Mentions légales du service

Skip to content
Snippets Groups Projects
Commit 3b9e0e4a authored by Lucas Nussbaum's avatar Lucas Nussbaum
Browse files

Merge branch 'testing-mercantour6' into 'master'

Testing mercantour6

See merge request !1057
parents 5d010e30 c852a5d9
No related branches found
No related tags found
1 merge request!1057Testing mercantour6
Pipeline #1126173 passed
Pipeline: Resources Explorer

#1126174

    {
    "boot_type": "bios",
    "created_at": "Thu, 27 Feb 2025 00:00:00 GMT",
    "exotic": false,
    "kavlan": false,
    "manufactured_at": "2020-10-05",
    "metrics": [
    {
    "description": "Default subset of metrics from Prometheus Node Exporter",
    "name": "prom_default_metrics",
    "optional_period": 15000,
    "period": 0,
    "source": {
    "id": [
    "node_boot_time_seconds",
    "node_cpu_scaling_frequency_hertz",
    "node_cpu_seconds_total",
    "node_filesystem_free_bytes",
    "node_filesystem_size_bytes",
    "node_load1",
    "node_load15",
    "node_load5",
    "node_memory_Buffers_bytes",
    "node_memory_Cached_bytes",
    "node_memory_MemAvailable_bytes",
    "node_memory_MemFree_bytes",
    "node_memory_MemTotal_bytes",
    "node_memory_Shmem_bytes",
    "node_memory_SwapFree_bytes",
    "node_memory_SwapTotal_bytes",
    "node_network_receive_bytes_total",
    "node_network_receive_packets_total",
    "node_network_transmit_bytes_total",
    "node_network_transmit_packets_total",
    "node_procs_blocked",
    "node_procs_running",
    "kwollect_custom"
    ],
    "port": 9100,
    "protocol": "prometheus"
    }
    },
    {
    "description": "All metrics from Prometheus Node Exporter",
    "name": "prom_all_metrics",
    "optional_period": 15000,
    "period": 0,
    "source": {
    "port": 9100,
    "protocol": "prometheus"
    }
    }
    ],
    "model": "Dell PowerEdge R7525",
    "nodes_count": 1,
    "nodes_description": "2 CPUs AMD EPYC 7542, 32 cores/CPU, 1024GB RAM, 223GB SSD, 1786GB SSD, 1 x 1Gb Ethernet, 1 x 40Gb InfiniBand",
    "priority": 202010,
    "queues": [
    "admin",
    "testing"
    ],
    "redfish": true,
    "type": "cluster",
    "uid": "mercantour6",
    "warranty_end": "2027-10-07"
    }
    \ No newline at end of file
    {
    "architecture": {
    "cpu_core_numbering": "contiguous",
    "nb_cores": 64,
    "nb_procs": 2,
    "nb_threads": 128,
    "platform_type": "x86_64"
    },
    "bios": {
    "release_date": "02/03/2025",
    "vendor": "Dell Inc.",
    "version": "2.18.1"
    },
    "bmc_version": "7.20.10.05",
    "chassis": {
    "manufactured_at": "2020-10-05",
    "manufacturer": "Dell Inc.",
    "name": "PowerEdge R7525",
    "serial": "425FY63",
    "warranty_end": "2027-10-07"
    },
    "exotic": false,
    "main_memory": {
    "ram_size": 1099511627776
    },
    "management_tools": {
    "bmc_vendor_tool": "racadm",
    "ipmitool": {
    "retries": 5
    }
    },
    "memory_devices": [
    {
    "device": "dimm_a1",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a2",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a3",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a4",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a5",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a6",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a7",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_a8",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b1",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b2",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b3",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b4",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b5",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b6",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b7",
    "size": 68719476736,
    "technology": "dram"
    },
    {
    "device": "dimm_b8",
    "size": 68719476736,
    "technology": "dram"
    }
    ],
    "network_adapters": [
    {
    "device": "eth0",
    "driver": "tg3",
    "enabled": true,
    "firmware_version": "FFV23.11.4 bc 5720-v1.39",
    "interface": "Ethernet",
