+  description: Power consumption of node reported by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 91 #Pwr_Node
+
+- name: bmc_power_gpgpu0_watt
+  description: Power consumption of GPU 0 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 83 #Power_GPGPU0
+
+- name: bmc_power_gpgpu1_watt
+  description: Power consumption of GPU 1 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 84 #Power_GPGPU1
+
+- name: bmc_power_gpgpu2_watt
+  description: Power consumption of GPU 2 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 85 #Power_GPGPU2
+
+- name: bmc_power_gpgpu3_watt
+  description: Power consumption of GPU 3 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 86 #Power_GPGPU3
+
+- name: bmc_power_gpgpu4_watt
+  description: Power consumption of GPU 4 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 87 #Power_GPGPU4
+
+- name: bmc_power_gpgpu5_watt
+  description: Power consumption of GPU 5 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 88 #Power_GPGPU5
+
+- name: bmc_power_gpgpu6_watt
+  description: Power consumption of GPU 6 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 89 #Power_GPGPU6
+
+- name: bmc_power_gpgpu7_watt
+  description: Power consumption of GPU 7 reported by BMC, in watt by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 90 #Power_GPGPU7
+
+- name: bmc_airflow_cfm
+  description: Airflow reported by BMC, in CFM
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 2 #Airflow
+
+- name: bmc_fanspeed_sysfan01_rpm
+  description: Speed of SYS fan 0_1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 18 #Fan_SYS0_1
+
+- name: bmc_fanspeed_sysfan02_rpm
+  description: Speed of SYS fan 0_2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 19 #Fan_SYS0_2
+
+- name: bmc_fanspeed_sysfan11_rpm
+  description: Speed of SYS fan 1_1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 20 #Fan_SYS1_1
+
+- name: bmc_fanspeed_sysfan12_rpm
+  description: Speed of SYS fan 1_2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 21 #Fan_SYS1_2
+
+- name: bmc_fanspeed_sysfan21_rpm
+  description: Speed of SYS fan 2_1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 22 #Fan_SYS2_1
+
+- name: bmc_fanspeed_sysfan22_rpm
+  description: Speed of SYS fan 2_2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 23 #Fan_SYS2_2
+
+- name: bmc_fanspeed_sysfan31_rpm
+  description: Speed of SYS fan 3_1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 24 #Fan_SYS3_1
+
+- name: bmc_fanspeed_sysfan32_rpm
+  description: Speed of SYS fan 3_2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 25 #Fan_SYS3_2
+
+- name: bmc_power_hsc0_watt
+  description: Power consumption of HSC0 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 48 #HSC0 Input
+
+- name: bmc_power_hsc1_watt
+  description: Power consumption of HSC1 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 51 #HSC1 Input
+
+- name: bmc_power_hsc2_watt
+  description: Power consumption of HSC2 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 53 #HSC2 Input
+
+- name: bmc_power_psu1_watt
+  description: Power consumption of PSU1 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 74 #PSU1 Input
+
+- name: bmc_power_psu2_watt
+  description: Power consumption of PSU2 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 76 #PSU2 Input
+
+- name: bmc_power_psu3_watt
+  description: Power consumption of PSU3 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 78 #PSU3 Input
+
+- name: bmc_power_psu4_watt
+  description: Power consumption of PSU4 reported by BMC, in watt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 80 #PSU4 Input
+
+- name: bmc_temp_ambient_bp0_celsius
+  description: Temperature of BP0 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 95 #Temp_Ambient_BP0
+
+- name: bmc_temp_ambient_bp1_celsius
+  description: Temperature of BP1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 96 #Temp_Ambient_BP1
+
+- name: bmc_temp_ambient_pci_celsius
+  description: Temperature of PCI reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 98 #Temp_Ambient_PCI
+
+- name: bmc_temp_cpu1_celsius
+  description: Temperature of CPU 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 99 #Temp_CPU0
+
+- name: bmc_temp_cpu2_celsius
+  description: Temperature of CPU 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 100 #Temp_CPU1
+
+- name: bmc_temp_dimm_ab_celsius
+  description: Temperature of DIMM_AB reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 101 #Temp_DIMM_AB
+
+- name: bmc_temp_dimm_cd_celsius
+  description: Temperature of DIMM_CD reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 102 #Temp_DIMM_CD
