From 10b6680d416d7c543f705f64db12a94047ca6545 Mon Sep 17 00:00:00 2001 From: Pierre Jacquot <pierre.jacquot@inria.fr> Date: Tue, 8 Oct 2024 17:48:58 +0200 Subject: [PATCH] [nantes][ecotype] Redeclare eth1 rate since ecotype-prod2 is back online This reverts commit 471ed002b107909b255d12b203162c00929a34ec. --- data/grid5000/accesses/refrepo.json | 576 +++++++++++++----- .../nantes/clusters/ecotype/ecotype.json | 88 +++ .../clusters/ecotype/nodes/ecotype-1.json | 51 +- .../clusters/ecotype/nodes/ecotype-10.json | 52 +- .../clusters/ecotype/nodes/ecotype-11.json | 52 +- .../clusters/ecotype/nodes/ecotype-12.json | 52 +- .../clusters/ecotype/nodes/ecotype-13.json | 52 +- .../clusters/ecotype/nodes/ecotype-14.json | 52 +- .../clusters/ecotype/nodes/ecotype-15.json | 52 +- .../clusters/ecotype/nodes/ecotype-16.json | 52 +- .../clusters/ecotype/nodes/ecotype-17.json | 52 +- .../clusters/ecotype/nodes/ecotype-18.json | 52 +- .../clusters/ecotype/nodes/ecotype-19.json | 52 +- .../clusters/ecotype/nodes/ecotype-2.json | 52 +- .../clusters/ecotype/nodes/ecotype-20.json | 52 +- .../clusters/ecotype/nodes/ecotype-21.json | 52 +- .../clusters/ecotype/nodes/ecotype-22.json | 52 +- .../clusters/ecotype/nodes/ecotype-23.json | 52 +- .../clusters/ecotype/nodes/ecotype-24.json | 52 +- .../clusters/ecotype/nodes/ecotype-25.json | 52 +- .../clusters/ecotype/nodes/ecotype-26.json | 52 +- .../clusters/ecotype/nodes/ecotype-27.json | 52 +- .../clusters/ecotype/nodes/ecotype-28.json | 52 +- .../clusters/ecotype/nodes/ecotype-29.json | 52 +- .../clusters/ecotype/nodes/ecotype-3.json | 52 +- .../clusters/ecotype/nodes/ecotype-30.json | 52 +- .../clusters/ecotype/nodes/ecotype-31.json | 52 +- .../clusters/ecotype/nodes/ecotype-32.json | 52 +- .../clusters/ecotype/nodes/ecotype-33.json | 52 +- .../clusters/ecotype/nodes/ecotype-34.json | 52 +- .../clusters/ecotype/nodes/ecotype-35.json | 52 +- .../clusters/ecotype/nodes/ecotype-36.json | 52 +- .../clusters/ecotype/nodes/ecotype-37.json | 52 +- .../clusters/ecotype/nodes/ecotype-38.json | 52 +- .../clusters/ecotype/nodes/ecotype-39.json | 52 +- .../clusters/ecotype/nodes/ecotype-4.json | 52 +- .../clusters/ecotype/nodes/ecotype-40.json | 52 +- .../clusters/ecotype/nodes/ecotype-41.json | 52 +- .../clusters/ecotype/nodes/ecotype-42.json | 52 +- .../clusters/ecotype/nodes/ecotype-43.json | 52 +- .../clusters/ecotype/nodes/ecotype-44.json | 52 +- .../clusters/ecotype/nodes/ecotype-45.json | 52 +- .../clusters/ecotype/nodes/ecotype-46.json | 52 +- .../clusters/ecotype/nodes/ecotype-47.json | 53 +- .../clusters/ecotype/nodes/ecotype-48.json | 52 +- .../clusters/ecotype/nodes/ecotype-5.json | 52 +- .../clusters/ecotype/nodes/ecotype-6.json | 52 +- .../clusters/ecotype/nodes/ecotype-7.json | 52 +- .../clusters/ecotype/nodes/ecotype-8.json | 52 +- .../clusters/ecotype/nodes/ecotype-9.json | 52 +- .../network_equipments/ecotype-prod2.json | 192 ++++++ .../nantes/clusters/ecotype/ecotype.yaml | 4 +- .../clusters/ecotype/nodes/ecotype-10.yaml | 1 + .../clusters/ecotype/nodes/ecotype-11.yaml | 1 + .../clusters/ecotype/nodes/ecotype-12.yaml | 1 + .../clusters/ecotype/nodes/ecotype-13.yaml | 1 + .../clusters/ecotype/nodes/ecotype-14.yaml | 1 + .../clusters/ecotype/nodes/ecotype-15.yaml | 1 + .../clusters/ecotype/nodes/ecotype-16.yaml | 1 + .../clusters/ecotype/nodes/ecotype-17.yaml | 1 + .../clusters/ecotype/nodes/ecotype-18.yaml | 1 + .../clusters/ecotype/nodes/ecotype-19.yaml | 1 + .../clusters/ecotype/nodes/ecotype-2.yaml | 1 + .../clusters/ecotype/nodes/ecotype-20.yaml | 1 + .../clusters/ecotype/nodes/ecotype-21.yaml | 1 + .../clusters/ecotype/nodes/ecotype-22.yaml | 1 + .../clusters/ecotype/nodes/ecotype-23.yaml | 1 + .../clusters/ecotype/nodes/ecotype-24.yaml | 1 + .../clusters/ecotype/nodes/ecotype-25.yaml | 1 + .../clusters/ecotype/nodes/ecotype-26.yaml | 1 + .../clusters/ecotype/nodes/ecotype-27.yaml | 1 + .../clusters/ecotype/nodes/ecotype-28.yaml | 1 + .../clusters/ecotype/nodes/ecotype-29.yaml | 1 + .../clusters/ecotype/nodes/ecotype-3.yaml | 1 + .../clusters/ecotype/nodes/ecotype-30.yaml | 1 + .../clusters/ecotype/nodes/ecotype-31.yaml | 1 + .../clusters/ecotype/nodes/ecotype-32.yaml | 1 + .../clusters/ecotype/nodes/ecotype-33.yaml | 1 + .../clusters/ecotype/nodes/ecotype-34.yaml | 1 + .../clusters/ecotype/nodes/ecotype-35.yaml | 1 + .../clusters/ecotype/nodes/ecotype-36.yaml | 1 + .../clusters/ecotype/nodes/ecotype-37.yaml | 1 + .../clusters/ecotype/nodes/ecotype-38.yaml | 1 + .../clusters/ecotype/nodes/ecotype-39.yaml | 1 + .../clusters/ecotype/nodes/ecotype-4.yaml | 1 + .../clusters/ecotype/nodes/ecotype-40.yaml | 1 + .../clusters/ecotype/nodes/ecotype-41.yaml | 1 + .../clusters/ecotype/nodes/ecotype-42.yaml | 1 + .../clusters/ecotype/nodes/ecotype-43.yaml | 1 + .../clusters/ecotype/nodes/ecotype-44.yaml | 1 + .../clusters/ecotype/nodes/ecotype-45.yaml | 1 + .../clusters/ecotype/nodes/ecotype-46.yaml | 1 + .../clusters/ecotype/nodes/ecotype-47.yaml | 2 +- .../clusters/ecotype/nodes/ecotype-48.yaml | 1 + .../clusters/ecotype/nodes/ecotype-5.yaml | 1 + .../clusters/ecotype/nodes/ecotype-6.yaml | 1 + .../clusters/ecotype/nodes/ecotype-7.yaml | 1 + .../clusters/ecotype/nodes/ecotype-8.yaml | 1 + .../clusters/ecotype/nodes/ecotype-9.yaml | 1 + .../sites/nantes/networks/ecotype-prod2.yaml | 96 +-- lib/refrepo/valid/data/homogeneity.yaml.erb | 6 + 101 files changed, 3165 insertions(+), 341 deletions(-) diff --git a/data/grid5000/accesses/refrepo.json b/data/grid5000/accesses/refrepo.json index 0b3b588d7f5..f4d6bec7889 100644 --- a/data/grid5000/accesses/refrepo.json +++ b/data/grid5000/accesses/refrepo.json @@ -87119,18 +87119,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.1", + "ip6": "2001:660:4406:600:2:1:0:1", + "kavlan": true, "mac": "24:6e:96:6a:46:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-1-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/1", "vendor": "Intel" }, { @@ -87294,18 +87299,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.10", + "ip6": "2001:660:4406:600:2:1:0:a", + "kavlan": true, "mac": "24:6e:96:6a:d1:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-10-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/10", "vendor": "Intel" }, { @@ -87469,18 +87480,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.11", + "ip6": "2001:660:4406:600:2:1:0:b", + "kavlan": true, "mac": "24:6e:96:6a:4f:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-11-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/11", "vendor": "Intel" }, { @@ -87644,18 +87661,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.12", + "ip6": "2001:660:4406:600:2:1:0:c", + "kavlan": true, "mac": "24:6e:96:6a:52:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-12-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/12", "vendor": "Intel" }, { @@ -87819,18 +87842,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.13", + "ip6": "2001:660:4406:600:2:1:0:d", + "kavlan": true, "mac": "24:6e:96:6a:49:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-13-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/13", "vendor": "Intel" }, { @@ -87994,18 +88023,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.14", + "ip6": "2001:660:4406:600:2:1:0:e", + "kavlan": true, "mac": "24:6e:96:6a:46:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-14-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/14", "vendor": "Intel" }, { @@ -88169,18 +88204,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.15", + "ip6": "2001:660:4406:600:2:1:0:f", + "kavlan": true, "mac": "24:6e:96:6a:46:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-15-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/15", "vendor": "Intel" }, { @@ -88344,18 +88385,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.16", + "ip6": "2001:660:4406:600:2:1:0:10", + "kavlan": true, "mac": "24:6e:96:6a:46:c2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-16-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/16", "vendor": "Intel" }, { @@ -88519,18 +88566,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.17", + "ip6": "2001:660:4406:600:2:1:0:11", + "kavlan": true, "mac": "24:6e:96:6a:47:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-17-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/17", "vendor": "Intel" }, { @@ -88694,18 +88747,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.18", + "ip6": "2001:660:4406:600:2:1:0:12", + "kavlan": true, "mac": "24:6e:96:6a:5a:5a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-18-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/18", "vendor": "Intel" }, { @@ -88869,18 +88928,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.19", + "ip6": "2001:660:4406:600:2:1:0:13", + "kavlan": true, "mac": "24:6e:96:6a:59:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-19-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/19", "vendor": "Intel" }, { @@ -89044,18 +89109,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.2", + "ip6": "2001:660:4406:600:2:1:0:2", + "kavlan": true, "mac": "24:6e:96:6a:d0:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-2-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/2", "vendor": "Intel" }, { @@ -89219,18 +89290,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.20", + "ip6": "2001:660:4406:600:2:1:0:14", + "kavlan": true, "mac": "24:6e:96:6a:50:12", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-20-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/20", "vendor": "Intel" }, { @@ -89394,18 +89471,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.21", + "ip6": "2001:660:4406:600:2:1:0:15", + "kavlan": true, "mac": "24:6e:96:6a:c9:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-21-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/21", "vendor": "Intel" }, { @@ -89569,18 +89652,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.22", + "ip6": "2001:660:4406:600:2:1:0:16", + "kavlan": true, "mac": "24:6e:96:6a:d3:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-22-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/22", "vendor": "Intel" }, { @@ -89744,18 +89833,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.23", + "ip6": "2001:660:4406:600:2:1:0:17", + "kavlan": true, "mac": "24:6e:96:6a:4e:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-23-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/23", "vendor": "Intel" }, { @@ -89919,18 +90014,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.24", + "ip6": "2001:660:4406:600:2:1:0:18", + "kavlan": true, "mac": "24:6e:96:6a:cf:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-24-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/24", "vendor": "Intel" }, { @@ -90094,18 +90195,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.25", + "ip6": "2001:660:4406:600:2:1:0:19", + "kavlan": true, "mac": "24:6e:96:6a:48:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-25-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/25", "vendor": "Intel" }, { @@ -90269,18 +90376,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.26", + "ip6": "2001:660:4406:600:2:1:0:1a", + "kavlan": true, "mac": "24:6e:96:6a:4e:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-26-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/26", "vendor": "Intel" }, { @@ -90444,18 +90557,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.27", + "ip6": "2001:660:4406:600:2:1:0:1b", + "kavlan": true, "mac": "24:6e:96:6a:d9:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-27-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/27", "vendor": "Intel" }, { @@ -90619,18 +90738,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.28", + "ip6": "2001:660:4406:600:2:1:0:1c", + "kavlan": true, "mac": "24:6e:96:6a:ca:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-28-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/28", "vendor": "Intel" }, { @@ -90794,18 +90919,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.29", + "ip6": "2001:660:4406:600:2:1:0:1d", + "kavlan": true, "mac": "24:6e:96:6a:d8:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-29-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/29", "vendor": "Intel" }, { @@ -90969,18 +91100,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.3", + "ip6": "2001:660:4406:600:2:1:0:3", + "kavlan": true, "mac": "24:6e:96:6a:d7:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-3-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/3", "vendor": "Intel" }, { @@ -91144,18 +91281,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.30", + "ip6": "2001:660:4406:600:2:1:0:1e", + "kavlan": true, "mac": "24:6e:96:6a:51:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-30-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/30", "vendor": "Intel" }, { @@ -91319,18 +91462,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.31", + "ip6": "2001:660:4406:600:2:1:0:1f", + "kavlan": true, "mac": "24:6e:96:6a:d8:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-31-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/31", "vendor": "Intel" }, { @@ -91494,18 +91643,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.32", + "ip6": "2001:660:4406:600:2:1:0:20", + "kavlan": true, "mac": "24:6e:96:6a:d6:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-32-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/32", "vendor": "Intel" }, { @@ -91669,18 +91824,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.33", + "ip6": "2001:660:4406:600:2:1:0:21", + "kavlan": true, "mac": "24:6e:96:6a:4e:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-33-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/33", "vendor": "Intel" }, { @@ -91844,18 +92005,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.34", + "ip6": "2001:660:4406:600:2:1:0:22", + "kavlan": true, "mac": "24:6e:96:6a:c9:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-34-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/34", "vendor": "Intel" }, { @@ -92019,18 +92186,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.35", + "ip6": "2001:660:4406:600:2:1:0:23", + "kavlan": true, "mac": "24:6e:96:6a:d1:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-35-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/35", "vendor": "Intel" }, { @@ -92194,18 +92367,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.36", + "ip6": "2001:660:4406:600:2:1:0:24", + "kavlan": true, "mac": "24:6e:96:6a:56:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-36-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/36", "vendor": "Intel" }, { @@ -92369,18 +92548,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.37", + "ip6": "2001:660:4406:600:2:1:0:25", + "kavlan": true, "mac": "24:6e:96:6a:cc:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-37-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/37", "vendor": "Intel" }, { @@ -92544,18 +92729,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.38", + "ip6": "2001:660:4406:600:2:1:0:26", + "kavlan": true, "mac": "24:6e:96:6a:d7:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-38-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/38", "vendor": "Intel" }, { @@ -92719,18 +92910,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.39", + "ip6": "2001:660:4406:600:2:1:0:27", + "kavlan": true, "mac": "24:6e:96:6a:d1:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-39-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/39", "vendor": "Intel" }, { @@ -92894,18 +93091,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.4", + "ip6": "2001:660:4406:600:2:1:0:4", + "kavlan": true, "mac": "24:6e:96:6a:d7:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-4-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/4", "vendor": "Intel" }, { @@ -93069,18 +93272,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.40", + "ip6": "2001:660:4406:600:2:1:0:28", + "kavlan": true, "mac": "24:6e:96:6a:4f:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-40-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/40", "vendor": "Intel" }, { @@ -93244,18 +93453,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.41", + "ip6": "2001:660:4406:600:2:1:0:29", + "kavlan": true, "mac": "24:6e:96:6a:49:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-41-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/41", "vendor": "Intel" }, { @@ -93419,18 +93634,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.42", + "ip6": "2001:660:4406:600:2:1:0:2a", + "kavlan": true, "mac": "24:6e:96:6a:4c:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-42-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/42", "vendor": "Intel" }, { @@ -93594,18 +93815,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.43", + "ip6": "2001:660:4406:600:2:1:0:2b", + "kavlan": true, "mac": "24:6e:96:6a:d0:82", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-43-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/43", "vendor": "Intel" }, { @@ -93769,18 +93996,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.44", + "ip6": "2001:660:4406:600:2:1:0:2c", + "kavlan": true, "mac": "24:6e:96:6a:63:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-44-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/44", "vendor": "Intel" }, { @@ -93944,18 +94177,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.45", + "ip6": "2001:660:4406:600:2:1:0:2d", + "kavlan": true, "mac": "24:6e:96:6a:47:42", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-45-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/45", "vendor": "Intel" }, { @@ -94119,18 +94358,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.46", + "ip6": "2001:660:4406:600:2:1:0:2e", + "kavlan": true, "mac": "24:6e:96:6a:c9:aa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-46-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/46", "vendor": "Intel" }, { @@ -94294,18 +94539,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.47", + "ip6": "2001:660:4406:600:2:1:0:2f", + "kavlan": true, "mac": "24:6e:96:6a:d1:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-47-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/47", "vendor": "Intel" }, { @@ -94346,7 +94596,7 @@ "device": "bmc", "enabled": true, "interface": "Ethernet", - "ip": "172.17.193.47", + "ip": "0.0.0.0", "kavlan": false, "mac": "50:9a:4c:a8:8d:9c", "management": true, @@ -94469,18 +94719,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.48", + "ip6": "2001:660:4406:600:2:1:0:30", + "kavlan": true, "mac": "24:6e:96:6a:cf:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-48-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/48", "vendor": "Intel" }, { @@ -94644,18 +94900,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.5", + "ip6": "2001:660:4406:600:2:1:0:5", + "kavlan": true, "mac": "24:6e:96:6a:d3:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-5-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/5", "vendor": "Intel" }, { @@ -94819,18 +95081,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.6", + "ip6": "2001:660:4406:600:2:1:0:6", + "kavlan": true, "mac": "24:6e:96:6a:d6:b2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-6-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/6", "vendor": "Intel" }, { @@ -94994,18 +95262,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.7", + "ip6": "2001:660:4406:600:2:1:0:7", + "kavlan": true, "mac": "24:6e:96:6a:4f:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-7-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/7", "vendor": "Intel" }, { @@ -95169,18 +95443,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.8", + "ip6": "2001:660:4406:600:2:1:0:8", + "kavlan": true, "mac": "24:6e:96:6a:c9:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-8-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/8", "vendor": "Intel" }, { @@ -95344,18 +95624,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.9", + "ip6": "2001:660:4406:600:2:1:0:9", + "kavlan": true, "mac": "24:6e:96:6a:d7:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-9-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/9", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json b/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json index 1fd2951a825..b85893bee71 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json @@ -441,6 +441,94 @@ "source": { "protocol": "network_equipment" } + }, + { + "description": "Input byte counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_bytes_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output byte counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_bytes_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input packet counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output packet counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of discarded packets for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_discard_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of discarded packets for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_discard_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of packet errors for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_error_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of packet errors for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_error_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } } ], "model": "Dell PowerEdge R630", diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json index ce0e85fe3fc..9a80223e73d 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.1", "kavlan-8": "10.45.1.1", "kavlan-9": "10.45.65.1" + }, + "eth1": { + "kavlan-1": "192.168.194.1", + "kavlan-11": "10.7.241.101", + "kavlan-12": "10.11.241.101", + "kavlan-13": "10.15.241.101", + "kavlan-14": "10.19.241.101", + "kavlan-16": "10.27.241.101", + "kavlan-17": "10.31.241.101", + "kavlan-18": "10.35.241.101", + "kavlan-2": "192.168.210.1", + "kavlan-20": "10.43.241.101", + "kavlan-21": "10.47.241.101", + "kavlan-3": "192.168.226.1", + "kavlan-4": "10.44.2.1", + "kavlan-5": "10.44.66.1", + "kavlan-6": "10.44.130.1", + "kavlan-7": "10.44.194.1", + "kavlan-8": "10.45.2.1", + "kavlan-9": "10.45.66.1" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1", "kavlan-8": "2001:660:4406:694:2::1", "kavlan-9": "2001:660:4406:695:2::1" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1", + "kavlan-2": "2001:660:4406:681:2:1:0:1", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1", + "kavlan-3": "2001:660:4406:682:2:1:0:1", + "kavlan-4": "2001:660:4406:690:2:1:0:1", + "kavlan-5": "2001:660:4406:691:2:1:0:1", + "kavlan-6": "2001:660:4406:692:2:1:0:1", + "kavlan-7": "2001:660:4406:693:2:1:0:1", + "kavlan-8": "2001:660:4406:694:2:1:0:1", + "kavlan-9": "2001:660:4406:695:2:1:0:1" } }, "main_memory": { @@ -142,18 +182,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.1", + "ip6": "2001:660:4406:600:2:1:0:1", + "kavlan": true, "mac": "24:6e:96:6a:46:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-1-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/1", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json index a0efbe0dea6..21ac75fb54a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.10", "kavlan-8": "10.45.1.10", "kavlan-9": "10.45.65.10" + }, + "eth1": { + "kavlan-1": "192.168.194.10", + "kavlan-11": "10.7.241.110", + "kavlan-12": "10.11.241.110", + "kavlan-13": "10.15.241.110", + "kavlan-14": "10.19.241.110", + "kavlan-16": "10.27.241.110", + "kavlan-17": "10.31.241.110", + "kavlan-18": "10.35.241.110", + "kavlan-2": "192.168.210.10", + "kavlan-20": "10.43.241.110", + "kavlan-21": "10.47.241.110", + "kavlan-3": "192.168.226.10", + "kavlan-4": "10.44.2.10", + "kavlan-5": "10.44.66.10", + "kavlan-6": "10.44.130.10", + "kavlan-7": "10.44.194.10", + "kavlan-8": "10.45.2.10", + "kavlan-9": "10.45.66.10" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::a", "kavlan-8": "2001:660:4406:694:2::a", "kavlan-9": "2001:660:4406:695:2::a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:a", + "kavlan-2": "2001:660:4406:681:2:1:0:a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:a", + "kavlan-3": "2001:660:4406:682:2:1:0:a", + "kavlan-4": "2001:660:4406:690:2:1:0:a", + "kavlan-5": "2001:660:4406:691:2:1:0:a", + "kavlan-6": "2001:660:4406:692:2:1:0:a", + "kavlan-7": "2001:660:4406:693:2:1:0:a", + "kavlan-8": "2001:660:4406:694:2:1:0:a", + "kavlan-9": "2001:660:4406:695:2:1:0:a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.10", + "ip6": "2001:660:4406:600:2:1:0:a", + "kavlan": true, "mac": "24:6e:96:6a:d1:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-10-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/10", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json index 114b0466f2a..3c48b2482a4 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.11", "kavlan-8": "10.45.1.11", "kavlan-9": "10.45.65.11" + }, + "eth1": { + "kavlan-1": "192.168.194.11", + "kavlan-11": "10.7.241.111", + "kavlan-12": "10.11.241.111", + "kavlan-13": "10.15.241.111", + "kavlan-14": "10.19.241.111", + "kavlan-16": "10.27.241.111", + "kavlan-17": "10.31.241.111", + "kavlan-18": "10.35.241.111", + "kavlan-2": "192.168.210.11", + "kavlan-20": "10.43.241.111", + "kavlan-21": "10.47.241.111", + "kavlan-3": "192.168.226.11", + "kavlan-4": "10.44.2.11", + "kavlan-5": "10.44.66.11", + "kavlan-6": "10.44.130.11", + "kavlan-7": "10.44.194.11", + "kavlan-8": "10.45.2.11", + "kavlan-9": "10.45.66.11" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::b", "kavlan-8": "2001:660:4406:694:2::b", "kavlan-9": "2001:660:4406:695:2::b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:b", + "kavlan-2": "2001:660:4406:681:2:1:0:b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:b", + "kavlan-3": "2001:660:4406:682:2:1:0:b", + "kavlan-4": "2001:660:4406:690:2:1:0:b", + "kavlan-5": "2001:660:4406:691:2:1:0:b", + "kavlan-6": "2001:660:4406:692:2:1:0:b", + "kavlan-7": "2001:660:4406:693:2:1:0:b", + "kavlan-8": "2001:660:4406:694:2:1:0:b", + "kavlan-9": "2001:660:4406:695:2:1:0:b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.11", + "ip6": "2001:660:4406:600:2:1:0:b", + "kavlan": true, "mac": "24:6e:96:6a:4f:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-11-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/11", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json index 446618e9c09..5e650a0ea82 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.12", "kavlan-8": "10.45.1.12", "kavlan-9": "10.45.65.12" + }, + "eth1": { + "kavlan-1": "192.168.194.12", + "kavlan-11": "10.7.241.112", + "kavlan-12": "10.11.241.112", + "kavlan-13": "10.15.241.112", + "kavlan-14": "10.19.241.112", + "kavlan-16": "10.27.241.112", + "kavlan-17": "10.31.241.112", + "kavlan-18": "10.35.241.112", + "kavlan-2": "192.168.210.12", + "kavlan-20": "10.43.241.112", + "kavlan-21": "10.47.241.112", + "kavlan-3": "192.168.226.12", + "kavlan-4": "10.44.2.12", + "kavlan-5": "10.44.66.12", + "kavlan-6": "10.44.130.12", + "kavlan-7": "10.44.194.12", + "kavlan-8": "10.45.2.12", + "kavlan-9": "10.45.66.12" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::c", "kavlan-8": "2001:660:4406:694:2::c", "kavlan-9": "2001:660:4406:695:2::c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:c", + "kavlan-2": "2001:660:4406:681:2:1:0:c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:c", + "kavlan-3": "2001:660:4406:682:2:1:0:c", + "kavlan-4": "2001:660:4406:690:2:1:0:c", + "kavlan-5": "2001:660:4406:691:2:1:0:c", + "kavlan-6": "2001:660:4406:692:2:1:0:c", + "kavlan-7": "2001:660:4406:693:2:1:0:c", + "kavlan-8": "2001:660:4406:694:2:1:0:c", + "kavlan-9": "2001:660:4406:695:2:1:0:c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.12", + "ip6": "2001:660:4406:600:2:1:0:c", + "kavlan": true, "mac": "24:6e:96:6a:52:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-12-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/12", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json index 2703c63b750..5516346fb0c 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.13", "kavlan-8": "10.45.1.13", "kavlan-9": "10.45.65.13" + }, + "eth1": { + "kavlan-1": "192.168.194.13", + "kavlan-11": "10.7.241.113", + "kavlan-12": "10.11.241.113", + "kavlan-13": "10.15.241.113", + "kavlan-14": "10.19.241.113", + "kavlan-16": "10.27.241.113", + "kavlan-17": "10.31.241.113", + "kavlan-18": "10.35.241.113", + "kavlan-2": "192.168.210.13", + "kavlan-20": "10.43.241.113", + "kavlan-21": "10.47.241.113", + "kavlan-3": "192.168.226.13", + "kavlan-4": "10.44.2.13", + "kavlan-5": "10.44.66.13", + "kavlan-6": "10.44.130.13", + "kavlan-7": "10.44.194.13", + "kavlan-8": "10.45.2.13", + "kavlan-9": "10.45.66.13" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::d", "kavlan-8": "2001:660:4406:694:2::d", "kavlan-9": "2001:660:4406:695:2::d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:d", + "kavlan-2": "2001:660:4406:681:2:1:0:d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:d", + "kavlan-3": "2001:660:4406:682:2:1:0:d", + "kavlan-4": "2001:660:4406:690:2:1:0:d", + "kavlan-5": "2001:660:4406:691:2:1:0:d", + "kavlan-6": "2001:660:4406:692:2:1:0:d", + "kavlan-7": "2001:660:4406:693:2:1:0:d", + "kavlan-8": "2001:660:4406:694:2:1:0:d", + "kavlan-9": "2001:660:4406:695:2:1:0:d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.13", + "ip6": "2001:660:4406:600:2:1:0:d", + "kavlan": true, "mac": "24:6e:96:6a:49:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-13-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/13", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json index 9103883acf6..a813e287ce2 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.14", "kavlan-8": "10.45.1.14", "kavlan-9": "10.45.65.14" + }, + "eth1": { + "kavlan-1": "192.168.194.14", + "kavlan-11": "10.7.241.114", + "kavlan-12": "10.11.241.114", + "kavlan-13": "10.15.241.114", + "kavlan-14": "10.19.241.114", + "kavlan-16": "10.27.241.114", + "kavlan-17": "10.31.241.114", + "kavlan-18": "10.35.241.114", + "kavlan-2": "192.168.210.14", + "kavlan-20": "10.43.241.114", + "kavlan-21": "10.47.241.114", + "kavlan-3": "192.168.226.14", + "kavlan-4": "10.44.2.14", + "kavlan-5": "10.44.66.14", + "kavlan-6": "10.44.130.14", + "kavlan-7": "10.44.194.14", + "kavlan-8": "10.45.2.14", + "kavlan-9": "10.45.66.14" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::e", "kavlan-8": "2001:660:4406:694:2::e", "kavlan-9": "2001:660:4406:695:2::e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:e", + "kavlan-2": "2001:660:4406:681:2:1:0:e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:e", + "kavlan-3": "2001:660:4406:682:2:1:0:e", + "kavlan-4": "2001:660:4406:690:2:1:0:e", + "kavlan-5": "2001:660:4406:691:2:1:0:e", + "kavlan-6": "2001:660:4406:692:2:1:0:e", + "kavlan-7": "2001:660:4406:693:2:1:0:e", + "kavlan-8": "2001:660:4406:694:2:1:0:e", + "kavlan-9": "2001:660:4406:695:2:1:0:e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.14", + "ip6": "2001:660:4406:600:2:1:0:e", + "kavlan": true, "mac": "24:6e:96:6a:46:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-14-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/14", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json index 708c6fe3d95..83f92786469 