    "ip": "172.16.130.46",
    "ip6": "2001:660:4406:800:3::2e",
    "kavlan": false,
    "mac": "f4:02:70:b9:2b:b6",
    "management": false,
    "model": "NetXtreme BCM5720 2-port Gigabit Ethernet PCIe",
    "mountable": true,
    "mounted": true,
    "name": "eno1",
    "network_address": "mercantour6-1.sophia.grid5000.fr",
    "rate": 1000000000,
    "sriov": false,
    "sriov_totalvfs": 0,
    "switch": null,
    "switch_port": null,
    "vendor": "Broadcom Inc. and subsidiaries"
    },
    {
    "device": "eth1",
    "driver": "tg3",
    "enabled": false,
    "firmware_version": "FFV23.11.4 bc 5720-v1.39",
    "interface": "Ethernet",
    "kavlan": false,
    "mac": "f4:02:70:b9:2b:b7",
    "management": false,
    "model": "NetXtreme BCM5720 2-port Gigabit Ethernet PCIe",
    "mountable": false,
    "mounted": false,
    "name": "eno2",
    "sriov": false,
    "sriov_totalvfs": 0,
    "vendor": "Broadcom Inc. and subsidiaries"
    },
    {
    "device": "ib0",
    "driver": "mlx4_core",
    "enabled": true,
    "firmware_version": "2.42.5000",
    "guid": "0x043f72030017fd91",
    "interface": "InfiniBand",
    "ip": "172.18.130.46",
    "kavlan": false,
    "mac": "04:3f:72:03:00:17:fd:91",
    "management": false,
    "model": "MT27520 Family [ConnectX-3 Pro]",
    "mountable": true,
    "mounted": true,
    "name": "ib0",
    "netmask": "255.255.240.0",
    "network_address": "mercantour6-1-ib0.sophia.grid5000.fr",
    "rate": 40000000000,
    "vendor": "Mellanox Technologies"
    },
    {
    "device": "bmc",
    "enabled": true,
    "interface": "Ethernet",
    "ip": "172.17.130.46",
    "kavlan": false,
    "mac": "70:b5:e8:d7:6a:4a",
    "management": true,
    "mountable": false,
    "mounted": false,
    "network_address": "mercantour6-1-bmc.sophia.grid5000.fr"
    }
    ],
    "nodeset": "mercantour6",
    "operating_system": {
    "cstate_driver": "acpi_idle",
    "cstate_governor": "menu",
    "ht_enabled": true,
    "pstate_driver": "acpi-cpufreq",
    "pstate_governor": "performance",
    "turboboost_enabled": true
    },
    "performance": {
    "core_flops": 46400000000,
    "node_flops": 2969600000000
    },
    "processor": {
    "cache_l1": null,
    "cache_l1d": 32768,
    "cache_l1i": 32768,
    "cache_l2": 524288,
    "cache_l3": 16777216,
    "clock_speed": 2900000000,
    "ht_capable": true,
    "instruction_set": "x86-64",
    "microarchitecture": "Zen 2",
    "microcode": "0x830107d",
    "model": "AMD EPYC",
    "other_description": "AMD EPYC 7542 32-Core Processor",
    "vendor": "AMD",
    "version": 7542
    },
    "redfish": true,
    "software": {
    "forced-deployment-timestamp": 202007300948,
    "postinstall-version": "1.2025021810",
    "standard-environment": "debian11-x64-std"
    },
    "storage_devices": [
    {
    "by_id": "/dev/disk/by-id/wwn-0x670b5e80d622090027c144d0ef5cacdf",
    "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0",
    "firmware_version": 5.16,
    "id": "disk0",
    "interface": "RAID",
    "model": "PERC H745 Frnt",
    "size": 239444426752,
    "storage": "SSD",
    "vendor": "Dell"
    },
    {
    "by_id": "/dev/disk/by-id/wwn-0x670b5e80d622090027c149ae2f2d9cb4",
    "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:1:0",
    "firmware_version": 5.16,
    "id": "disk1",
    "interface": "RAID",
    "model": "PERC H745 Frnt",
    "size": 1918239768576,
    "storage": "SSD",
    "vendor": "Dell"
    }
    ],
    "supported_job_types": {
    "besteffort": true,
    "deploy": true,
    "max_walltime": 0,
    "queues": [
    "admin",
    "testing"
    ],
    "virtual": "amd-v"
    },
    "type": "node",
    "uid": "mercantour6-1"
    }
    \ No newline at end of file
    ...@@ -2244,6 +2244,12 @@ sites: ...@@ -2244,6 +2244,12 @@ sites:
    chassis: chassis:
    manufactured_at: 2015-09-02 manufactured_at: 2015-09-02
    warranty_end: 2020-09-02 warranty_end: 2020-09-02
    mercantour6:
    nodes:
    mercantour6-1:
    chassis:
    manufactured_at: 2020-10-05
    warranty_end: 2027-10-07
    uvb: uvb:
    nodes: nodes:
    uvb-10: uvb-10:
    ......