+
+- name: bmc_temp_dimm_ef_celsius
+  description: Temperature of DIMM_EF reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 103 #Temp_DIMM_EF
+
+- name: bmc_temp_dimm_gh_celsius
+  description: Temperature of DIMM_GH reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 104 #Temp_DIMM_GH
+
+- name: bmc_temp_expb_celsius
+  description: Temperature of EXPB reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 105 #Temp_EXPB
+
+- name: bmc_temp_gpu0_celsius
+  description: Temperature of GPU0 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 106 #Temp_GPGPU0
+
+- name: bmc_temp_gpu1_celsius
+  description: Temperature of GPU1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 107 #Temp_GPGPU1
+
+- name: bmc_temp_gpu2_celsius
+  description: Temperature of GPU2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 108 #Temp_GPGPU2
+
+- name: bmc_temp_gpu3_celsius
+  description: Temperature of GPU3 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 109 #Temp_GPGPU3
+
+- name: bmc_temp_gpu4_celsius
+  description: Temperature of GPU4 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 110 #Temp_GPGPU4
+
+- name: bmc_temp_gpu5_celsius
+  description: Temperature of GPU5 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 111 #Temp_GPGPU5
+
+- name: bmc_temp_gpu6_celsius
+  description: Temperature of GPU6 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 112 #Temp_GPGPU6
+
+- name: bmc_temp_gpu7_celsius
+  description: Temperature of GPU7 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 113 #Temp_GPGPU7
+
+- name: bmc_temp_gpu_b0_celsius
+  description: Temperature of GPU B0 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 114 #Temp_GPUB0
+
+- name: bmc_temp_gpu_b1_celsius
+  description: Temperature of GPU B1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 115 #Temp_GPUB1
+
+- name: bmc_temp_inlet_mb_celsius
+  description: Temperature of Inlet MB reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 116 #Temp_Inlet_MB
+
+- name: bmc_temp_ocp_mezz_celsius
+  description: Temperature of OCP Mezz reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 117 #Temp_OCP_Mezz
+
+- name: bmc_temp_outlet_celsius
+  description: Temperature of Outlet reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 118 #Temp_Outlet
+
+- name: bmc_temp_pch_celsius
+  description: Temperature of PCH reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 119 #Temp_PCH
+
+- name: bmc_temp_pdb_celsius
+  description: Temperature of PDB reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 120 #Temp_PDB
+
+- name: bmc_temp_raidcard_celsius
+  description: Temperature of Raid Card reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 121 #Temp_RaidCard
+
+- name: bmc_temp_vr_cpu1_celsius
+  description: Temperature of VR CPU 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 122 #Temp_VR_CPU0
+
+- name: bmc_temp_vr_cpu2_celsius
+  description: Temperature of VR CPU 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 123 #Temp_VR_CPU1
+
+- name: bmc_temp_vr_dimm_ab_celsius
+  description: Temperature of VR DIMM_AB reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 124 #Temp_VR_DIMM_AB
+
+- name: bmc_temp_vr_dimm_cd_celsius
+  description: Temperature of VR DIMM_CD reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 125 #Temp_VR_DIMM_CD
+
+- name: bmc_temp_vr_dimm_ef_celsius
+  description: Temperature of VR DIMM_EF reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 126 #Temp_VR_DIMM_EF
+
+- name: bmc_temp_vr_dimm_gh_celsius
+  description: Temperature of VR DIMM_GH reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 127 #Temp_VR_DIMM_GH
+
+- name: bmc_voltage_p12v_volt
+  description: Voltage of P12V reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 128 #Volt_P12V
+
+- name: bmc_voltage_p1v05_volt
+  description: Voltage of P1V05 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 129 #Volt_P1V05
+
+- name: bmc_voltage_p1v8_aux_volt
+  description: Voltage of P1V8_AUX reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 130 #Volt_P1V8_AUX
+
+- name: bmc_voltage_p3v3_volt
+  description: Voltage of P3V3 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 131 #Volt_P3V3
+
+- name: bmc_voltage_p3v3_aux_volt
+  description: Voltage of P3V3_AUX reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 132 #Volt_P3V3_AUX
+
+- name: bmc_voltage_p3v_bat_volt
+  description: Voltage of P3V_BAT reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 133 #Volt_P3V_BAT
+
+- name: bmc_voltage_p5v_volt