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.15", "kavlan-8": "10.45.1.15", "kavlan-9": "10.45.65.15" + }, + "eth1": { + "kavlan-1": "192.168.194.15", + "kavlan-11": "10.7.241.115", + "kavlan-12": "10.11.241.115", + "kavlan-13": "10.15.241.115", + "kavlan-14": "10.19.241.115", + "kavlan-16": "10.27.241.115", + "kavlan-17": "10.31.241.115", + "kavlan-18": "10.35.241.115", + "kavlan-2": "192.168.210.15", + "kavlan-20": "10.43.241.115", + "kavlan-21": "10.47.241.115", + "kavlan-3": "192.168.226.15", + "kavlan-4": "10.44.2.15", + "kavlan-5": "10.44.66.15", + "kavlan-6": "10.44.130.15", + "kavlan-7": "10.44.194.15", + "kavlan-8": "10.45.2.15", + "kavlan-9": "10.45.66.15" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::f", "kavlan-8": "2001:660:4406:694:2::f", "kavlan-9": "2001:660:4406:695:2::f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:f", + "kavlan-2": "2001:660:4406:681:2:1:0:f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:f", + "kavlan-3": "2001:660:4406:682:2:1:0:f", + "kavlan-4": "2001:660:4406:690:2:1:0:f", + "kavlan-5": "2001:660:4406:691:2:1:0:f", + "kavlan-6": "2001:660:4406:692:2:1:0:f", + "kavlan-7": "2001:660:4406:693:2:1:0:f", + "kavlan-8": "2001:660:4406:694:2:1:0:f", + "kavlan-9": "2001:660:4406:695:2:1:0:f" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.15", + "ip6": "2001:660:4406:600:2:1:0:f", + "kavlan": true, "mac": "24:6e:96:6a:46:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-15-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/15", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json index 03e8b0251a7..d0b896ff6ac 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.16", "kavlan-8": "10.45.1.16", "kavlan-9": "10.45.65.16" + }, + "eth1": { + "kavlan-1": "192.168.194.16", + "kavlan-11": "10.7.241.116", + "kavlan-12": "10.11.241.116", + "kavlan-13": "10.15.241.116", + "kavlan-14": "10.19.241.116", + "kavlan-16": "10.27.241.116", + "kavlan-17": "10.31.241.116", + "kavlan-18": "10.35.241.116", + "kavlan-2": "192.168.210.16", + "kavlan-20": "10.43.241.116", + "kavlan-21": "10.47.241.116", + "kavlan-3": "192.168.226.16", + "kavlan-4": "10.44.2.16", + "kavlan-5": "10.44.66.16", + "kavlan-6": "10.44.130.16", + "kavlan-7": "10.44.194.16", + "kavlan-8": "10.45.2.16", + "kavlan-9": "10.45.66.16" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::10", "kavlan-8": "2001:660:4406:694:2::10", "kavlan-9": "2001:660:4406:695:2::10" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:10", + "kavlan-11": "2001:660:4406:1a0:602:1:0:10", + "kavlan-12": "2001:660:4406:2a0:602:1:0:10", + "kavlan-13": "2001:660:4406:4a0:602:1:0:10", + "kavlan-14": "2001:660:4406:5a0:602:1:0:10", + "kavlan-16": "2001:660:4406:7a0:602:1:0:10", + "kavlan-17": "2001:660:4406:9a0:602:1:0:10", + "kavlan-18": "2001:660:4406:8a0:602:1:0:10", + "kavlan-2": "2001:660:4406:681:2:1:0:10", + "kavlan-20": "2001:660:4406:3a0:602:1:0:10", + "kavlan-21": "2001:660:4406:6a0:602:1:0:10", + "kavlan-3": "2001:660:4406:682:2:1:0:10", + "kavlan-4": "2001:660:4406:690:2:1:0:10", + "kavlan-5": "2001:660:4406:691:2:1:0:10", + "kavlan-6": "2001:660:4406:692:2:1:0:10", + "kavlan-7": "2001:660:4406:693:2:1:0:10", + "kavlan-8": "2001:660:4406:694:2:1:0:10", + "kavlan-9": "2001:660:4406:695:2:1:0:10" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.16", + "ip6": "2001:660:4406:600:2:1:0:10", + "kavlan": true, "mac": "24:6e:96:6a:46:c2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-16-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/16", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json index bca564dcfae..904b7fd1051 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.17", "kavlan-8": "10.45.1.17", "kavlan-9": "10.45.65.17" + }, + "eth1": { + "kavlan-1": "192.168.194.17", + "kavlan-11": "10.7.241.117", + "kavlan-12": "10.11.241.117", + "kavlan-13": "10.15.241.117", + "kavlan-14": "10.19.241.117", + "kavlan-16": "10.27.241.117", + "kavlan-17": "10.31.241.117", + "kavlan-18": "10.35.241.117", + "kavlan-2": "192.168.210.17", + "kavlan-20": "10.43.241.117", + "kavlan-21": "10.47.241.117", + "kavlan-3": "192.168.226.17", + "kavlan-4": "10.44.2.17", + "kavlan-5": "10.44.66.17", + "kavlan-6": "10.44.130.17", + "kavlan-7": "10.44.194.17", + "kavlan-8": "10.45.2.17", + "kavlan-9": "10.45.66.17" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::11", "kavlan-8": "2001:660:4406:694:2::11", "kavlan-9": "2001:660:4406:695:2::11" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:11", + "kavlan-11": "2001:660:4406:1a0:602:1:0:11", + "kavlan-12": "2001:660:4406:2a0:602:1:0:11", + "kavlan-13": "2001:660:4406:4a0:602:1:0:11", + "kavlan-14": "2001:660:4406:5a0:602:1:0:11", + "kavlan-16": "2001:660:4406:7a0:602:1:0:11", + "kavlan-17": "2001:660:4406:9a0:602:1:0:11", + "kavlan-18": "2001:660:4406:8a0:602:1:0:11", + "kavlan-2": "2001:660:4406:681:2:1:0:11", + "kavlan-20": "2001:660:4406:3a0:602:1:0:11", + "kavlan-21": "2001:660:4406:6a0:602:1:0:11", + "kavlan-3": "2001:660:4406:682:2:1:0:11", + "kavlan-4": "2001:660:4406:690:2:1:0:11", + "kavlan-5": "2001:660:4406:691:2:1:0:11", + "kavlan-6": "2001:660:4406:692:2:1:0:11", + "kavlan-7": "2001:660:4406:693:2:1:0:11", + "kavlan-8": "2001:660:4406:694:2:1:0:11", + "kavlan-9": "2001:660:4406:695:2:1:0:11" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.17", + "ip6": "2001:660:4406:600:2:1:0:11", + "kavlan": true, "mac": "24:6e:96:6a:47:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-17-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/17", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json index 682f4694fb3..27be6723561 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.18", "kavlan-8": "10.45.1.18", "kavlan-9": "10.45.65.18" + }, + "eth1": { + "kavlan-1": "192.168.194.18", + "kavlan-11": "10.7.241.118", + "kavlan-12": "10.11.241.118", + "kavlan-13": "10.15.241.118", + "kavlan-14": "10.19.241.118", + "kavlan-16": "10.27.241.118", + "kavlan-17": "10.31.241.118", + "kavlan-18": "10.35.241.118", + "kavlan-2": "192.168.210.18", + "kavlan-20": "10.43.241.118", + "kavlan-21": "10.47.241.118", + "kavlan-3": "192.168.226.18", + "kavlan-4": "10.44.2.18", + "kavlan-5": "10.44.66.18", + "kavlan-6": "10.44.130.18", + "kavlan-7": "10.44.194.18", + "kavlan-8": "10.45.2.18", + "kavlan-9": "10.45.66.18" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::12", "kavlan-8": "2001:660:4406:694:2::12", "kavlan-9": "2001:660:4406:695:2::12" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:12", + "kavlan-11": "2001:660:4406:1a0:602:1:0:12", + "kavlan-12": "2001:660:4406:2a0:602:1:0:12", + "kavlan-13": "2001:660:4406:4a0:602:1:0:12", + "kavlan-14": "2001:660:4406:5a0:602:1:0:12", + "kavlan-16": "2001:660:4406:7a0:602:1:0:12", + "kavlan-17": "2001:660:4406:9a0:602:1:0:12", + "kavlan-18": "2001:660:4406:8a0:602:1:0:12", + "kavlan-2": "2001:660:4406:681:2:1:0:12", + "kavlan-20": "2001:660:4406:3a0:602:1:0:12", + "kavlan-21": "2001:660:4406:6a0:602:1:0:12", + "kavlan-3": "2001:660:4406:682:2:1:0:12", + "kavlan-4": "2001:660:4406:690:2:1:0:12", + "kavlan-5": "2001:660:4406:691:2:1:0:12", + "kavlan-6": "2001:660:4406:692:2:1:0:12", + "kavlan-7": "2001:660:4406:693:2:1:0:12", + "kavlan-8": "2001:660:4406:694:2:1:0:12", + "kavlan-9": "2001:660:4406:695:2:1:0:12" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.18", + "ip6": "2001:660:4406:600:2:1:0:12", + "kavlan": true, "mac": "24:6e:96:6a:5a:5a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-18-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/18", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json index 490dfd3a527..5999f9dd96a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.19", "kavlan-8": "10.45.1.19", "kavlan-9": "10.45.65.19" + }, + "eth1": { + "kavlan-1": "192.168.194.19", + "kavlan-11": "10.7.241.119", + "kavlan-12": "10.11.241.119", + "kavlan-13": "10.15.241.119", + "kavlan-14": "10.19.241.119", + "kavlan-16": "10.27.241.119", + "kavlan-17": "10.31.241.119", + "kavlan-18": "10.35.241.119", + "kavlan-2": "192.168.210.19", + "kavlan-20": "10.43.241.119", + "kavlan-21": "10.47.241.119", + "kavlan-3": "192.168.226.19", + "kavlan-4": "10.44.2.19", + "kavlan-5": "10.44.66.19", + "kavlan-6": "10.44.130.19", + "kavlan-7": "10.44.194.19", + "kavlan-8": "10.45.2.19", + "kavlan-9": "10.45.66.19" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::13", "kavlan-8": "2001:660:4406:694:2::13", "kavlan-9": "2001:660:4406:695:2::13" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:13", + "kavlan-11": "2001:660:4406:1a0:602:1:0:13", + "kavlan-12": "2001:660:4406:2a0:602:1:0:13", + "kavlan-13": "2001:660:4406:4a0:602:1:0:13", + "kavlan-14": "2001:660:4406:5a0:602:1:0:13", + "kavlan-16": "2001:660:4406:7a0:602:1:0:13", + "kavlan-17": "2001:660:4406:9a0:602:1:0:13", + "kavlan-18": "2001:660:4406:8a0:602:1:0:13", + "kavlan-2": "2001:660:4406:681:2:1:0:13", + "kavlan-20": "2001:660:4406:3a0:602:1:0:13", + "kavlan-21": "2001:660:4406:6a0:602:1:0:13", + "kavlan-3": "2001:660:4406:682:2:1:0:13", + "kavlan-4": "2001:660:4406:690:2:1:0:13", + "kavlan-5": "2001:660:4406:691:2:1:0:13", + "kavlan-6": "2001:660:4406:692:2:1:0:13", + "kavlan-7": "2001:660:4406:693:2:1:0:13", + "kavlan-8": "2001:660:4406:694:2:1:0:13", + "kavlan-9": "2001:660:4406:695:2:1:0:13" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.19", + "ip6": "2001:660:4406:600:2:1:0:13", + "kavlan": true, "mac": "24:6e:96:6a:59:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-19-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/19", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json index 7c394e7babc..14ff080d3ea 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.2", "kavlan-8": "10.45.1.2", "kavlan-9": "10.45.65.2" + }, + "eth1": { + "kavlan-1": "192.168.194.2", + "kavlan-11": "10.7.241.102", + "kavlan-12": "10.11.241.102", + "kavlan-13": "10.15.241.102", + "kavlan-14": "10.19.241.102", + "kavlan-16": "10.27.241.102", + "kavlan-17": "10.31.241.102", + "kavlan-18": "10.35.241.102", + "kavlan-2": "192.168.210.2", + "kavlan-20": "10.43.241.102", + "kavlan-21": "10.47.241.102", + "kavlan-3": "192.168.226.2", + "kavlan-4": "10.44.2.2", + "kavlan-5": "10.44.66.2", + "kavlan-6": "10.44.130.2", + "kavlan-7": "10.44.194.2", + "kavlan-8": "10.45.2.2", + "kavlan-9": "10.45.66.2" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2", "kavlan-8": "2001:660:4406:694:2::2", "kavlan-9": "2001:660:4406:695:2::2" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2", + "kavlan-2": "2001:660:4406:681:2:1:0:2", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2", + "kavlan-3": "2001:660:4406:682:2:1:0:2", + "kavlan-4": "2001:660:4406:690:2:1:0:2", + "kavlan-5": "2001:660:4406:691:2:1:0:2", + "kavlan-6": "2001:660:4406:692:2:1:0:2", + "kavlan-7": "2001:660:4406:693:2:1:0:2", + "kavlan-8": "2001:660:4406:694:2:1:0:2", + "kavlan-9": "2001:660:4406:695:2:1:0:2" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.2", + "ip6": "2001:660:4406:600:2:1:0:2", + "kavlan": true, "mac": "24:6e:96:6a:d0:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-2-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/2", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json index b85d0e64a0b..cbf5d16bdab 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.20", "kavlan-8": "10.45.1.20", "kavlan-9": "10.45.65.20" + }, + "eth1": { + "kavlan-1": "192.168.194.20", + "kavlan-11": "10.7.241.120", + "kavlan-12": "10.11.241.120", + "kavlan-13": "10.15.241.120", + "kavlan-14": "10.19.241.120", + "kavlan-16": "10.27.241.120", + "kavlan-17": "10.31.241.120", + "kavlan-18": "10.35.241.120", + "kavlan-2": "192.168.210.20", + "kavlan-20": "10.43.241.120", + "kavlan-21": "10.47.241.120", + "kavlan-3": "192.168.226.20", + "kavlan-4": "10.44.2.20", + "kavlan-5": "10.44.66.20", + "kavlan-6": "10.44.130.20", + "kavlan-7": "10.44.194.20", + "kavlan-8": "10.45.2.20", + "kavlan-9": "10.45.66.20" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::14", "kavlan-8": "2001:660:4406:694:2::14", "kavlan-9": "2001:660:4406:695:2::14" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:14", + "kavlan-11": "2001:660:4406:1a0:602:1:0:14", + "kavlan-12": "2001:660:4406:2a0:602:1:0:14", + "kavlan-13": "2001:660:4406:4a0:602:1:0:14", + "kavlan-14": "2001:660:4406:5a0:602:1:0:14", + "kavlan-16": "2001:660:4406:7a0:602:1:0:14", + "kavlan-17": "2001:660:4406:9a0:602:1:0:14", + "kavlan-18": "2001:660:4406:8a0:602:1:0:14", + "kavlan-2": "2001:660:4406:681:2:1:0:14", + "kavlan-20": "2001:660:4406:3a0:602:1:0:14", + "kavlan-21": "2001:660:4406:6a0:602:1:0:14", + "kavlan-3": "2001:660:4406:682:2:1:0:14", + "kavlan-4": "2001:660:4406:690:2:1:0:14", + "kavlan-5": "2001:660:4406:691:2:1:0:14", + "kavlan-6": "2001:660:4406:692:2:1:0:14", + "kavlan-7": "2001:660:4406:693:2:1:0:14", + "kavlan-8": "2001:660:4406:694:2:1:0:14", + "kavlan-9": "2001:660:4406:695:2:1:0:14" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.20", + "ip6": "2001:660:4406:600:2:1:0:14", + "kavlan": true, "mac": "24:6e:96:6a:50:12", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-20-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/20", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json index ff6a66ed36a..991f93fd6ba 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.21", "kavlan-8": "10.45.1.21", "kavlan-9": "10.45.65.21" + }, + "eth1": { + "kavlan-1": "192.168.194.21", + "kavlan-11": "10.7.241.121", + "kavlan-12": "10.11.241.121", + "kavlan-13": "10.15.241.121", + "kavlan-14": "10.19.241.121", + "kavlan-16": "10.27.241.121", + "kavlan-17": "10.31.241.121", + "kavlan-18": "10.35.241.121", + "kavlan-2": "192.168.210.21", + "kavlan-20": "10.43.241.121", + "kavlan-21": "10.47.241.121", + "kavlan-3": "192.168.226.21", + "kavlan-4": "10.44.2.21", + "kavlan-5": "10.44.66.21", + "kavlan-6": "10.44.130.21", + "kavlan-7": "10.44.194.21", + "kavlan-8": "10.45.2.21", + "kavlan-9": "10.45.66.21" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::15", "kavlan-8": "2001:660:4406:694:2::15", "kavlan-9": "2001:660:4406:695:2::15" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:15", + "kavlan-11": "2001:660:4406:1a0:602:1:0:15", + "kavlan-12": "2001:660:4406:2a0:602:1:0:15", + "kavlan-13": "2001:660:4406:4a0:602:1:0:15", + "kavlan-14": "2001:660:4406:5a0:602:1:0:15", + "kavlan-16": "2001:660:4406:7a0:602:1:0:15", + "kavlan-17": "2001:660:4406:9a0:602:1:0:15", + "kavlan-18": "2001:660:4406:8a0:602:1:0:15", + "kavlan-2": "2001:660:4406:681:2:1:0:15", + "kavlan-20": "2001:660:4406:3a0:602:1:0:15", + "kavlan-21": "2001:660:4406:6a0:602:1:0:15", + "kavlan-3": "2001:660:4406:682:2:1:0:15", + "kavlan-4": "2001:660:4406:690:2:1:0:15", + "kavlan-5": "2001:660:4406:691:2:1:0:15", + "kavlan-6": "2001:660:4406:692:2:1:0:15", + "kavlan-7": "2001:660:4406:693:2:1:0:15", + "kavlan-8": "2001:660:4406:694:2:1:0:15", + "kavlan-9": "2001:660:4406:695:2:1:0:15" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.21", + "ip6": "2001:660:4406:600:2:1:0:15", + "kavlan": true, "mac": "24:6e:96:6a:c9:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-21-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/21", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json index 084c56c2f41..32dfd888cbd 