    ...@@ -14,6 +14,7 @@ disk_vendor_model_mapping: ...@@ -14,6 +14,7 @@ disk_vendor_model_mapping:
    - PERC H730P Mini - PERC H730P Mini
    - PERC H345 Front - PERC H345 Front
    - PERC H745P MX - PERC H745P MX
    - PERC H745 Frnt
    - PERC H740P Mini - PERC H740P Mini
    - DELLBOSS VD - DELLBOSS VD
    HPE: HPE:
    ......
    ...@@ -121,6 +121,7 @@ ipv4: ...@@ -121,6 +121,7 @@ ipv4:
    sophia mercantour4 eth0 0 0 2 40 sophia mercantour4 eth0 0 0 2 40
    sophia mercantour5 eth0 0 0 2 41 sophia mercantour5 eth0 0 0 2 41
    sophia mercantour6 eth0 0 0 2 45 sophia mercantour6 eth0 0 0 2 45
    sophia mercantour6 ib0 0 0 2 45
    sophia mercantour7 eth0 0 0 2 46 sophia mercantour7 eth0 0 0 2 46
    sophia esterel1 eth0 0 0 3 0 sophia esterel1 eth0 0 0 3 0
    sophia esterel2 eth0 0 0 3 1 sophia esterel2 eth0 0 0 3 1
    ......
    ---
    model: Dell PowerEdge R7525
    created_at: 2025-02-27
    kavlan: false
    boot_type: bios
    exotic: false
    queues:
    - admin
    - testing
    nodes:
    mercantour6-1:
    supported_job_types:
    deploy: true
    besteffort: true
    max_walltime: 0
    processor:
    microarchitecture: 'Zen 2'
    clock_speed: 2900000000
    network_adapters:
    bmc:
    interface: Ethernet
    enabled: true
    mountable: false
    mounted: false
    eth0:
    enabled: true
    mountable: true
    mounted: true
    eth1:
    enabled: false
    mountable: false
    mounted: false
    ib0:
    mounted: true
    enabled: true
    mountable: true
    netmask: 255.255.240.0
    storage_devices:
    pci-0000:01:00.0-scsi-0:2:0:0:
    id: disk0
    interface: RAID
    pci-0000:01:00.0-scsi-0:2:1:0:
    id: disk1
    interface: RAID
    software:
    standard-environment: debian11-x64-std
    management_tools:
    bmc_vendor_tool: racadm
    nodeset: mercantour6
    ---
    metrics:
    - name: prom_default_metrics
    description: Default subset of metrics from Prometheus Node Exporter
    period: 0
    optional_period: 15000
    source:
    protocol: prometheus
    port: 9100
    id:
    - node_boot_time_seconds
    - node_cpu_scaling_frequency_hertz
    - node_cpu_seconds_total
    - node_filesystem_free_bytes
    - node_filesystem_size_bytes
    - node_load1
    - node_load15
    - node_load5
    - node_memory_Buffers_bytes
    - node_memory_Cached_bytes
    - node_memory_MemAvailable_bytes
    - node_memory_MemFree_bytes
    - node_memory_MemTotal_bytes
    - node_memory_Shmem_bytes
    - node_memory_SwapFree_bytes
    - node_memory_SwapTotal_bytes
    - node_network_receive_bytes_total
    - node_network_receive_packets_total
    - node_network_transmit_bytes_total
    - node_network_transmit_packets_total
    - node_procs_blocked
    - node_procs_running
    - kwollect_custom
    - name: prom_all_metrics
    description: All metrics from Prometheus Node Exporter
    period: 0
    optional_period: 15000
    source:
    protocol: prometheus
    port: 9100
    # Generated by g5k-checks (g5k-checks -m api)
    ---
    mercantour6-1:
    architecture:
    cpu_core_numbering: contiguous
    nb_cores: 64
    nb_procs: 2
    nb_threads: 128
    platform_type: x86_64
    bios:
    release_date: 02/03/2025
    vendor: Dell Inc.
    version: 2.18.1
    bmc_version: 7.20.10.05
    chassis:
    manufacturer: Dell Inc.