+  description: Voltage of P5V reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 134 #Volt_P5V
+
+- name: bmc_voltage_p5v_aux_volt
+  description: Voltage of P5V_AUX reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 135 #Volt_P5V_AUX
+
+- name: bmc_voltage_vr_cpu1_volt
+  description: Voltage of VR CPU1 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 136 #Volt_VR_CPU0
+
+- name: bmc_voltage_vr_cpu1_volt
+  description: Voltage of VR CPU2 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 137 #Volt_VR_CPU1
+
+- name: bmc_voltage_vr_dimm_ab_volt
+  description: Voltage of VR DIMM_AB reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 138 #Volt_VR_DIMM_AB
+
+- name: bmc_voltage_vr_dimm_cd_volt
+  description: Voltage of VR DIMM_CD reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 139 #Volt_VR_DIMM_CD
+
+- name: bmc_voltage_vr_dimm_ef_volt
+  description: Voltage of VR DIMM_EF reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 140 #Volt_VR_DIMM_EF
+
+- name: bmc_voltage_vr_dimm_gh_volt
+  description: Voltage of VR DIMM_GH reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 141 #Volt_VR_DIMM_GH
+
diff --git a/input/grid5000/sites/lyon/clusters/hercule/hercule_metrics.yaml b/input/grid5000/sites/lyon/clusters/hercule/hercule_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..e55e2362dc84849e54c66be79273a62f67b92463
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/hercule/hercule_metrics.yaml
@@ -0,0 +1,162 @@
+metrics:
+# - name: wattmetre_power_sharedchassis_watt
+#   description: "Power consumption of shared chassis reported by wattmetre, in watt"
+#   period: 1000
+#   optional_period: 20
+#   source:
+#     protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: "Input byte counter for the network device port connected to the node"
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: "Output byte counter for the network device port connected to the node"
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: bmc_temp_ambiant_celsius
+  description: Front node ambiant temperature temperature reported by BMC, in celsius
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 49 #Inlet Temp
+
+- name: bmc_voltage_12vstandby_volt
+  description: 12V Standby voltage reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 5 #12V Standby
+
+- name: bmc_voltage_5vstandby_volt
+  description: 5V Standby voltage reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 6 #5V Standby
+
+- name: bmc_voltage_5v_volt
+  description: 5V voltage reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 7 #5V
+
+- name: bmc_voltage_3.3vstandby_volt
+  description: 3.3V Standby voltage reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 8 #3.3V Standby
+
+- name: bmc_voltage_3.3v_volt
+  description: 3.3V voltage reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 9 #3.3V
+
+- name: bmc_temp_mezz1_celsius
+  description: Temperature of MEZZ1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 11 #MEZZ1 TEMP
+
+- name: bmc_temp_cpu1_celsius
+  description: Temperature of CPU1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 12 #CPU1 Temp
+
+- name: bmc_temp_cpu2_celsius
+  description: Temperature of CPU2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 13 #CPU2 Temp
+
+- name: bmc_temp_dimmzone1_celsius
+  description: Temperature of DIMM ZONE 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 14 #DIMM ZONE 1 Temp
+
+- name: bmc_temp_dimmzone2_celsius
+  description: Temperature of DIMM ZONE 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 15 #DIMM ZONE 2 Temp
+
+- name: bmc_temp_pch_celsius
+  description: Temperature of PCH reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 18 #PCH Temp
+
+- name: bmc_voltage_inputvoltage_volt
+  description: Voltage of input reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 51 #Input Voltage
+
+- name: bmc_current_inputcurrent_amp
+  description: Current of input reported by BMC, in ampere
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 52 #Input Current
+
+- name: bmc_fanspeed_fan_1_rpm
+  description: Speed of fan 1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 96 #FAN_1
+
+- name: bmc_fanspeed_fan_2_rpm
+  description: Speed of fan 2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 97 #FAN_2
+
+- name: bmc_fanspeed_fan_3_rpm
+  description: Speed of fan 3 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 98 #FAN_3
+
+- name: bmc_fanspeed_fan_4_rpm
+  description: Speed of fan 4 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 99 #FAN_4