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.22", "kavlan-8": "10.45.1.22", "kavlan-9": "10.45.65.22" + }, + "eth1": { + "kavlan-1": "192.168.194.22", + "kavlan-11": "10.7.241.122", + "kavlan-12": "10.11.241.122", + "kavlan-13": "10.15.241.122", + "kavlan-14": "10.19.241.122", + "kavlan-16": "10.27.241.122", + "kavlan-17": "10.31.241.122", + "kavlan-18": "10.35.241.122", + "kavlan-2": "192.168.210.22", + "kavlan-20": "10.43.241.122", + "kavlan-21": "10.47.241.122", + "kavlan-3": "192.168.226.22", + "kavlan-4": "10.44.2.22", + "kavlan-5": "10.44.66.22", + "kavlan-6": "10.44.130.22", + "kavlan-7": "10.44.194.22", + "kavlan-8": "10.45.2.22", + "kavlan-9": "10.45.66.22" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::16", "kavlan-8": "2001:660:4406:694:2::16", "kavlan-9": "2001:660:4406:695:2::16" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:16", + "kavlan-11": "2001:660:4406:1a0:602:1:0:16", + "kavlan-12": "2001:660:4406:2a0:602:1:0:16", + "kavlan-13": "2001:660:4406:4a0:602:1:0:16", + "kavlan-14": "2001:660:4406:5a0:602:1:0:16", + "kavlan-16": "2001:660:4406:7a0:602:1:0:16", + "kavlan-17": "2001:660:4406:9a0:602:1:0:16", + "kavlan-18": "2001:660:4406:8a0:602:1:0:16", + "kavlan-2": "2001:660:4406:681:2:1:0:16", + "kavlan-20": "2001:660:4406:3a0:602:1:0:16", + "kavlan-21": "2001:660:4406:6a0:602:1:0:16", + "kavlan-3": "2001:660:4406:682:2:1:0:16", + "kavlan-4": "2001:660:4406:690:2:1:0:16", + "kavlan-5": "2001:660:4406:691:2:1:0:16", + "kavlan-6": "2001:660:4406:692:2:1:0:16", + "kavlan-7": "2001:660:4406:693:2:1:0:16", + "kavlan-8": "2001:660:4406:694:2:1:0:16", + "kavlan-9": "2001:660:4406:695:2:1:0:16" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.22", + "ip6": "2001:660:4406:600:2:1:0:16", + "kavlan": true, "mac": "24:6e:96:6a:d3:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-22-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/22", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json index 4881c288727..39beea725e8 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.23", "kavlan-8": "10.45.1.23", "kavlan-9": "10.45.65.23" + }, + "eth1": { + "kavlan-1": "192.168.194.23", + "kavlan-11": "10.7.241.123", + "kavlan-12": "10.11.241.123", + "kavlan-13": "10.15.241.123", + "kavlan-14": "10.19.241.123", + "kavlan-16": "10.27.241.123", + "kavlan-17": "10.31.241.123", + "kavlan-18": "10.35.241.123", + "kavlan-2": "192.168.210.23", + "kavlan-20": "10.43.241.123", + "kavlan-21": "10.47.241.123", + "kavlan-3": "192.168.226.23", + "kavlan-4": "10.44.2.23", + "kavlan-5": "10.44.66.23", + "kavlan-6": "10.44.130.23", + "kavlan-7": "10.44.194.23", + "kavlan-8": "10.45.2.23", + "kavlan-9": "10.45.66.23" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::17", "kavlan-8": "2001:660:4406:694:2::17", "kavlan-9": "2001:660:4406:695:2::17" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:17", + "kavlan-11": "2001:660:4406:1a0:602:1:0:17", + "kavlan-12": "2001:660:4406:2a0:602:1:0:17", + "kavlan-13": "2001:660:4406:4a0:602:1:0:17", + "kavlan-14": "2001:660:4406:5a0:602:1:0:17", + "kavlan-16": "2001:660:4406:7a0:602:1:0:17", + "kavlan-17": "2001:660:4406:9a0:602:1:0:17", + "kavlan-18": "2001:660:4406:8a0:602:1:0:17", + "kavlan-2": "2001:660:4406:681:2:1:0:17", + "kavlan-20": "2001:660:4406:3a0:602:1:0:17", + "kavlan-21": "2001:660:4406:6a0:602:1:0:17", + "kavlan-3": "2001:660:4406:682:2:1:0:17", + "kavlan-4": "2001:660:4406:690:2:1:0:17", + "kavlan-5": "2001:660:4406:691:2:1:0:17", + "kavlan-6": "2001:660:4406:692:2:1:0:17", + "kavlan-7": "2001:660:4406:693:2:1:0:17", + "kavlan-8": "2001:660:4406:694:2:1:0:17", + "kavlan-9": "2001:660:4406:695:2:1:0:17" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.23", + "ip6": "2001:660:4406:600:2:1:0:17", + "kavlan": true, "mac": "24:6e:96:6a:4e:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-23-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/23", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json index ff71f4c3751..4919bd26cfa 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.24", "kavlan-8": "10.45.1.24", "kavlan-9": "10.45.65.24" + }, + "eth1": { + "kavlan-1": "192.168.194.24", + "kavlan-11": "10.7.241.124", + "kavlan-12": "10.11.241.124", + "kavlan-13": "10.15.241.124", + "kavlan-14": "10.19.241.124", + "kavlan-16": "10.27.241.124", + "kavlan-17": "10.31.241.124", + "kavlan-18": "10.35.241.124", + "kavlan-2": "192.168.210.24", + "kavlan-20": "10.43.241.124", + "kavlan-21": "10.47.241.124", + "kavlan-3": "192.168.226.24", + "kavlan-4": "10.44.2.24", + "kavlan-5": "10.44.66.24", + "kavlan-6": "10.44.130.24", + "kavlan-7": "10.44.194.24", + "kavlan-8": "10.45.2.24", + "kavlan-9": "10.45.66.24" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::18", "kavlan-8": "2001:660:4406:694:2::18", "kavlan-9": "2001:660:4406:695:2::18" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:18", + "kavlan-11": "2001:660:4406:1a0:602:1:0:18", + "kavlan-12": "2001:660:4406:2a0:602:1:0:18", + "kavlan-13": "2001:660:4406:4a0:602:1:0:18", + "kavlan-14": "2001:660:4406:5a0:602:1:0:18", + "kavlan-16": "2001:660:4406:7a0:602:1:0:18", + "kavlan-17": "2001:660:4406:9a0:602:1:0:18", + "kavlan-18": "2001:660:4406:8a0:602:1:0:18", + "kavlan-2": "2001:660:4406:681:2:1:0:18", + "kavlan-20": "2001:660:4406:3a0:602:1:0:18", + "kavlan-21": "2001:660:4406:6a0:602:1:0:18", + "kavlan-3": "2001:660:4406:682:2:1:0:18", + "kavlan-4": "2001:660:4406:690:2:1:0:18", + "kavlan-5": "2001:660:4406:691:2:1:0:18", + "kavlan-6": "2001:660:4406:692:2:1:0:18", + "kavlan-7": "2001:660:4406:693:2:1:0:18", + "kavlan-8": "2001:660:4406:694:2:1:0:18", + "kavlan-9": "2001:660:4406:695:2:1:0:18" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.24", + "ip6": "2001:660:4406:600:2:1:0:18", + "kavlan": true, "mac": "24:6e:96:6a:cf:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-24-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/24", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json index df0ce3f4787..01b4566362a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.25", "kavlan-8": "10.45.1.25", "kavlan-9": "10.45.65.25" + }, + "eth1": { + "kavlan-1": "192.168.194.25", + "kavlan-11": "10.7.241.125", + "kavlan-12": "10.11.241.125", + "kavlan-13": "10.15.241.125", + "kavlan-14": "10.19.241.125", + "kavlan-16": "10.27.241.125", + "kavlan-17": "10.31.241.125", + "kavlan-18": "10.35.241.125", + "kavlan-2": "192.168.210.25", + "kavlan-20": "10.43.241.125", + "kavlan-21": "10.47.241.125", + "kavlan-3": "192.168.226.25", + "kavlan-4": "10.44.2.25", + "kavlan-5": "10.44.66.25", + "kavlan-6": "10.44.130.25", + "kavlan-7": "10.44.194.25", + "kavlan-8": "10.45.2.25", + "kavlan-9": "10.45.66.25" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::19", "kavlan-8": "2001:660:4406:694:2::19", "kavlan-9": "2001:660:4406:695:2::19" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:19", + "kavlan-11": "2001:660:4406:1a0:602:1:0:19", + "kavlan-12": "2001:660:4406:2a0:602:1:0:19", + "kavlan-13": "2001:660:4406:4a0:602:1:0:19", + "kavlan-14": "2001:660:4406:5a0:602:1:0:19", + "kavlan-16": "2001:660:4406:7a0:602:1:0:19", + "kavlan-17": "2001:660:4406:9a0:602:1:0:19", + "kavlan-18": "2001:660:4406:8a0:602:1:0:19", + "kavlan-2": "2001:660:4406:681:2:1:0:19", + "kavlan-20": "2001:660:4406:3a0:602:1:0:19", + "kavlan-21": "2001:660:4406:6a0:602:1:0:19", + "kavlan-3": "2001:660:4406:682:2:1:0:19", + "kavlan-4": "2001:660:4406:690:2:1:0:19", + "kavlan-5": "2001:660:4406:691:2:1:0:19", + "kavlan-6": "2001:660:4406:692:2:1:0:19", + "kavlan-7": "2001:660:4406:693:2:1:0:19", + "kavlan-8": "2001:660:4406:694:2:1:0:19", + "kavlan-9": "2001:660:4406:695:2:1:0:19" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.25", + "ip6": "2001:660:4406:600:2:1:0:19", + "kavlan": true, "mac": "24:6e:96:6a:48:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-25-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/25", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json index a6a54018215..42182b5beb8 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.26", "kavlan-8": "10.45.1.26", "kavlan-9": "10.45.65.26" + }, + "eth1": { + "kavlan-1": "192.168.194.26", + "kavlan-11": "10.7.241.126", + "kavlan-12": "10.11.241.126", + "kavlan-13": "10.15.241.126", + "kavlan-14": "10.19.241.126", + "kavlan-16": "10.27.241.126", + "kavlan-17": "10.31.241.126", + "kavlan-18": "10.35.241.126", + "kavlan-2": "192.168.210.26", + "kavlan-20": "10.43.241.126", + "kavlan-21": "10.47.241.126", + "kavlan-3": "192.168.226.26", + "kavlan-4": "10.44.2.26", + "kavlan-5": "10.44.66.26", + "kavlan-6": "10.44.130.26", + "kavlan-7": "10.44.194.26", + "kavlan-8": "10.45.2.26", + "kavlan-9": "10.45.66.26" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1a", "kavlan-8": "2001:660:4406:694:2::1a", "kavlan-9": "2001:660:4406:695:2::1a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1a", + "kavlan-2": "2001:660:4406:681:2:1:0:1a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1a", + "kavlan-3": "2001:660:4406:682:2:1:0:1a", + "kavlan-4": "2001:660:4406:690:2:1:0:1a", + "kavlan-5": "2001:660:4406:691:2:1:0:1a", + "kavlan-6": "2001:660:4406:692:2:1:0:1a", + "kavlan-7": "2001:660:4406:693:2:1:0:1a", + "kavlan-8": "2001:660:4406:694:2:1:0:1a", + "kavlan-9": "2001:660:4406:695:2:1:0:1a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.26", + "ip6": "2001:660:4406:600:2:1:0:1a", + "kavlan": true, "mac": "24:6e:96:6a:4e:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-26-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/26", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json index 37a7208a4a4..b080d9fa8bb 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.27", "kavlan-8": "10.45.1.27", "kavlan-9": "10.45.65.27" + }, + "eth1": { + "kavlan-1": "192.168.194.27", + "kavlan-11": "10.7.241.127", + "kavlan-12": "10.11.241.127", + "kavlan-13": "10.15.241.127", + "kavlan-14": "10.19.241.127", + "kavlan-16": "10.27.241.127", + "kavlan-17": "10.31.241.127", + "kavlan-18": "10.35.241.127", + "kavlan-2": "192.168.210.27", + "kavlan-20": "10.43.241.127", + "kavlan-21": "10.47.241.127", + "kavlan-3": "192.168.226.27", + "kavlan-4": "10.44.2.27", + "kavlan-5": "10.44.66.27", + "kavlan-6": "10.44.130.27", + "kavlan-7": "10.44.194.27", + "kavlan-8": "10.45.2.27", + "kavlan-9": "10.45.66.27" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1b", "kavlan-8": "2001:660:4406:694:2::1b", "kavlan-9": "2001:660:4406:695:2::1b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1b", + "kavlan-2": "2001:660:4406:681:2:1:0:1b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1b", + "kavlan-3": "2001:660:4406:682:2:1:0:1b", + "kavlan-4": "2001:660:4406:690:2:1:0:1b", + "kavlan-5": "2001:660:4406:691:2:1:0:1b", + "kavlan-6": "2001:660:4406:692:2:1:0:1b", + "kavlan-7": "2001:660:4406:693:2:1:0:1b", + "kavlan-8": "2001:660:4406:694:2:1:0:1b", + "kavlan-9": "2001:660:4406:695:2:1:0:1b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.27", + "ip6": "2001:660:4406:600:2:1:0:1b", + "kavlan": true, "mac": "24:6e:96:6a:d9:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-27-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/27", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json index d5b60e4b22f..f6374ff43ed 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.28", "kavlan-8": "10.45.1.28", "kavlan-9": "10.45.65.28" + }, + "eth1": { + "kavlan-1": "192.168.194.28", + "kavlan-11": "10.7.241.128", + "kavlan-12": "10.11.241.128", + "kavlan-13": "10.15.241.128", + "kavlan-14": "10.19.241.128", + "kavlan-16": "10.27.241.128", + "kavlan-17": "10.31.241.128", + "kavlan-18": "10.35.241.128", + "kavlan-2": "192.168.210.28", + "kavlan-20": "10.43.241.128", + "kavlan-21": "10.47.241.128", + "kavlan-3": "192.168.226.28", + "kavlan-4": "10.44.2.28", + "kavlan-5": "10.44.66.28", + "kavlan-6": "10.44.130.28", + "kavlan-7": "10.44.194.28", + "kavlan-8": "10.45.2.28", + "kavlan-9": "10.45.66.28" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1c", "kavlan-8": "2001:660:4406:694:2::1c", "kavlan-9": "2001:660:4406:695:2::1c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1c", + "kavlan-2": "2001:660:4406:681:2:1:0:1c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1c", + "kavlan-3": "2001:660:4406:682:2:1:0:1c", + "kavlan-4": "2001:660:4406:690:2:1:0:1c", + "kavlan-5": "2001:660:4406:691:2:1:0:1c", + "kavlan-6": "2001:660:4406:692:2:1:0:1c", + "kavlan-7": "2001:660:4406:693:2:1:0:1c", + "kavlan-8": "2001:660:4406:694:2:1:0:1c", + "kavlan-9": "2001:660:4406:695:2:1:0:1c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.28", + "ip6": "2001:660:4406:600:2:1:0:1c", + "kavlan": true, "mac": "24:6e:96:6a:ca:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-28-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/28", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json index a728bca1d2f..5f3066215dc 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.29", "kavlan-8": "10.45.1.29", "kavlan-9": "10.45.65.29" + }, + "eth1": { + "kavlan-1": "192.168.194.29", + "kavlan-11": "10.7.241.129", + "kavlan-12": "10.11.241.129", + "kavlan-13": "10.15.241.129", + "kavlan-14": "10.19.241.129", + "kavlan-16": "10.27.241.129", + "kavlan-17": "10.31.241.129", + "kavlan-18": "10.35.241.129", + "kavlan-2": "192.168.210.29", + "kavlan-20": "10.43.241.129", + "kavlan-21": "10.47.241.129", + "kavlan-3": "192.168.226.29", + "kavlan-4": "10.44.2.29", + "kavlan-5": "10.44.66.29", + "kavlan-6": "10.44.130.29", + "kavlan-7": "10.44.194.29", + "kavlan-8": "10.45.2.29", + "kavlan-9": "10.45.66.29" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1d", "kavlan-8": "2001:660:4406:694:2::1d", "kavlan-9": "2001:660:4406:695:2::1d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1d", + "kavlan-2": "2001:660:4406:681:2:1:0:1d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1d", + "kavlan-3": "2001:660:4406:682:2:1:0:1d", + "kavlan-4": "2001:660:4406:690:2:1:0:1d", + "kavlan-5": "2001:660:4406:691:2:1:0:1d", + "kavlan-6": "2001:660:4406:692:2:1:0:1d", + "kavlan-7": "2001:660:4406:693:2:1:0:1d", + "kavlan-8": "2001:660:4406:694:2:1:0:1d", + "kavlan-9": "2001:660:4406:695:2:1:0:1d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.29", + "ip6": "2001:660:4406:600:2:1:0:1d", + "kavlan": true, "mac": "24:6e:96:6a:d8:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-29-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/29", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json index bda941dd4b0..13678b64492 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.3", "kavlan-8": "10.45.1.3", "kavlan-9": "10.45.65.3" + }, + "eth1": { + "kavlan-1": "192.168.194.3", + "kavlan-11": "10.7.241.103", + "kavlan-12": "10.11.241.103", + "kavlan-13": "10.15.241.103", + "kavlan-14": "10.19.241.103", + "kavlan-16": "10.27.241.103", + "kavlan-17": "10.31.241.103", + "kavlan-18": "10.35.241.103", + "kavlan-2": "192.168.210.3", + "kavlan-20": "10.43.241.103", + "kavlan-21": "10.47.241.103", + "kavlan-3": "192.168.226.3", + "kavlan-4": "10.44.2.3", + "kavlan-5": "10.44.66.3", + "kavlan-6": "10.44.130.3", + "kavlan-7": "10.44.194.3", + "kavlan-8": "10.45.2.3", + "kavlan-9": "10.45.66.3" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::3", "kavlan-8": "2001:660:4406:694:2::3", "kavlan-9": "2001:660:4406:695:2::3" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:3", + "kavlan-11": "2001:660:4406:1a0:602:1:0:3", + "kavlan-12": "2001:660:4406:2a0:602:1:0:3", + "kavlan-13": "2001:660:4406:4a0:602:1:0:3", + "kavlan-14": "2001:660:4406:5a0:602:1:0:3", + "kavlan-16": "2001:660:4406:7a0:602:1:0:3", + "kavlan-17": "2001:660:4406:9a0:602:1:0:3", + "kavlan-18": "2001:660:4406:8a0:602:1:0:3", + "kavlan-2": "2001:660:4406:681:2:1:0:3", + "kavlan-20": "2001:660:4406:3a0:602:1:0:3", + "kavlan-21": "2001:660:4406:6a0:602:1:0:3", + "kavlan-3": "2001:660:4406:682:2:1:0:3", + "kavlan-4": "2001:660:4406:690:2:1:0:3", + "kavlan-5": "2001:660:4406:691:2:1:0:3", + "kavlan-6": "2001:660:4406:692:2:1:0:3", + "kavlan-7": "2001:660:4406:693:2:1:0:3", + "kavlan-8": "2001:660:4406:694:2:1:0:3", + "kavlan-9": "2001:660:4406:695:2:1:0:3" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.3", + "ip6": "2001:660:4406:600:2:1:0:3", + "kavlan": true, "mac": "24:6e:96:6a:d7:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-3-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/3", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json