    name: PowerEdge R7525
    serial: 425FY63
    main_memory:
    ram_size: 1099511627776
    memory_devices:
    dimm_a1:
    size: 68719476736
    technology: dram
    dimm_a2:
    size: 68719476736
    technology: dram
    dimm_a3:
    size: 68719476736
    technology: dram
    dimm_a4:
    size: 68719476736
    technology: dram
    dimm_a5:
    size: 68719476736
    technology: dram
    dimm_a6:
    size: 68719476736
    technology: dram
    dimm_a7:
    size: 68719476736
    technology: dram
    dimm_a8:
    size: 68719476736
    technology: dram
    dimm_b1:
    size: 68719476736
    technology: dram
    dimm_b2:
    size: 68719476736
    technology: dram
    dimm_b3:
    size: 68719476736
    technology: dram
    dimm_b4:
    size: 68719476736
    technology: dram
    dimm_b5:
    size: 68719476736
    technology: dram
    dimm_b6:
    size: 68719476736
    technology: dram
    dimm_b7:
    size: 68719476736
    technology: dram
    dimm_b8:
    size: 68719476736
    technology: dram
    network_adapters:
    bmc:
    ip: 172.17.130.46
    mac: 70:b5:e8:d7:6a:4a
    management: true
    eth0:
    driver: tg3
    firmware_version: FFV23.11.4 bc 5720-v1.39
    interface: Ethernet
    ip: 172.16.130.46
    mac: f4:02:70:b9:2b:b6
    management: false
    model: NetXtreme BCM5720 2-port Gigabit Ethernet PCIe
    name: eno1
    rate: 1000000000
    sriov: false
    sriov_totalvfs: 0
    vendor: Broadcom Inc. and subsidiaries
    eth1:
    driver: tg3
    firmware_version: FFV23.11.4 bc 5720-v1.39
    interface: Ethernet
    mac: f4:02:70:b9:2b:b7
    management: false
    model: NetXtreme BCM5720 2-port Gigabit Ethernet PCIe
    name: eno2
    sriov: false
    sriov_totalvfs: 0
    vendor: Broadcom Inc. and subsidiaries
    ib0:
    driver: mlx4_core
    firmware_version: 2.42.5000
    guid: '0x043f72030017fd91'
    interface: InfiniBand
    ip: 172.18.130.46
    mac: 04:3f:72:03:00:17:fd:91
    management: false
    model: MT27520 Family [ConnectX-3 Pro]
    name: ib0
    rate: 40000000000
    vendor: Mellanox Technologies
    operating_system:
    cstate_driver: acpi_idle
    cstate_governor: menu
    ht_enabled: true
    pstate_driver: acpi-cpufreq
    pstate_governor: performance
    turboboost_enabled: true
    processor:
    cache_l1d: 32768
    cache_l1i: 32768
    cache_l2: 524288
    cache_l3: 16777216
    ht_capable: true
    instruction_set: x86-64
    microcode: '0x830107d'
    model: AMD EPYC
    other_description: AMD EPYC 7542 32-Core Processor
    vendor: AMD
    version: 7542
    storage_devices:
    pci-0000:01:00.0-scsi-0:2:0:0:
    by_id: "/dev/disk/by-id/wwn-0x670b5e80d622090027c144d0ef5cacdf"
    by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0"
    firmware_version: 5.16
    model: PERC H745 Frnt
    size: 239444426752
    storage: SSD
    pci-0000:01:00.0-scsi-0:2:1:0:
    by_id: "/dev/disk/by-id/wwn-0x670b5e80d622090027c149ae2f2d9cb4"
    by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:1:0"
    firmware_version: 5.16
    model: PERC H745 Frnt
    size: 1918239768576
    storage: SSD
    supported_job_types:
    virtual: amd-v
    ...@@ -224,6 +224,11 @@ kinovis: ...@@ -224,6 +224,11 @@ kinovis:
    mercantour2: mercantour2:
    enp1s0f0np0: eth0 enp1s0f0np0: eth0
    eno2: eth1 eno2: eth1
    mercantour6:
    enp1s0f0np0: eth0
    eno1: eth0
    eno2: eth1
    ibp65s0: ib0
    montcalm: montcalm:
    ens10f0np0: eth0 ens10f0np0: eth0
    ens10f1np1: eth1 ens10f1np1: eth1
    ......
    0% Loading or .
    You are about to add 0 people to the discussion. Proceed with caution.
    Please register or to comment