diff --git a/input/grid5000/sites/lyon/clusters/nova/nova_metrics.yaml b/input/grid5000/sites/lyon/clusters/nova/nova_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..9a3ecb03e16d2afd2b9f51de0f55f63c6dae1977
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/nova/nova_metrics.yaml
@@ -0,0 +1,124 @@
+---
+metrics:
+
+- name: wattmetre_power_watt
+  description: Power consumption reported by wattmetre, in watt
+  period: 1000
+  optional_period: 20
+  source:
+    protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: Input byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: Output byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: bmc_temp_ambiant_celsius
+  description: Front node ambiant temperature temperature reported by BMC, in celsius
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 23 #Inlet Temp
+
+- name: bmc_temp_cpu1_celsius
+  description: Temperature of CPU 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 155 #Temp
+
+- name: bmc_temp_cpu2_celsius
+  description: Temperature of CPU 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 156 #Temp
+
+- name: bmc_fanspeed_psufan2a_rpm
+  description: Speed of PSU fan 2A reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 13 #Fan2A
+
+- name: bmc_fanspeed_psufan2b_rpm
+  description: Speed of PSU fan 2B reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 14 #Fan2B
+
+- name: bmc_fanspeed_psufan3a_rpm
+  description: Speed of PSU fan 3A reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 15 #Fan3A
+
+- name: bmc_fanspeed_psufan3b_rpm
+  description: Speed of PSU fan 3B reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 16 #Fan3B
+
+- name: bmc_fanspeed_psufan4a_rpm
+  description: Speed of PSU fan 4A reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 17 #Fan4A
+
+- name: bmc_fanspeed_psufan4b_rpm
+  description: Speed of PSU fan 4B reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 18 #Fan4B
+
+- name: bmc_fanspeed_psufan5a_rpm
+  description: Speed of PSU fan 5A reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 19 #Fan5A
+
+- name: bmc_fanspeed_psufan5b_rpm
+  description: Speed of PSU fan 5B reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 20 #Fan5B
+
+- name: bmc_fanspeed_psufan6a_rpm
+  description: Speed of PSU fan 6A reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 21 #Fan6A
+
+- name: bmc_fanspeed_psufan6b_rpm
+  description: Speed of PSU fan 6B reported by BMC, in RPM
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 22 #Fan6B
diff --git a/input/grid5000/sites/lyon/clusters/orion/orion_metrics.yaml b/input/grid5000/sites/lyon/clusters/orion/orion_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..9b14c79c4cd2d55ef931a1cf522d937048b0e89d
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/orion/orion_metrics.yaml
@@ -0,0 +1,139 @@
+metrics:
+
+- name: wattmetre_power_watt
+  description: Power consumption reported by wattmetre, in watt
+  period: 1000
+  optional_period: 20
+  source:
+    protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: Input byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: Output byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: bmc_temp_ambiant_celsius
+  description: Front node ambiant temperature reported by BMC, in celsius
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 20 #Inlet Temp
+
+- name: bmc_power_node_watt
+  description: Power consumption of node reported by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 95 #Pwr Consumption
+
+- name: bmc_current_psu1_amp
+  description: Current of PSU 1 reported by BMC, in ampere
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 88 #Current 1
+
+- name: bmc_current_psu2_amp
+  description: Current of PSU 2 reported by BMC, in ampere
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 89 #Current 2
+
+- name: bmc_voltage_psu1_volt
+  description: Voltage of PSU 1 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 90 #Voltage 1
+
+- name: bmc_voltage_psu2_volt
+  description: Voltage of PSU 2 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 91 #Voltage 2
+
+- name: bmc_temp_exhaust_celsius
+  description: Exhausted air temperature reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 21 #Exhaust Temp
+
+- name: bmc_temp_cpu1_celsius
+  description: Temperature of CPU 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 22 #Temp
+
+- name: bmc_temp_cpu2_celsius
+  description: Temperature of CPU 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 23 #Temp
+
+- name: bmc_fanspeed_psufan1_rpm
+  description: Speed of PSU fan 1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 14 #Fan1
+
+- name: bmc_fanspeed_psufan2_rpm