index f17a4ccc750..7bd9b7b861e 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.30", "kavlan-8": "10.45.1.30", "kavlan-9": "10.45.65.30" + }, + "eth1": { + "kavlan-1": "192.168.194.30", + "kavlan-11": "10.7.241.130", + "kavlan-12": "10.11.241.130", + "kavlan-13": "10.15.241.130", + "kavlan-14": "10.19.241.130", + "kavlan-16": "10.27.241.130", + "kavlan-17": "10.31.241.130", + "kavlan-18": "10.35.241.130", + "kavlan-2": "192.168.210.30", + "kavlan-20": "10.43.241.130", + "kavlan-21": "10.47.241.130", + "kavlan-3": "192.168.226.30", + "kavlan-4": "10.44.2.30", + "kavlan-5": "10.44.66.30", + "kavlan-6": "10.44.130.30", + "kavlan-7": "10.44.194.30", + "kavlan-8": "10.45.2.30", + "kavlan-9": "10.45.66.30" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1e", "kavlan-8": "2001:660:4406:694:2::1e", "kavlan-9": "2001:660:4406:695:2::1e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1e", + "kavlan-2": "2001:660:4406:681:2:1:0:1e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1e", + "kavlan-3": "2001:660:4406:682:2:1:0:1e", + "kavlan-4": "2001:660:4406:690:2:1:0:1e", + "kavlan-5": "2001:660:4406:691:2:1:0:1e", + "kavlan-6": "2001:660:4406:692:2:1:0:1e", + "kavlan-7": "2001:660:4406:693:2:1:0:1e", + "kavlan-8": "2001:660:4406:694:2:1:0:1e", + "kavlan-9": "2001:660:4406:695:2:1:0:1e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.30", + "ip6": "2001:660:4406:600:2:1:0:1e", + "kavlan": true, "mac": "24:6e:96:6a:51:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-30-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/30", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json index 074c4c7b49a..1c2cd030bd1 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.31", "kavlan-8": "10.45.1.31", "kavlan-9": "10.45.65.31" + }, + "eth1": { + "kavlan-1": "192.168.194.31", + "kavlan-11": "10.7.241.131", + "kavlan-12": "10.11.241.131", + "kavlan-13": "10.15.241.131", + "kavlan-14": "10.19.241.131", + "kavlan-16": "10.27.241.131", + "kavlan-17": "10.31.241.131", + "kavlan-18": "10.35.241.131", + "kavlan-2": "192.168.210.31", + "kavlan-20": "10.43.241.131", + "kavlan-21": "10.47.241.131", + "kavlan-3": "192.168.226.31", + "kavlan-4": "10.44.2.31", + "kavlan-5": "10.44.66.31", + "kavlan-6": "10.44.130.31", + "kavlan-7": "10.44.194.31", + "kavlan-8": "10.45.2.31", + "kavlan-9": "10.45.66.31" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1f", "kavlan-8": "2001:660:4406:694:2::1f", "kavlan-9": "2001:660:4406:695:2::1f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1f", + "kavlan-2": "2001:660:4406:681:2:1:0:1f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1f", + "kavlan-3": "2001:660:4406:682:2:1:0:1f", + "kavlan-4": "2001:660:4406:690:2:1:0:1f", + "kavlan-5": "2001:660:4406:691:2:1:0:1f", + "kavlan-6": "2001:660:4406:692:2:1:0:1f", + "kavlan-7": "2001:660:4406:693:2:1:0:1f", + "kavlan-8": "2001:660:4406:694:2:1:0:1f", + "kavlan-9": "2001:660:4406:695:2:1:0:1f" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.31", + "ip6": "2001:660:4406:600:2:1:0:1f", + "kavlan": true, "mac": "24:6e:96:6a:d8:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-31-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/31", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json index 67661503b4e..63c0e726e4d 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.32", "kavlan-8": "10.45.1.32", "kavlan-9": "10.45.65.32" + }, + "eth1": { + "kavlan-1": "192.168.194.32", + "kavlan-11": "10.7.241.132", + "kavlan-12": "10.11.241.132", + "kavlan-13": "10.15.241.132", + "kavlan-14": "10.19.241.132", + "kavlan-16": "10.27.241.132", + "kavlan-17": "10.31.241.132", + "kavlan-18": "10.35.241.132", + "kavlan-2": "192.168.210.32", + "kavlan-20": "10.43.241.132", + "kavlan-21": "10.47.241.132", + "kavlan-3": "192.168.226.32", + "kavlan-4": "10.44.2.32", + "kavlan-5": "10.44.66.32", + "kavlan-6": "10.44.130.32", + "kavlan-7": "10.44.194.32", + "kavlan-8": "10.45.2.32", + "kavlan-9": "10.45.66.32" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::20", "kavlan-8": "2001:660:4406:694:2::20", "kavlan-9": "2001:660:4406:695:2::20" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:20", + "kavlan-11": "2001:660:4406:1a0:602:1:0:20", + "kavlan-12": "2001:660:4406:2a0:602:1:0:20", + "kavlan-13": "2001:660:4406:4a0:602:1:0:20", + "kavlan-14": "2001:660:4406:5a0:602:1:0:20", + "kavlan-16": "2001:660:4406:7a0:602:1:0:20", + "kavlan-17": "2001:660:4406:9a0:602:1:0:20", + "kavlan-18": "2001:660:4406:8a0:602:1:0:20", + "kavlan-2": "2001:660:4406:681:2:1:0:20", + "kavlan-20": "2001:660:4406:3a0:602:1:0:20", + "kavlan-21": "2001:660:4406:6a0:602:1:0:20", + "kavlan-3": "2001:660:4406:682:2:1:0:20", + "kavlan-4": "2001:660:4406:690:2:1:0:20", + "kavlan-5": "2001:660:4406:691:2:1:0:20", + "kavlan-6": "2001:660:4406:692:2:1:0:20", + "kavlan-7": "2001:660:4406:693:2:1:0:20", + "kavlan-8": "2001:660:4406:694:2:1:0:20", + "kavlan-9": "2001:660:4406:695:2:1:0:20" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.32", + "ip6": "2001:660:4406:600:2:1:0:20", + "kavlan": true, "mac": "24:6e:96:6a:d6:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-32-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/32", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json index cc598d0401a..9abc9a90003 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.33", "kavlan-8": "10.45.1.33", "kavlan-9": "10.45.65.33" + }, + "eth1": { + "kavlan-1": "192.168.194.33", + "kavlan-11": "10.7.241.133", + "kavlan-12": "10.11.241.133", + "kavlan-13": "10.15.241.133", + "kavlan-14": "10.19.241.133", + "kavlan-16": "10.27.241.133", + "kavlan-17": "10.31.241.133", + "kavlan-18": "10.35.241.133", + "kavlan-2": "192.168.210.33", + "kavlan-20": "10.43.241.133", + "kavlan-21": "10.47.241.133", + "kavlan-3": "192.168.226.33", + "kavlan-4": "10.44.2.33", + "kavlan-5": "10.44.66.33", + "kavlan-6": "10.44.130.33", + "kavlan-7": "10.44.194.33", + "kavlan-8": "10.45.2.33", + "kavlan-9": "10.45.66.33" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::21", "kavlan-8": "2001:660:4406:694:2::21", "kavlan-9": "2001:660:4406:695:2::21" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:21", + "kavlan-11": "2001:660:4406:1a0:602:1:0:21", + "kavlan-12": "2001:660:4406:2a0:602:1:0:21", + "kavlan-13": "2001:660:4406:4a0:602:1:0:21", + "kavlan-14": "2001:660:4406:5a0:602:1:0:21", + "kavlan-16": "2001:660:4406:7a0:602:1:0:21", + "kavlan-17": "2001:660:4406:9a0:602:1:0:21", + "kavlan-18": "2001:660:4406:8a0:602:1:0:21", + "kavlan-2": "2001:660:4406:681:2:1:0:21", + "kavlan-20": "2001:660:4406:3a0:602:1:0:21", + "kavlan-21": "2001:660:4406:6a0:602:1:0:21", + "kavlan-3": "2001:660:4406:682:2:1:0:21", + "kavlan-4": "2001:660:4406:690:2:1:0:21", + "kavlan-5": "2001:660:4406:691:2:1:0:21", + "kavlan-6": "2001:660:4406:692:2:1:0:21", + "kavlan-7": "2001:660:4406:693:2:1:0:21", + "kavlan-8": "2001:660:4406:694:2:1:0:21", + "kavlan-9": "2001:660:4406:695:2:1:0:21" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.33", + "ip6": "2001:660:4406:600:2:1:0:21", + "kavlan": true, "mac": "24:6e:96:6a:4e:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-33-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/33", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json index 84ef304e1ad..c6534f6902a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.34", "kavlan-8": "10.45.1.34", "kavlan-9": "10.45.65.34" + }, + "eth1": { + "kavlan-1": "192.168.194.34", + "kavlan-11": "10.7.241.134", + "kavlan-12": "10.11.241.134", + "kavlan-13": "10.15.241.134", + "kavlan-14": "10.19.241.134", + "kavlan-16": "10.27.241.134", + "kavlan-17": "10.31.241.134", + "kavlan-18": "10.35.241.134", + "kavlan-2": "192.168.210.34", + "kavlan-20": "10.43.241.134", + "kavlan-21": "10.47.241.134", + "kavlan-3": "192.168.226.34", + "kavlan-4": "10.44.2.34", + "kavlan-5": "10.44.66.34", + "kavlan-6": "10.44.130.34", + "kavlan-7": "10.44.194.34", + "kavlan-8": "10.45.2.34", + "kavlan-9": "10.45.66.34" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::22", "kavlan-8": "2001:660:4406:694:2::22", "kavlan-9": "2001:660:4406:695:2::22" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:22", + "kavlan-11": "2001:660:4406:1a0:602:1:0:22", + "kavlan-12": "2001:660:4406:2a0:602:1:0:22", + "kavlan-13": "2001:660:4406:4a0:602:1:0:22", + "kavlan-14": "2001:660:4406:5a0:602:1:0:22", + "kavlan-16": "2001:660:4406:7a0:602:1:0:22", + "kavlan-17": "2001:660:4406:9a0:602:1:0:22", + "kavlan-18": "2001:660:4406:8a0:602:1:0:22", + "kavlan-2": "2001:660:4406:681:2:1:0:22", + "kavlan-20": "2001:660:4406:3a0:602:1:0:22", + "kavlan-21": "2001:660:4406:6a0:602:1:0:22", + "kavlan-3": "2001:660:4406:682:2:1:0:22", + "kavlan-4": "2001:660:4406:690:2:1:0:22", + "kavlan-5": "2001:660:4406:691:2:1:0:22", + "kavlan-6": "2001:660:4406:692:2:1:0:22", + "kavlan-7": "2001:660:4406:693:2:1:0:22", + "kavlan-8": "2001:660:4406:694:2:1:0:22", + "kavlan-9": "2001:660:4406:695:2:1:0:22" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.34", + "ip6": "2001:660:4406:600:2:1:0:22", + "kavlan": true, "mac": "24:6e:96:6a:c9:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-34-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/34", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json index 120e47fe105..1bad5b56bf0 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.35", "kavlan-8": "10.45.1.35", "kavlan-9": "10.45.65.35" + }, + "eth1": { + "kavlan-1": "192.168.194.35", + "kavlan-11": "10.7.241.135", + "kavlan-12": "10.11.241.135", + "kavlan-13": "10.15.241.135", + "kavlan-14": "10.19.241.135", + "kavlan-16": "10.27.241.135", + "kavlan-17": "10.31.241.135", + "kavlan-18": "10.35.241.135", + "kavlan-2": "192.168.210.35", + "kavlan-20": "10.43.241.135", + "kavlan-21": "10.47.241.135", + "kavlan-3": "192.168.226.35", + "kavlan-4": "10.44.2.35", + "kavlan-5": "10.44.66.35", + "kavlan-6": "10.44.130.35", + "kavlan-7": "10.44.194.35", + "kavlan-8": "10.45.2.35", + "kavlan-9": "10.45.66.35" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::23", "kavlan-8": "2001:660:4406:694:2::23", "kavlan-9": "2001:660:4406:695:2::23" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:23", + "kavlan-11": "2001:660:4406:1a0:602:1:0:23", + "kavlan-12": "2001:660:4406:2a0:602:1:0:23", + "kavlan-13": "2001:660:4406:4a0:602:1:0:23", + "kavlan-14": "2001:660:4406:5a0:602:1:0:23", + "kavlan-16": "2001:660:4406:7a0:602:1:0:23", + "kavlan-17": "2001:660:4406:9a0:602:1:0:23", + "kavlan-18": "2001:660:4406:8a0:602:1:0:23", + "kavlan-2": "2001:660:4406:681:2:1:0:23", + "kavlan-20": "2001:660:4406:3a0:602:1:0:23", + "kavlan-21": "2001:660:4406:6a0:602:1:0:23", + "kavlan-3": "2001:660:4406:682:2:1:0:23", + "kavlan-4": "2001:660:4406:690:2:1:0:23", + "kavlan-5": "2001:660:4406:691:2:1:0:23", + "kavlan-6": "2001:660:4406:692:2:1:0:23", + "kavlan-7": "2001:660:4406:693:2:1:0:23", + "kavlan-8": "2001:660:4406:694:2:1:0:23", + "kavlan-9": "2001:660:4406:695:2:1:0:23" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.35", + "ip6": "2001:660:4406:600:2:1:0:23", + "kavlan": true, "mac": "24:6e:96:6a:d1:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-35-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/35", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json index f71750f0021..654a103cfc1 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.36", "kavlan-8": "10.45.1.36", "kavlan-9": "10.45.65.36" + }, + "eth1": { + "kavlan-1": "192.168.194.36", + "kavlan-11": "10.7.241.136", + "kavlan-12": "10.11.241.136", + "kavlan-13": "10.15.241.136", + "kavlan-14": "10.19.241.136", + "kavlan-16": "10.27.241.136", + "kavlan-17": "10.31.241.136", + "kavlan-18": "10.35.241.136", + "kavlan-2": "192.168.210.36", + "kavlan-20": "10.43.241.136", + "kavlan-21": "10.47.241.136", + "kavlan-3": "192.168.226.36", + "kavlan-4": "10.44.2.36", + "kavlan-5": "10.44.66.36", + "kavlan-6": "10.44.130.36", + "kavlan-7": "10.44.194.36", + "kavlan-8": "10.45.2.36", + "kavlan-9": "10.45.66.36" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::24", "kavlan-8": "2001:660:4406:694:2::24", "kavlan-9": "2001:660:4406:695:2::24" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:24", + "kavlan-11": "2001:660:4406:1a0:602:1:0:24", + "kavlan-12": "2001:660:4406:2a0:602:1:0:24", + "kavlan-13": "2001:660:4406:4a0:602:1:0:24", + "kavlan-14": "2001:660:4406:5a0:602:1:0:24", + "kavlan-16": "2001:660:4406:7a0:602:1:0:24", + "kavlan-17": "2001:660:4406:9a0:602:1:0:24", + "kavlan-18": "2001:660:4406:8a0:602:1:0:24", + "kavlan-2": "2001:660:4406:681:2:1:0:24", + "kavlan-20": "2001:660:4406:3a0:602:1:0:24", + "kavlan-21": "2001:660:4406:6a0:602:1:0:24", + "kavlan-3": "2001:660:4406:682:2:1:0:24", + "kavlan-4": "2001:660:4406:690:2:1:0:24", + "kavlan-5": "2001:660:4406:691:2:1:0:24", + "kavlan-6": "2001:660:4406:692:2:1:0:24", + "kavlan-7": "2001:660:4406:693:2:1:0:24", + "kavlan-8": "2001:660:4406:694:2:1:0:24", + "kavlan-9": "2001:660:4406:695:2:1:0:24" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.36", + "ip6": "2001:660:4406:600:2:1:0:24", + "kavlan": true, "mac": "24:6e:96:6a:56:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-36-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/36", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json index 63a009ecd86..139513bb69a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.37", "kavlan-8": "10.45.1.37", "kavlan-9": "10.45.65.37" + }, + "eth1": { + "kavlan-1": "192.168.194.37", + "kavlan-11": "10.7.241.137", + "kavlan-12": "10.11.241.137", + "kavlan-13": "10.15.241.137", + "kavlan-14": "10.19.241.137", + "kavlan-16": "10.27.241.137", + "kavlan-17": "10.31.241.137", + "kavlan-18": "10.35.241.137", + "kavlan-2": "192.168.210.37", + "kavlan-20": "10.43.241.137", + "kavlan-21": "10.47.241.137", + "kavlan-3": "192.168.226.37", + "kavlan-4": "10.44.2.37", + "kavlan-5": "10.44.66.37", + "kavlan-6": "10.44.130.37", + "kavlan-7": "10.44.194.37", + "kavlan-8": "10.45.2.37", + "kavlan-9": "10.45.66.37" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::25", "kavlan-8": "2001:660:4406:694:2::25", "kavlan-9": "2001:660:4406:695:2::25" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:25", + "kavlan-11": "2001:660:4406:1a0:602:1:0:25", + "kavlan-12": "2001:660:4406:2a0:602:1:0:25", + "kavlan-13": "2001:660:4406:4a0:602:1:0:25", + "kavlan-14": "2001:660:4406:5a0:602:1:0:25", + "kavlan-16": "2001:660:4406:7a0:602:1:0:25", + "kavlan-17": "2001:660:4406:9a0:602:1:0:25", + "kavlan-18": "2001:660:4406:8a0:602:1:0:25", + "kavlan-2": "2001:660:4406:681:2:1:0:25", + "kavlan-20": "2001:660:4406:3a0:602:1:0:25", + "kavlan-21": "2001:660:4406:6a0:602:1:0:25", + "kavlan-3": "2001:660:4406:682:2:1:0:25", + "kavlan-4": "2001:660:4406:690:2:1:0:25", + "kavlan-5": "2001:660:4406:691:2:1:0:25", + "kavlan-6": "2001:660:4406:692:2:1:0:25", + "kavlan-7": "2001:660:4406:693:2:1:0:25", + "kavlan-8": "2001:660:4406:694:2:1:0:25", + "kavlan-9": "2001:660:4406:695:2:1:0:25" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.37", + "ip6": "2001:660:4406:600:2:1:0:25", + "kavlan": true, "mac": "24:6e:96:6a:cc:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-37-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/37", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json index cca8281d277..74c467b56e0 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.38", "kavlan-8": "10.45.1.38", "kavlan-9": "10.45.65.38" + }, + "eth1": { + "kavlan-1": "192.168.194.38", + "kavlan-11": "10.7.241.138", + "kavlan-12": "10.11.241.138", + "kavlan-13": "10.15.241.138", + "kavlan-14": "10.19.241.138", + "kavlan-16": "10.27.241.138", + "kavlan-17": "10.31.241.138", + "kavlan-18": "10.35.241.138", + "kavlan-2": "192.168.210.38", + "kavlan-20": "10.43.241.138", + "kavlan-21": "10.47.241.138", + "kavlan-3": "192.168.226.38", + "kavlan-4": "10.44.2.38", + "kavlan-5": "10.44.66.38", + "kavlan-6": "10.44.130.38", + "kavlan-7": "10.44.194.38", + "kavlan-8": "10.45.2.38", + "kavlan-9": "10.45.66.38" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::26", "kavlan-8": "2001:660:4406:694:2::26", "kavlan-9": "2001:660:4406:695:2::26" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:26", + "kavlan-11": "2001:660:4406:1a0:602:1:0:26", + "kavlan-12": "2001:660:4406:2a0:602:1:0:26", + "kavlan-13": "2001:660:4406:4a0:602:1:0:26", + "kavlan-14": "2001:660:4406:5a0:602:1:0:26", + "kavlan-16": "2001:660:4406:7a0:602:1:0:26", + "kavlan-17": "2001:660:4406:9a0:602:1:0:26", + "kavlan-18": "2001:660:4406:8a0:602:1:0:26", + "kavlan-2": "2001:660:4406:681:2:1:0:26", + "kavlan-20": "2001:660:4406:3a0:602:1:0:26", + "kavlan-21": "2001:660:4406:6a0:602:1:0:26", + "kavlan-3": "2001:660:4406:682:2:1:0:26", + "kavlan-4": "2001:660:4406:690:2:1:0:26", + "kavlan-5": "2001:660:4406:691:2:1:0:26", + "kavlan-6": "2001:660:4406:692:2:1:0:26", + "kavlan-7": "2001:660:4406:693:2:1:0:26", + "kavlan-8": "2001:660:4406:694:2:1:0:26", + "kavlan-9": "2001:660:4406:695:2:1:0:26" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.38", + "ip6": "2001:660:4406:600:2:1:0:26", + "kavlan": true, "mac": "24:6e:96:6a:d7:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-38-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/38", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json index 1b275ca3957..52831b90714 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.39", "kavlan-8": "10.45.1.39", "kavlan-9": "10.45.65.39" + }, + "eth1": { + "kavlan-1": "192.168.194.39", + "kavlan-11": "10.7.241.139", + "kavlan-12": "10.11.241.139", + "kavlan-13": "10.15.241.139", + "kavlan-14": "10.19.241.139", + "kavlan-16": "10.27.241.139", + "kavlan-17": "10.31.241.139", + "kavlan-18": "10.35.241.139", + "kavlan-2": "192.168.210.39", + "kavlan-20": "10.43.241.139", + "kavlan-21": "10.47.241.139", + "kavlan-3": "192.168.226.39", + "kavlan-4": "10.44.2.39", + "kavlan-5": "10.44.66.39", + "kavlan-6": "10.44.130.39", + "kavlan-7": "10.44.194.39", + "kavlan-8": "10.45.2.39", + "kavlan-9": "10.45.66.39" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::27", "kavlan-8": "2001:660:4406:694:2::27", "kavlan-9": "2001:660:4406:695:2::27" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:27", + "kavlan-11": "2001:660:4406:1a0:602:1:0:27", + "kavlan-12": "2001:660:4406:2a0:602:1:0:27", + "kavlan-13": "2001:660:4406:4a0:602:1:0:27", + "kavlan-14": "2001:660:4406:5a0:602:1:0:27", + "kavlan-16": "2001:660:4406:7a0:602:1:0:27", + "kavlan-17": "2001:660:4406:9a0:602:1:0:27", + "kavlan-18": "2001:660:4406:8a0:602:1:0:27", + "kavlan-2": "2001:660:4406:681:2:1:0:27", + "kavlan-20": "2001:660:4406:3a0:602:1:0:27", + "kavlan-21": "2001:660:4406:6a0:602:1:0:27", + "kavlan-3": "2001:660:4406:682:2:1:0:27", + "kavlan-4": "2001:660:4406:690:2:1:0:27", + "kavlan-5": "2001:660:4406:691:2:1:0:27", + "kavlan-6": "2001:660:4406:692:2:1:0:27", + "kavlan-7": "2001:660:4406:693:2:1:0:27", + "kavlan-8": "2001:660:4406:694:2:1:0:27", + "kavlan-9": "2001:660:4406:695:2:1:0:27" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.39", + "ip6": "2001:660:4406:600:2:1:0:27", + "kavlan": true, "mac": "24:6e:96:6a:d1:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-39-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/39", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json index 5813bf464af..f783897770b 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.4", "kavlan-8": "10.45.1.4", "kavlan-9": "10.45.65.4" + }, + "eth1": { + "kavlan-1": "192.168.194.4", + "kavlan-11": "10.7.241.104", + "kavlan-12": "10.11.241.104", + "kavlan-13": "10.15.241.104", + "kavlan-14": "10.19.241.104", + "kavlan-16": "10.27.241.104", + "kavlan-17": "10.31.241.104", + "kavlan-18": "10.35.241.104", + "kavlan-2": "192.168.210.4", + "kavlan-20": "10.43.241.104", + "kavlan-21": "10.47.241.104", + "kavlan-3": "192.168.226.4", + "kavlan-4": "10.44.2.4", + "kavlan-5": "10.44.66.4", + "kavlan-6": "10.44.130.4", + "kavlan-7": "10.44.194.4", + "kavlan-8": "10.45.2.4", + "kavlan-9": "10.45.66.4" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::4", "kavlan-8": "2001:660:4406:694:2::4", "kavlan-9": "2001:660:4406:695:2::4" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:4", + "kavlan-11": "2001:660:4406:1a0:602:1:0:4", + "kavlan-12": "2001:660:4406:2a0:602:1:0:4", + "kavlan-13": "2001:660:4406:4a0:602:1:0:4", + "kavlan-14": "2001:660:4406:5a0:602:1:0:4", + "kavlan-16": "2001:660:4406:7a0:602:1:0:4", + "kavlan-17": "2001:660:4406:9a0:602:1:0:4", + "kavlan-18": "2001:660:4406:8a0:602:1:0:4", + "kavlan-2": "2001:660:4406:681:2:1:0:4", + "kavlan-20": "2001:660:4406:3a0:602:1:0:4", + "kavlan-21": "2001:660:4406:6a0:602:1:0:4", + "kavlan-3": "2001:660:4406:682:2:1:0:4", + "kavlan-4": "2001:660:4406:690:2:1:0:4", + "kavlan-5": "2001:660:4406:691:2:1:0:4", + "kavlan-6": "2001:660:4406:692:2:1:0:4", + "kavlan-7": "2001:660:4406:693:2:1:0:4", + "kavlan-8": "2001:660:4406:694:2:1:0:4", + "kavlan-9": "2001:660:4406:695:2:1:0:4" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.4", + "ip6": "2001:660:4406:600:2:1:0:4", + "kavlan": true, "mac": "24:6e:96:6a:d7:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-4-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/4", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json index 4ea369bd5f5..09b9e63b2f2 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.40", "kavlan-8": "10.45.1.40", "kavlan-9": "10.45.65.40" + }, + "eth1": { + "kavlan-1": "192.168.194.40", + "kavlan-11": "10.7.241.140", + "kavlan-12": "10.11.241.140", + "kavlan-13": "10.15.241.140", + "kavlan-14": "10.19.241.140", + "kavlan-16": "10.27.241.140", + "kavlan-17": "10.31.241.140", + "kavlan-18": "10.35.241.140", + "kavlan-2": "192.168.210.40", + "kavlan-20": "10.43.241.140", + "kavlan-21": "10.47.241.140", + "kavlan-3": "192.168.226.40", + "kavlan-4": "10.44.2.40", + "kavlan-5": "10.44.66.40", + "kavlan-6": "10.44.130.40", + "kavlan-7": "10.44.194.40", + "kavlan-8": "10.45.2.40", + "kavlan-9": "10.45.66.40" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::28", "kavlan-8": "2001:660:4406:694:2::28", "kavlan-9": "2001:660:4406:695:2::28" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:28", + "kavlan-11": "2001:660:4406:1a0:602:1:0:28", + "kavlan-12": "2001:660:4406:2a0:602:1:0:28", + "kavlan-13": "2001:660:4406:4a0:602:1:0:28", + "kavlan-14": "2001:660:4406:5a0:602:1:0:28", + "kavlan-16": "2001:660:4406:7a0:602:1:0:28", + "kavlan-17": "2001:660:4406:9a0:602:1:0:28", + "kavlan-18": "2001:660:4406:8a0:602:1:0:28", + "kavlan-2": "2001:660:4406:681:2:1:0:28", + "kavlan-20": "2001:660:4406:3a0:602:1:0:28", + "kavlan-21": "2001:660:4406:6a0:602:1:0:28", + "kavlan-3": "2001:660:4406:682:2:1:0:28", + "kavlan-4": "2001:660:4406:690:2:1:0:28", + "kavlan-5": "2001:660:4406:691:2:1:0:28", + "kavlan-6": "2001:660:4406:692:2:1:0:28", + "kavlan-7": "2001:660:4406:693:2:1:0:28", + "kavlan-8": "2001:660:4406:694:2:1:0:28", + "kavlan-9": "2001:660:4406:695:2:1:0:28" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.40", + "ip6": "2001:660:4406:600:2:1:0:28", + "kavlan": true, "mac": "24:6e:96:6a:4f:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-40-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/40", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json index a86faf6c3c4..b0563fe53b6 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.41", "kavlan-8": "10.45.1.41", "kavlan-9": "10.45.65.41" + }, + "eth1": { + "kavlan-1": "192.168.194.41", + "kavlan-11": "10.7.241.141", + "kavlan-12": "10.11.241.141", + "kavlan-13": "10.15.241.141", + "kavlan-14": "10.19.241.141", + "kavlan-16": "10.27.241.141", + "kavlan-17": "10.31.241.141", + "kavlan-18": "10.35.241.141", + "kavlan-2": "192.168.210.41", + "kavlan-20": "10.43.241.141", + "kavlan-21": "10.47.241.141", + "kavlan-3": "192.168.226.41", + "kavlan-4": "10.44.2.41", + "kavlan-5": "10.44.66.41", + "kavlan-6": "10.44.130.41", + "kavlan-7": "10.44.194.41", + "kavlan-8": "10.45.2.41", + "kavlan-9": "10.45.66.41" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::29", "kavlan-8": "2001:660:4406:694:2::29", "kavlan-9": "2001:660:4406:695:2::29" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:29", + "kavlan-11": "2001:660:4406:1a0:602:1:0:29", + "kavlan-12": "2001:660:4406:2a0:602:1:0:29", + "kavlan-13": "2001:660:4406:4a0:602:1:0:29", + "kavlan-14": "2001:660:4406:5a0:602:1:0:29", + "kavlan-16": "2001:660:4406:7a0:602:1:0:29", + "kavlan-17": "2001:660:4406:9a0:602:1:0:29", + "kavlan-18": "2001:660:4406:8a0:602:1:0:29", + "kavlan-2": "2001:660:4406:681:2:1:0:29", + "kavlan-20": "2001:660:4406:3a0:602:1:0:29", + "kavlan-21": "2001:660:4406:6a0:602:1:0:29", + "kavlan-3": "2001:660:4406:682:2:1:0:29", + "kavlan-4": "2001:660:4406:690:2:1:0:29", + "kavlan-5": "2001:660:4406:691:2:1:0:29", + "kavlan-6": "2001:660:4406:692:2:1:0:29", + "kavlan-7": "2001:660:4406:693:2:1:0:29", + "kavlan-8": "2001:660:4406:694:2:1:0:29", + "kavlan-9": "2001:660:4406:695:2:1:0:29" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.41", + "ip6": "2001:660:4406:600:2:1:0:29", + "kavlan": true, "mac": "24:6e:96:6a:49:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-41-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/41", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json index a57b56391db..27dc2723bf1 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.42", "kavlan-8": "10.45.1.42", "kavlan-9": "10.45.65.42" + }, + "eth1": { + "kavlan-1": "192.168.194.42", + "kavlan-11": "10.7.241.142", + "kavlan-12": "10.11.241.142", + "kavlan-13": "10.15.241.142", + "kavlan-14": "10.19.241.142", + "kavlan-16": "10.27.241.142", + "kavlan-17": "10.31.241.142", + "kavlan-18": "10.35.241.142", + "kavlan-2": "192.168.210.42", + "kavlan-20": "10.43.241.142", + "kavlan-21": "10.47.241.142", + "kavlan-3": "192.168.226.42", + "kavlan-4": "10.44.2.42", + "kavlan-5": "10.44.66.42", + "kavlan-6": "10.44.130.42", + "kavlan-7": "10.44.194.42", + "kavlan-8": "10.45.2.42", + "kavlan-9": "10.45.66.42" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2a", "kavlan-8": "2001:660:4406:694:2::2a", "kavlan-9": "2001:660:4406:695:2::2a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2a", + "kavlan-2": "2001:660:4406:681:2:1:0:2a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2a", + "kavlan-3": "2001:660:4406:682:2:1:0:2a", + "kavlan-4": "2001:660:4406:690:2:1:0:2a", + "kavlan-5": "2001:660:4406:691:2:1:0:2a", + "kavlan-6": "2001:660:4406:692:2:1:0:2a", + "kavlan-7": "2001:660:4406:693:2:1:0:2a", + "kavlan-8": "2001:660:4406:694:2:1:0:2a", + "kavlan-9": "2001:660:4406:695:2:1:0:2a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.42", + "ip6": "2001:660:4406:600:2:1:0:2a", + "kavlan": true, "mac": "24:6e:96:6a:4c:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-42-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/42", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json index 9f3f038f514..175ff23b067 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.43", "kavlan-8": "10.45.1.43", "kavlan-9": "10.45.65.43" + }, + "eth1": { + "kavlan-1": "192.168.194.43", + "kavlan-11": "10.7.241.143", + "kavlan-12": "10.11.241.143", + "kavlan-13": "10.15.241.143", + "kavlan-14": "10.19.241.143", + "kavlan-16": "10.27.241.143", + "kavlan-17": "10.31.241.143", + "kavlan-18": "10.35.241.143", + "kavlan-2": "192.168.210.43", + "kavlan-20": "10.43.241.143", + "kavlan-21": "10.47.241.143", + "kavlan-3": "192.168.226.43", + "kavlan-4": "10.44.2.43", + "kavlan-5": "10.44.66.43", + "kavlan-6": "10.44.130.43", + "kavlan-7": "10.44.194.43", + "kavlan-8": "10.45.2.43", + "kavlan-9": "10.45.66.43" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2b", "kavlan-8": "2001:660:4406:694:2::2b", "kavlan-9": "2001:660:4406:695:2::2b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2b", + "kavlan-2": "2001:660:4406:681:2:1:0:2b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2b", + "kavlan-3": "2001:660:4406:682:2:1:0:2b", + "kavlan-4": "2001:660:4406:690:2:1:0:2b", + "kavlan-5": "2001:660:4406:691:2:1:0:2b", + "kavlan-6": "2001:660:4406:692:2:1:0:2b", + "kavlan-7": "2001:660:4406:693:2:1:0:2b", + "kavlan-8": "2001:660:4406:694:2:1:0:2b", + "kavlan-9": "2001:660:4406:695:2:1:0:2b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.43", + "ip6": "2001:660:4406:600:2:1:0:2b", + "kavlan": true, "mac": "24:6e:96:6a:d0:82", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-43-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/43", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json index 5f7ff475ba9..7cafd4372f2 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.44", "kavlan-8": "10.45.1.44", "kavlan-9": "10.45.65.44" + }, + "eth1": { + "kavlan-1": "192.168.194.44", + "kavlan-11": "10.7.241.144", + "kavlan-12": "10.11.241.144", + "kavlan-13": "10.15.241.144", + "kavlan-14": "10.19.241.144", + "kavlan-16": "10.27.241.144", + "kavlan-17": "10.31.241.144", + "kavlan-18": "10.35.241.144", + "kavlan-2": "192.168.210.44", + "kavlan-20": "10.43.241.144", + "kavlan-21": "10.47.241.144", + "kavlan-3": "192.168.226.44", + "kavlan-4": "10.44.2.44", + "kavlan-5": "10.44.66.44", + "kavlan-6": "10.44.130.44", + "kavlan-7": "10.44.194.44", + "kavlan-8": "10.45.2.44", + "kavlan-9": "10.45.66.44" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2c", "kavlan-8": "2001:660:4406:694:2::2c", "kavlan-9": "2001:660:4406:695:2::2c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2c", + "kavlan-2": "2001:660:4406:681:2:1:0:2c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2c", + "kavlan-3": "2001:660:4406:682:2:1:0:2c", + "kavlan-4": "2001:660:4406:690:2:1:0:2c", + "kavlan-5": "2001:660:4406:691:2:1:0:2c", + "kavlan-6": "2001:660:4406:692:2:1:0:2c", + "kavlan-7": "2001:660:4406:693:2:1:0:2c", + "kavlan-8": "2001:660:4406:694:2:1:0:2c", + "kavlan-9": "2001:660:4406:695:2:1:0:2c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.44", + "ip6": "2001:660:4406:600:2:1:0:2c", + "kavlan": true, "mac": "24:6e:96:6a:63:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-44-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/44", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json index c2ddaf60642..f755037db01 