+  description: Speed of PSU fan 2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 15 #Fan2
+
+- name: bmc_fanspeed_psufan3_rpm
+  description: Speed of PSU fan 3 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 16 #Fan3
+
+- name: bmc_fanspeed_psufan4_rpm
+  description: Speed of PSU fan 4 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 17 #Fan4
+
+- name: bmc_fanspeed_psufan5_rpm
+  description: Speed of PSU fan 5 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 18 #Fan5
+
+- name: bmc_fanspeed_psufan6_rpm
+  description: Speed of PSU fan 6 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 19 #Fan6
+
diff --git a/input/grid5000/sites/lyon/clusters/sagittaire/sagittaire_metrics.yaml b/input/grid5000/sites/lyon/clusters/sagittaire/sagittaire_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..d915f595d08a1858d184439a12b409f93b2991ae
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/sagittaire/sagittaire_metrics.yaml
@@ -0,0 +1,21 @@
+metrics:
+
+- name: wattmetre_power_watt
+  description: "Power consumption reported by wattmetre, in watt"
+  period: 1000
+  optional_period: 20
+  source:
+    protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: "Input byte counter for the network device port connected to the node"
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: "Output byte counter for the network device port connected to the node"
+  period: 1000
+  source:
+    protocol: network_equipment
+
diff --git a/input/grid5000/sites/lyon/clusters/taurus/taurus_metrics.yaml b/input/grid5000/sites/lyon/clusters/taurus/taurus_metrics.yaml
new file mode 100644
index 0000000000000000000000000000000000000000..f016cbf703130541b277f6e6381080fa625c175b
--- /dev/null
+++ b/input/grid5000/sites/lyon/clusters/taurus/taurus_metrics.yaml
@@ -0,0 +1,139 @@
+---
+metrics:
+
+- name: wattmetre_power_watt
+  description: Power consumption per node reported by wattmetre, in watt
+  period: 1000
+  optional_period: 20
+  source:
+    protocol: wattmetre
+
+- name: network_ifacein_bytes_total
+  description: Input byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: network_ifaceout_bytes_total
+  description: Output byte counter for the network device port connected to the node
+  period: 1000
+  source:
+    protocol: network_equipment
+
+- name: bmc_temp_ambiant_celsius
+  description: Front node ambiant temperature temperature reported by BMC, in celsius
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 20 #Inlet Temp
+
+- name: bmc_power_node_watt
+  description: Power consumption reported by BMC, in watt
+  period: 5000
+  source:
+    protocol: ipmisensor
+    id: 95 #Pwr Consumption
+
+- name: bmc_current_psu1_amp
+  description: Current of PSU 1 reported by BMC, in ampere
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 88 #Current 1
+
+- name: bmc_current_psu2_amp
+  description: Current of PSU 2 reported by BMC, in ampere
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 89 #Current 2
+
+- name: bmc_voltage_psu1_volt
+  description: Voltage of PSU 1 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 90 #Voltage 1
+
+- name: bmc_voltage_psu2_volt
+  description: Voltage of PSU 2 reported by BMC, in volt
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 91 #Voltage 2
+
+- name: bmc_temp_exhaust_celsius
+  description: Exhausted air temperature reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 21 #Exhaust Temp
+
+- name: bmc_temp_cpu1_celsius
+  description: Temperature of CPU 1 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 22 #Temp
+
+- name: bmc_temp_cpu2_celsius
+  description: Temperature of CPU 2 reported by BMC, in celsius
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 23 #Temp
+
+- name: bmc_fanspeed_psufan1_rpm
+  description: Speed of PSU fan 1 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 14 #Fan1
+
+- name: bmc_fanspeed_psufan2_rpm
+  description: Speed of PSU fan 2 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 15 #Fan2
+
+- name: bmc_fanspeed_psufan3_rpm
+  description: Speed of PSU fan 3 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 16 #Fan3
+
+- name: bmc_fanspeed_psufan4_rpm
+  description: Speed of PSU fan 4 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 17 #Fan4
+
+- name: bmc_fanspeed_psufan5_rpm
+  description: Speed of PSU fan 5 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 18 #Fan5
+
+- name: bmc_fanspeed_psufan6_rpm
+  description: Speed of PSU fan 6 reported by BMC, in rpm
+  period: 0
+  optional_period: 5000
+  source:
+    protocol: ipmisensor
+    id: 19 #Fan6