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.45", "kavlan-8": "10.45.1.45", "kavlan-9": "10.45.65.45" + }, + "eth1": { + "kavlan-1": "192.168.194.45", + "kavlan-11": "10.7.241.145", + "kavlan-12": "10.11.241.145", + "kavlan-13": "10.15.241.145", + "kavlan-14": "10.19.241.145", + "kavlan-16": "10.27.241.145", + "kavlan-17": "10.31.241.145", + "kavlan-18": "10.35.241.145", + "kavlan-2": "192.168.210.45", + "kavlan-20": "10.43.241.145", + "kavlan-21": "10.47.241.145", + "kavlan-3": "192.168.226.45", + "kavlan-4": "10.44.2.45", + "kavlan-5": "10.44.66.45", + "kavlan-6": "10.44.130.45", + "kavlan-7": "10.44.194.45", + "kavlan-8": "10.45.2.45", + "kavlan-9": "10.45.66.45" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2d", "kavlan-8": "2001:660:4406:694:2::2d", "kavlan-9": "2001:660:4406:695:2::2d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2d", + "kavlan-2": "2001:660:4406:681:2:1:0:2d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2d", + "kavlan-3": "2001:660:4406:682:2:1:0:2d", + "kavlan-4": "2001:660:4406:690:2:1:0:2d", + "kavlan-5": "2001:660:4406:691:2:1:0:2d", + "kavlan-6": "2001:660:4406:692:2:1:0:2d", + "kavlan-7": "2001:660:4406:693:2:1:0:2d", + "kavlan-8": "2001:660:4406:694:2:1:0:2d", + "kavlan-9": "2001:660:4406:695:2:1:0:2d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.45", + "ip6": "2001:660:4406:600:2:1:0:2d", + "kavlan": true, "mac": "24:6e:96:6a:47:42", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-45-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/45", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json index 600c9b55584..8575ccd241b 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.46", "kavlan-8": "10.45.1.46", "kavlan-9": "10.45.65.46" + }, + "eth1": { + "kavlan-1": "192.168.194.46", + "kavlan-11": "10.7.241.146", + "kavlan-12": "10.11.241.146", + "kavlan-13": "10.15.241.146", + "kavlan-14": "10.19.241.146", + "kavlan-16": "10.27.241.146", + "kavlan-17": "10.31.241.146", + "kavlan-18": "10.35.241.146", + "kavlan-2": "192.168.210.46", + "kavlan-20": "10.43.241.146", + "kavlan-21": "10.47.241.146", + "kavlan-3": "192.168.226.46", + "kavlan-4": "10.44.2.46", + "kavlan-5": "10.44.66.46", + "kavlan-6": "10.44.130.46", + "kavlan-7": "10.44.194.46", + "kavlan-8": "10.45.2.46", + "kavlan-9": "10.45.66.46" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2e", "kavlan-8": "2001:660:4406:694:2::2e", "kavlan-9": "2001:660:4406:695:2::2e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2e", + "kavlan-2": "2001:660:4406:681:2:1:0:2e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2e", + "kavlan-3": "2001:660:4406:682:2:1:0:2e", + "kavlan-4": "2001:660:4406:690:2:1:0:2e", + "kavlan-5": "2001:660:4406:691:2:1:0:2e", + "kavlan-6": "2001:660:4406:692:2:1:0:2e", + "kavlan-7": "2001:660:4406:693:2:1:0:2e", + "kavlan-8": "2001:660:4406:694:2:1:0:2e", + "kavlan-9": "2001:660:4406:695:2:1:0:2e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.46", + "ip6": "2001:660:4406:600:2:1:0:2e", + "kavlan": true, "mac": "24:6e:96:6a:c9:aa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-46-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/46", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json index c88a250a70e..6934cd1f4de 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.47", "kavlan-8": "10.45.1.47", "kavlan-9": "10.45.65.47" + }, + "eth1": { + "kavlan-1": "192.168.194.47", + "kavlan-11": "10.7.241.147", + "kavlan-12": "10.11.241.147", + "kavlan-13": "10.15.241.147", + "kavlan-14": "10.19.241.147", + "kavlan-16": "10.27.241.147", + "kavlan-17": "10.31.241.147", + "kavlan-18": "10.35.241.147", + "kavlan-2": "192.168.210.47", + "kavlan-20": "10.43.241.147", + "kavlan-21": "10.47.241.147", + "kavlan-3": "192.168.226.47", + "kavlan-4": "10.44.2.47", + "kavlan-5": "10.44.66.47", + "kavlan-6": "10.44.130.47", + "kavlan-7": "10.44.194.47", + "kavlan-8": "10.45.2.47", + "kavlan-9": "10.45.66.47" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2f", "kavlan-8": "2001:660:4406:694:2::2f", "kavlan-9": "2001:660:4406:695:2::2f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2f", + "kavlan-2": "2001:660:4406:681:2:1:0:2f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2f", + "kavlan-3": "2001:660:4406:682:2:1:0:2f", + "kavlan-4": "2001:660:4406:690:2:1:0:2f", + "kavlan-5": "2001:660:4406:691:2:1:0:2f", + "kavlan-6": "2001:660:4406:692:2:1:0:2f", + "kavlan-7": "2001:660:4406:693:2:1:0:2f", + "kavlan-8": "2001:660:4406:694:2:1:0:2f", + "kavlan-9": "2001:660:4406:695:2:1:0:2f" } }, "main_memory": { @@ -142,18 +182,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.47", + "ip6": "2001:660:4406:600:2:1:0:2f", + "kavlan": true, "mac": "24:6e:96:6a:d1:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-47-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/47", "vendor": "Intel" }, { @@ -194,7 +239,7 @@ "device": "bmc", "enabled": true, "interface": "Ethernet", - "ip": "172.17.193.47", + "ip": "0.0.0.0", "kavlan": false, "mac": "50:9a:4c:a8:8d:9c", "management": true, diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json index 467c935c789..81ee06b5aba 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.48", "kavlan-8": "10.45.1.48", "kavlan-9": "10.45.65.48" + }, + "eth1": { + "kavlan-1": "192.168.194.48", + "kavlan-11": "10.7.241.148", + "kavlan-12": "10.11.241.148", + "kavlan-13": "10.15.241.148", + "kavlan-14": "10.19.241.148", + "kavlan-16": "10.27.241.148", + "kavlan-17": "10.31.241.148", + "kavlan-18": "10.35.241.148", + "kavlan-2": "192.168.210.48", + "kavlan-20": "10.43.241.148", + "kavlan-21": "10.47.241.148", + "kavlan-3": "192.168.226.48", + "kavlan-4": "10.44.2.48", + "kavlan-5": "10.44.66.48", + "kavlan-6": "10.44.130.48", + "kavlan-7": "10.44.194.48", + "kavlan-8": "10.45.2.48", + "kavlan-9": "10.45.66.48" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::30", "kavlan-8": "2001:660:4406:694:2::30", "kavlan-9": "2001:660:4406:695:2::30" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:30", + "kavlan-11": "2001:660:4406:1a0:602:1:0:30", + "kavlan-12": "2001:660:4406:2a0:602:1:0:30", + "kavlan-13": "2001:660:4406:4a0:602:1:0:30", + "kavlan-14": "2001:660:4406:5a0:602:1:0:30", + "kavlan-16": "2001:660:4406:7a0:602:1:0:30", + "kavlan-17": "2001:660:4406:9a0:602:1:0:30", + "kavlan-18": "2001:660:4406:8a0:602:1:0:30", + "kavlan-2": "2001:660:4406:681:2:1:0:30", + "kavlan-20": "2001:660:4406:3a0:602:1:0:30", + "kavlan-21": "2001:660:4406:6a0:602:1:0:30", + "kavlan-3": "2001:660:4406:682:2:1:0:30", + "kavlan-4": "2001:660:4406:690:2:1:0:30", + "kavlan-5": "2001:660:4406:691:2:1:0:30", + "kavlan-6": "2001:660:4406:692:2:1:0:30", + "kavlan-7": "2001:660:4406:693:2:1:0:30", + "kavlan-8": "2001:660:4406:694:2:1:0:30", + "kavlan-9": "2001:660:4406:695:2:1:0:30" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.48", + "ip6": "2001:660:4406:600:2:1:0:30", + "kavlan": true, "mac": "24:6e:96:6a:cf:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-48-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/48", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json index 56733e4b8fb..f40c2bd0713 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.5", "kavlan-8": "10.45.1.5", "kavlan-9": "10.45.65.5" + }, + "eth1": { + "kavlan-1": "192.168.194.5", + "kavlan-11": "10.7.241.105", + "kavlan-12": "10.11.241.105", + "kavlan-13": "10.15.241.105", + "kavlan-14": "10.19.241.105", + "kavlan-16": "10.27.241.105", + "kavlan-17": "10.31.241.105", + "kavlan-18": "10.35.241.105", + "kavlan-2": "192.168.210.5", + "kavlan-20": "10.43.241.105", + "kavlan-21": "10.47.241.105", + "kavlan-3": "192.168.226.5", + "kavlan-4": "10.44.2.5", + "kavlan-5": "10.44.66.5", + "kavlan-6": "10.44.130.5", + "kavlan-7": "10.44.194.5", + "kavlan-8": "10.45.2.5", + "kavlan-9": "10.45.66.5" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::5", "kavlan-8": "2001:660:4406:694:2::5", "kavlan-9": "2001:660:4406:695:2::5" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:5", + "kavlan-11": "2001:660:4406:1a0:602:1:0:5", + "kavlan-12": "2001:660:4406:2a0:602:1:0:5", + "kavlan-13": "2001:660:4406:4a0:602:1:0:5", + "kavlan-14": "2001:660:4406:5a0:602:1:0:5", + "kavlan-16": "2001:660:4406:7a0:602:1:0:5", + "kavlan-17": "2001:660:4406:9a0:602:1:0:5", + "kavlan-18": "2001:660:4406:8a0:602:1:0:5", + "kavlan-2": "2001:660:4406:681:2:1:0:5", + "kavlan-20": "2001:660:4406:3a0:602:1:0:5", + "kavlan-21": "2001:660:4406:6a0:602:1:0:5", + "kavlan-3": "2001:660:4406:682:2:1:0:5", + "kavlan-4": "2001:660:4406:690:2:1:0:5", + "kavlan-5": "2001:660:4406:691:2:1:0:5", + "kavlan-6": "2001:660:4406:692:2:1:0:5", + "kavlan-7": "2001:660:4406:693:2:1:0:5", + "kavlan-8": "2001:660:4406:694:2:1:0:5", + "kavlan-9": "2001:660:4406:695:2:1:0:5" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.5", + "ip6": "2001:660:4406:600:2:1:0:5", + "kavlan": true, "mac": "24:6e:96:6a:d3:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-5-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/5", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json index f66d059aea8..7888a13dc80 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.6", "kavlan-8": "10.45.1.6", "kavlan-9": "10.45.65.6" + }, + "eth1": { + "kavlan-1": "192.168.194.6", + "kavlan-11": "10.7.241.106", + "kavlan-12": "10.11.241.106", + "kavlan-13": "10.15.241.106", + "kavlan-14": "10.19.241.106", + "kavlan-16": "10.27.241.106", + "kavlan-17": "10.31.241.106", + "kavlan-18": "10.35.241.106", + "kavlan-2": "192.168.210.6", + "kavlan-20": "10.43.241.106", + "kavlan-21": "10.47.241.106", + "kavlan-3": "192.168.226.6", + "kavlan-4": "10.44.2.6", + "kavlan-5": "10.44.66.6", + "kavlan-6": "10.44.130.6", + "kavlan-7": "10.44.194.6", + "kavlan-8": "10.45.2.6", + "kavlan-9": "10.45.66.6" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::6", "kavlan-8": "2001:660:4406:694:2::6", "kavlan-9": "2001:660:4406:695:2::6" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:6", + "kavlan-11": "2001:660:4406:1a0:602:1:0:6", + "kavlan-12": "2001:660:4406:2a0:602:1:0:6", + "kavlan-13": "2001:660:4406:4a0:602:1:0:6", + "kavlan-14": "2001:660:4406:5a0:602:1:0:6", + "kavlan-16": "2001:660:4406:7a0:602:1:0:6", + "kavlan-17": "2001:660:4406:9a0:602:1:0:6", + "kavlan-18": "2001:660:4406:8a0:602:1:0:6", + "kavlan-2": "2001:660:4406:681:2:1:0:6", + "kavlan-20": "2001:660:4406:3a0:602:1:0:6", + "kavlan-21": "2001:660:4406:6a0:602:1:0:6", + "kavlan-3": "2001:660:4406:682:2:1:0:6", + "kavlan-4": "2001:660:4406:690:2:1:0:6", + "kavlan-5": "2001:660:4406:691:2:1:0:6", + "kavlan-6": "2001:660:4406:692:2:1:0:6", + "kavlan-7": "2001:660:4406:693:2:1:0:6", + "kavlan-8": "2001:660:4406:694:2:1:0:6", + "kavlan-9": "2001:660:4406:695:2:1:0:6" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.6", + "ip6": "2001:660:4406:600:2:1:0:6", + "kavlan": true, "mac": "24:6e:96:6a:d6:b2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-6-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/6", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json index 56f855d5e97..d08c3c1005c 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.7", "kavlan-8": "10.45.1.7", "kavlan-9": "10.45.65.7" + }, + "eth1": { + "kavlan-1": "192.168.194.7", + "kavlan-11": "10.7.241.107", + "kavlan-12": "10.11.241.107", + "kavlan-13": "10.15.241.107", + "kavlan-14": "10.19.241.107", + "kavlan-16": "10.27.241.107", + "kavlan-17": "10.31.241.107", + "kavlan-18": "10.35.241.107", + "kavlan-2": "192.168.210.7", + "kavlan-20": "10.43.241.107", + "kavlan-21": "10.47.241.107", + "kavlan-3": "192.168.226.7", + "kavlan-4": "10.44.2.7", + "kavlan-5": "10.44.66.7", + "kavlan-6": "10.44.130.7", + "kavlan-7": "10.44.194.7", + "kavlan-8": "10.45.2.7", + "kavlan-9": "10.45.66.7" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::7", "kavlan-8": "2001:660:4406:694:2::7", "kavlan-9": "2001:660:4406:695:2::7" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:7", + "kavlan-11": "2001:660:4406:1a0:602:1:0:7", + "kavlan-12": "2001:660:4406:2a0:602:1:0:7", + "kavlan-13": "2001:660:4406:4a0:602:1:0:7", + "kavlan-14": "2001:660:4406:5a0:602:1:0:7", + "kavlan-16": "2001:660:4406:7a0:602:1:0:7", + "kavlan-17": "2001:660:4406:9a0:602:1:0:7", + "kavlan-18": "2001:660:4406:8a0:602:1:0:7", + "kavlan-2": "2001:660:4406:681:2:1:0:7", + "kavlan-20": "2001:660:4406:3a0:602:1:0:7", + "kavlan-21": "2001:660:4406:6a0:602:1:0:7", + "kavlan-3": "2001:660:4406:682:2:1:0:7", + "kavlan-4": "2001:660:4406:690:2:1:0:7", + "kavlan-5": "2001:660:4406:691:2:1:0:7", + "kavlan-6": "2001:660:4406:692:2:1:0:7", + "kavlan-7": "2001:660:4406:693:2:1:0:7", + "kavlan-8": "2001:660:4406:694:2:1:0:7", + "kavlan-9": "2001:660:4406:695:2:1:0:7" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.7", + "ip6": "2001:660:4406:600:2:1:0:7", + "kavlan": true, "mac": "24:6e:96:6a:4f:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-7-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/7", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json index 32add3efa28..58c530b1ada 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.8", "kavlan-8": "10.45.1.8", "kavlan-9": "10.45.65.8" + }, + "eth1": { + "kavlan-1": "192.168.194.8", + "kavlan-11": "10.7.241.108", + "kavlan-12": "10.11.241.108", + "kavlan-13": "10.15.241.108", + "kavlan-14": "10.19.241.108", + "kavlan-16": "10.27.241.108", + "kavlan-17": "10.31.241.108", + "kavlan-18": "10.35.241.108", + "kavlan-2": "192.168.210.8", + "kavlan-20": "10.43.241.108", + "kavlan-21": "10.47.241.108", + "kavlan-3": "192.168.226.8", + "kavlan-4": "10.44.2.8", + "kavlan-5": "10.44.66.8", + "kavlan-6": "10.44.130.8", + "kavlan-7": "10.44.194.8", + "kavlan-8": "10.45.2.8", + "kavlan-9": "10.45.66.8" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::8", "kavlan-8": "2001:660:4406:694:2::8", "kavlan-9": "2001:660:4406:695:2::8" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:8", + "kavlan-11": "2001:660:4406:1a0:602:1:0:8", + "kavlan-12": "2001:660:4406:2a0:602:1:0:8", + "kavlan-13": "2001:660:4406:4a0:602:1:0:8", + "kavlan-14": "2001:660:4406:5a0:602:1:0:8", + "kavlan-16": "2001:660:4406:7a0:602:1:0:8", + "kavlan-17": "2001:660:4406:9a0:602:1:0:8", + "kavlan-18": "2001:660:4406:8a0:602:1:0:8", + "kavlan-2": "2001:660:4406:681:2:1:0:8", + "kavlan-20": "2001:660:4406:3a0:602:1:0:8", + "kavlan-21": "2001:660:4406:6a0:602:1:0:8", + "kavlan-3": "2001:660:4406:682:2:1:0:8", + "kavlan-4": "2001:660:4406:690:2:1:0:8", + "kavlan-5": "2001:660:4406:691:2:1:0:8", + "kavlan-6": "2001:660:4406:692:2:1:0:8", + "kavlan-7": "2001:660:4406:693:2:1:0:8", + "kavlan-8": "2001:660:4406:694:2:1:0:8", + "kavlan-9": "2001:660:4406:695:2:1:0:8" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.8", + "ip6": "2001:660:4406:600:2:1:0:8", + "kavlan": true, "mac": "24:6e:96:6a:c9:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-8-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/8", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json index 1cc43eb8c96..09f8cdf95bb 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.9", "kavlan-8": "10.45.1.9", "kavlan-9": "10.45.65.9" + }, + "eth1": { + "kavlan-1": "192.168.194.9", + "kavlan-11": "10.7.241.109", + "kavlan-12": "10.11.241.109", + "kavlan-13": "10.15.241.109", + "kavlan-14": "10.19.241.109", + "kavlan-16": "10.27.241.109", + "kavlan-17": "10.31.241.109", + "kavlan-18": "10.35.241.109", + "kavlan-2": "192.168.210.9", + "kavlan-20": "10.43.241.109", + "kavlan-21": "10.47.241.109", + "kavlan-3": "192.168.226.9", + "kavlan-4": "10.44.2.9", + "kavlan-5": "10.44.66.9", + "kavlan-6": "10.44.130.9", + "kavlan-7": "10.44.194.9", + "kavlan-8": "10.45.2.9", + "kavlan-9": "10.45.66.9" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::9", "kavlan-8": "2001:660:4406:694:2::9", "kavlan-9": "2001:660:4406:695:2::9" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:9", + "kavlan-11": "2001:660:4406:1a0:602:1:0:9", + "kavlan-12": "2001:660:4406:2a0:602:1:0:9", + "kavlan-13": "2001:660:4406:4a0:602:1:0:9", + "kavlan-14": "2001:660:4406:5a0:602:1:0:9", + "kavlan-16": "2001:660:4406:7a0:602:1:0:9", + "kavlan-17": "2001:660:4406:9a0:602:1:0:9", + "kavlan-18": "2001:660:4406:8a0:602:1:0:9", + "kavlan-2": "2001:660:4406:681:2:1:0:9", + "kavlan-20": "2001:660:4406:3a0:602:1:0:9", + "kavlan-21": "2001:660:4406:6a0:602:1:0:9", + "kavlan-3": "2001:660:4406:682:2:1:0:9", + "kavlan-4": "2001:660:4406:690:2:1:0:9", + "kavlan-5": "2001:660:4406:691:2:1:0:9", + "kavlan-6": "2001:660:4406:692:2:1:0:9", + "kavlan-7": "2001:660:4406:693:2:1:0:9", + "kavlan-8": "2001:660:4406:694:2:1:0:9", + "kavlan-9": "2001:660:4406:695:2:1:0:9" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.9", + "ip6": "2001:660:4406:600:2:1:0:9", + "kavlan": true, "mac": "24:6e:96:6a:d7:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-9-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/9", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json b/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json index a1a2353ad02..f2983243a0e 100644 --- a/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json +++ b/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json @@ -20,100 +20,292 @@ { }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/1", + "uid": "ecotype-1" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/2", + "uid": "ecotype-2" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/3", + "uid": "ecotype-3" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/4", + "uid": "ecotype-4" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/5", + "uid": "ecotype-5" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/6", + "uid": "ecotype-6" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/7", + "uid": "ecotype-7" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/8", + "uid": "ecotype-8" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/9", + "uid": "ecotype-9" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/10", + "uid": "ecotype-10" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/11", + "uid": "ecotype-11" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/12", + "uid": "ecotype-12" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/13", + "uid": "ecotype-13" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/14", + "uid": "ecotype-14" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/15", + "uid": "ecotype-15" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/16", + "uid": "ecotype-16" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/17", + "uid": "ecotype-17" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/18", + "uid": "ecotype-18" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/19", + "uid": "ecotype-19" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/20", + "uid": "ecotype-20" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/21", + "uid": "ecotype-21" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/22", + "uid": "ecotype-22" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/23", + "uid": "ecotype-23" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/24", + "uid": "ecotype-24" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/25", + "uid": "ecotype-25" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/26", + "uid": "ecotype-26" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/27", + "uid": "ecotype-27" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/28", + "uid": "ecotype-28" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/29", + "uid": "ecotype-29" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/30", + "uid": "ecotype-30" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/31", + "uid": "ecotype-31" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/32", + "uid": "ecotype-32" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/33", + "uid": "ecotype-33" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/34", + "uid": "ecotype-34" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/35", + "uid": "ecotype-35" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/36", + "uid": "ecotype-36" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/37", + "uid": "ecotype-37" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/38", + "uid": "ecotype-38" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/39", + "uid": "ecotype-39" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/40", + "uid": "ecotype-40" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/41", + "uid": "ecotype-41" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/42", + "uid": "ecotype-42" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/43", + "uid": "ecotype-43" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/44", + "uid": "ecotype-44" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/45", + "uid": "ecotype-45" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/46", + "uid": "ecotype-46" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/47", + "uid": "ecotype-47" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/48", + "uid": "ecotype-48" }, { "kind": "channel", diff --git a/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml b/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml index dedfe3b2464..2649f1ffd48 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml @@ -28,8 +28,8 @@ nodes: mountable: true eth1: mounted: false - enabled: false - mountable: false + enabled: true + mountable: true eth2: mounted: false enabled: false diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml index a681f6d37d7..0da08afc7f6 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml @@ -69,6 +69,7 @@ ecotype-10: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml index 6f38b08e0ce..6998bcf509e 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml @@ -69,6 +69,7 @@ ecotype-11: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml index 2a4068f895d..d21844ad5b0 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml @@ -69,6 +69,7 @@ ecotype-12: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml index a7ad0c13c4d..c0b7f5085cc 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml @@ -69,6 +69,7 @@ ecotype-13: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml index c2e75c1a332..73bcbaa3db4 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml @@ -69,6 +69,7 @@ ecotype-14: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml index fabeb8b5d69..3143d72e891 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml @@ -69,6 +69,7 @@ ecotype-15: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml index fc7b6e12741..24f369f7b9a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml @@ -69,6 +69,7 @@ ecotype-16: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml index 66e62b59017..bf632d8605d 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml @@ -69,6 +69,7 @@ ecotype-17: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml index fce9f08c63f..4a28e35f068 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml @@ -69,6 +69,7 @@ ecotype-18: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml index 68b9f44b80b..1964f5e06ad 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml @@ -69,6 +69,7 @@ ecotype-19: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml index bb5b636cdef..be047fdc5b7 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml @@ -69,6 +69,7 @@ ecotype-2: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml index 07c39b72020..9a8300619b6 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml @@ -69,6 +69,7 @@ ecotype-20: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml index 0f331ee73f7..53532cc732e 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml @@ -69,6 +69,7 @@ ecotype-21: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml index 42ed17a8a7f..c809a6a6c2b 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml @@ -69,6 +69,7 @@ ecotype-22: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml index 45beab8e454..86ddd4dae76 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml @@ -69,6 +69,7 @@ ecotype-23: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml index e3a0257803f..79b439bfc96 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml @@ -69,6 +69,7 @@ ecotype-24: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml index 5e61db19718..1bc11730d6c 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml @@ -69,6 +69,7 @@ ecotype-25: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml index 790aeef309d..c8dc9d7eb17 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml @@ -69,6 +69,7 @@ ecotype-26: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml index 3dd4b60dd17..6ce521ba29e 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml @@ -69,6 +69,7 @@ ecotype-27: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml index abe54787b97..e6e4b55f894 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml @@ -69,6 +69,7 @@ ecotype-28: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml index 4a850f0ae6a..bfb6915ae8f 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml @@ -69,6 +69,7 @@ ecotype-29: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml index 3750cc5fc67..2c5484c19ee 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml @@ -69,6 +69,7 @@ ecotype-3: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml index 639c6bfa9f7..650529e597d 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml @@ -69,6 +69,7 @@ ecotype-30: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml index 0cc48946431..9ec98a779f4 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml @@ -69,6 +69,7 @@ ecotype-31: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml index 21178a4326c..47947476aa2 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml @@ -69,6 +69,7 @@ ecotype-32: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml index 1075fc1f4b5..a9e45d66492 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml @@ -69,6 +69,7 @@ ecotype-33: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml index da3ba5e72c5..7453939a65f 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml @@ -69,6 +69,7 @@ ecotype-34: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml index 25bc53cef46..fe8630c1655 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml @@ -69,6 +69,7 @@ ecotype-35: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml index 6129e527072..6ca0af04403 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml @@ -69,6 +69,7 @@ ecotype-36: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml index 0bc3db385c0..267fb2a255f 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml @@ -69,6 +69,7 @@ ecotype-37: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml index 13810c7e2ff..a3a42c3cdd0 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml @@ -69,6 +69,7 @@ ecotype-38: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml index 6e7a118130d..201a7402e22 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml @@ -69,6 +69,7 @@ ecotype-39: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml index 603b5fc1e5d..c389b9f77be 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml @@ -69,6 +69,7 @@ ecotype-4: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml index f7058bd4647..d24af112913 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml @@ -69,6 +69,7 @@ ecotype-40: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml index 2a226090084..8d148848b4b 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml @@ -69,6 +69,7 @@ ecotype-41: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml index b01271eb916..7addc34ff38 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml @@ -69,6 +69,7 @@ ecotype-42: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml index e175a61f59b..067e24d2378 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml @@ -69,6 +69,7 @@ ecotype-43: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml index be71dced604..11da2b00ff3 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml @@ -69,6 +69,7 @@ ecotype-44: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml index f46ab0fe9d9..2eb933b5cb5 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml @@ -69,6 +69,7 @@ ecotype-45: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml index d2ff367f3be..d1e63b3b5ed 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml @@ -69,6 +69,7 @@ ecotype-46: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml index 72503c67ec0..04324a857f2 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml @@ -45,7 +45,7 @@ ecotype-47: technology: dram network_adapters: bmc: - ip: 172.17.193.47 + ip: 0.0.0.0 mac: 50:9a:4c:a8:8d:9c management: true eth0: diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml index f4f311a0d86..54632ee6074 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml @@ -69,6 +69,7 @@ ecotype-48: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml index 54b790496d3..44329880518 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml @@ -69,6 +69,7 @@ ecotype-5: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml index 1a326cb50a4..822d8f6f084 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml @@ -69,6 +69,7 @@ ecotype-6: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml index 9f2b8a4b506..5a19bbc0b62 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml @@ -69,6 +69,7 @@ ecotype-7: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml index 1a8f675a85a..897ca0de319 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml @@ -69,6 +69,7 @@ ecotype-8: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml index d9229785018..bac9ecfc5fa 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml @@ -69,6 +69,7 @@ ecotype-9: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml b/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml index aa850c051ea..067281d2a5d 100644 --- a/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml +++ b/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml @@ -64,54 +64,54 @@ ecotype-prod2: kind: node rate: 10000000000 ports: - 1: - 2: - 3: - 4: - 5: - 6: - 8: - 7: - 9: - 10: - 11: - 12: - 13: - 14: - 15: - 16: - 17: - 18: - 19: - 20: - 21: - 22: - 23: - 24: - 25: - 26: - 27: - 28: - 29: - 30: - 31: - 32: - 33: - 34: - 35: - 36: - 37: - 38: - 39: - 40: - 41: - 42: - 43: - 44: - 45: - 46: - 47: - 48: + 1: ecotype-1-eth1 + 2: ecotype-2-eth1 + 3: ecotype-3-eth1 + 4: ecotype-4-eth1 + 5: ecotype-5-eth1 + 6: ecotype-6-eth1 + 8: ecotype-8-eth1 + 7: ecotype-7-eth1 + 9: ecotype-9-eth1 + 10: ecotype-10-eth1 + 11: ecotype-11-eth1 + 12: ecotype-12-eth1 + 13: ecotype-13-eth1 + 14: ecotype-14-eth1 + 15: ecotype-15-eth1 + 16: ecotype-16-eth1 + 17: ecotype-17-eth1 + 18: ecotype-18-eth1 + 19: ecotype-19-eth1 + 20: ecotype-20-eth1 + 21: ecotype-21-eth1 + 22: ecotype-22-eth1 + 23: ecotype-23-eth1 + 24: ecotype-24-eth1 + 25: ecotype-25-eth1 + 26: ecotype-26-eth1 + 27: ecotype-27-eth1 + 28: ecotype-28-eth1 + 29: ecotype-29-eth1 + 30: ecotype-30-eth1 + 31: ecotype-31-eth1 + 32: ecotype-32-eth1 + 33: ecotype-33-eth1 + 34: ecotype-34-eth1 + 35: ecotype-35-eth1 + 36: ecotype-36-eth1 + 37: ecotype-37-eth1 + 38: ecotype-38-eth1 + 39: ecotype-39-eth1 + 40: ecotype-40-eth1 + 41: ecotype-41-eth1 + 42: ecotype-42-eth1 + 43: ecotype-43-eth1 + 44: ecotype-44-eth1 + 45: ecotype-45-eth1 + 46: ecotype-46-eth1 + 47: ecotype-47-eth1 + 48: ecotype-48-eth1 49: uid: Port-channel 1 snmp_pattern: "fortyGigE %LINECARD%/%PORT%" diff --git a/lib/refrepo/valid/data/homogeneity.yaml.erb b/lib/refrepo/valid/data/homogeneity.yaml.erb index 000d320fe64..8f09716ff19 100644 --- a/lib/refrepo/valid/data/homogeneity.yaml.erb +++ b/lib/refrepo/valid/data/homogeneity.yaml.erb @@ -288,6 +288,12 @@ nantes: - ~network_adapters.eth0.firmware_version - ~network_adapters.eth1.firmware_version - ~storage_devices.pci-0000:00:1f.2-ata-1.firmware_version + ecotype-2: + - +network_adapters.eth1.rate + ecotype-47: + - -network_adapters.eth1.rate + ecotype-48: + - +network_adapters.eth1.rate rennes: paradoxe-[2-3]: - ~storage_devices.pci-0000:47:00.0-scsi-0:2:1:0.firmware_version -- GitLab