diff --git a/data/grid5000/accesses/refrepo.json b/data/grid5000/accesses/refrepo.json index 0b3b588d7f5dd1498a12afa7bc5ef3e563704512..f4d6bec7889bbaaef00640d779b362a46c531f9b 100644 --- a/data/grid5000/accesses/refrepo.json +++ b/data/grid5000/accesses/refrepo.json @@ -87119,18 +87119,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.1", + "ip6": "2001:660:4406:600:2:1:0:1", + "kavlan": true, "mac": "24:6e:96:6a:46:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-1-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/1", "vendor": "Intel" }, { @@ -87294,18 +87299,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.10", + "ip6": "2001:660:4406:600:2:1:0:a", + "kavlan": true, "mac": "24:6e:96:6a:d1:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-10-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/10", "vendor": "Intel" }, { @@ -87469,18 +87480,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.11", + "ip6": "2001:660:4406:600:2:1:0:b", + "kavlan": true, "mac": "24:6e:96:6a:4f:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-11-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/11", "vendor": "Intel" }, { @@ -87644,18 +87661,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.12", + "ip6": "2001:660:4406:600:2:1:0:c", + "kavlan": true, "mac": "24:6e:96:6a:52:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-12-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/12", "vendor": "Intel" }, { @@ -87819,18 +87842,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.13", + "ip6": "2001:660:4406:600:2:1:0:d", + "kavlan": true, "mac": "24:6e:96:6a:49:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-13-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/13", "vendor": "Intel" }, { @@ -87994,18 +88023,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.14", + "ip6": "2001:660:4406:600:2:1:0:e", + "kavlan": true, "mac": "24:6e:96:6a:46:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-14-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/14", "vendor": "Intel" }, { @@ -88169,18 +88204,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.15", + "ip6": "2001:660:4406:600:2:1:0:f", + "kavlan": true, "mac": "24:6e:96:6a:46:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-15-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/15", "vendor": "Intel" }, { @@ -88344,18 +88385,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.16", + "ip6": "2001:660:4406:600:2:1:0:10", + "kavlan": true, "mac": "24:6e:96:6a:46:c2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-16-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/16", "vendor": "Intel" }, { @@ -88519,18 +88566,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.17", + "ip6": "2001:660:4406:600:2:1:0:11", + "kavlan": true, "mac": "24:6e:96:6a:47:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-17-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/17", "vendor": "Intel" }, { @@ -88694,18 +88747,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.18", + "ip6": "2001:660:4406:600:2:1:0:12", + "kavlan": true, "mac": "24:6e:96:6a:5a:5a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-18-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/18", "vendor": "Intel" }, { @@ -88869,18 +88928,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.19", + "ip6": "2001:660:4406:600:2:1:0:13", + "kavlan": true, "mac": "24:6e:96:6a:59:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-19-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/19", "vendor": "Intel" }, { @@ -89044,18 +89109,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.2", + "ip6": "2001:660:4406:600:2:1:0:2", + "kavlan": true, "mac": "24:6e:96:6a:d0:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-2-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/2", "vendor": "Intel" }, { @@ -89219,18 +89290,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.20", + "ip6": "2001:660:4406:600:2:1:0:14", + "kavlan": true, "mac": "24:6e:96:6a:50:12", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-20-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/20", "vendor": "Intel" }, { @@ -89394,18 +89471,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.21", + "ip6": "2001:660:4406:600:2:1:0:15", + "kavlan": true, "mac": "24:6e:96:6a:c9:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-21-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/21", "vendor": "Intel" }, { @@ -89569,18 +89652,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.22", + "ip6": "2001:660:4406:600:2:1:0:16", + "kavlan": true, "mac": "24:6e:96:6a:d3:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-22-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/22", "vendor": "Intel" }, { @@ -89744,18 +89833,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.23", + "ip6": "2001:660:4406:600:2:1:0:17", + "kavlan": true, "mac": "24:6e:96:6a:4e:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-23-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/23", "vendor": "Intel" }, { @@ -89919,18 +90014,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.24", + "ip6": "2001:660:4406:600:2:1:0:18", + "kavlan": true, "mac": "24:6e:96:6a:cf:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-24-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/24", "vendor": "Intel" }, { @@ -90094,18 +90195,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.25", + "ip6": "2001:660:4406:600:2:1:0:19", + "kavlan": true, "mac": "24:6e:96:6a:48:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-25-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/25", "vendor": "Intel" }, { @@ -90269,18 +90376,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.26", + "ip6": "2001:660:4406:600:2:1:0:1a", + "kavlan": true, "mac": "24:6e:96:6a:4e:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-26-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/26", "vendor": "Intel" }, { @@ -90444,18 +90557,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.27", + "ip6": "2001:660:4406:600:2:1:0:1b", + "kavlan": true, "mac": "24:6e:96:6a:d9:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-27-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/27", "vendor": "Intel" }, { @@ -90619,18 +90738,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.28", + "ip6": "2001:660:4406:600:2:1:0:1c", + "kavlan": true, "mac": "24:6e:96:6a:ca:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-28-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/28", "vendor": "Intel" }, { @@ -90794,18 +90919,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.29", + "ip6": "2001:660:4406:600:2:1:0:1d", + "kavlan": true, "mac": "24:6e:96:6a:d8:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-29-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/29", "vendor": "Intel" }, { @@ -90969,18 +91100,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.3", + "ip6": "2001:660:4406:600:2:1:0:3", + "kavlan": true, "mac": "24:6e:96:6a:d7:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-3-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/3", "vendor": "Intel" }, { @@ -91144,18 +91281,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.30", + "ip6": "2001:660:4406:600:2:1:0:1e", + "kavlan": true, "mac": "24:6e:96:6a:51:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-30-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/30", "vendor": "Intel" }, { @@ -91319,18 +91462,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.31", + "ip6": "2001:660:4406:600:2:1:0:1f", + "kavlan": true, "mac": "24:6e:96:6a:d8:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-31-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/31", "vendor": "Intel" }, { @@ -91494,18 +91643,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.32", + "ip6": "2001:660:4406:600:2:1:0:20", + "kavlan": true, "mac": "24:6e:96:6a:d6:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-32-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/32", "vendor": "Intel" }, { @@ -91669,18 +91824,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.33", + "ip6": "2001:660:4406:600:2:1:0:21", + "kavlan": true, "mac": "24:6e:96:6a:4e:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-33-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/33", "vendor": "Intel" }, { @@ -91844,18 +92005,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.34", + "ip6": "2001:660:4406:600:2:1:0:22", + "kavlan": true, "mac": "24:6e:96:6a:c9:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-34-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/34", "vendor": "Intel" }, { @@ -92019,18 +92186,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.35", + "ip6": "2001:660:4406:600:2:1:0:23", + "kavlan": true, "mac": "24:6e:96:6a:d1:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-35-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/35", "vendor": "Intel" }, { @@ -92194,18 +92367,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.36", + "ip6": "2001:660:4406:600:2:1:0:24", + "kavlan": true, "mac": "24:6e:96:6a:56:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-36-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/36", "vendor": "Intel" }, { @@ -92369,18 +92548,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.37", + "ip6": "2001:660:4406:600:2:1:0:25", + "kavlan": true, "mac": "24:6e:96:6a:cc:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-37-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/37", "vendor": "Intel" }, { @@ -92544,18 +92729,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.38", + "ip6": "2001:660:4406:600:2:1:0:26", + "kavlan": true, "mac": "24:6e:96:6a:d7:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-38-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/38", "vendor": "Intel" }, { @@ -92719,18 +92910,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.39", + "ip6": "2001:660:4406:600:2:1:0:27", + "kavlan": true, "mac": "24:6e:96:6a:d1:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-39-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/39", "vendor": "Intel" }, { @@ -92894,18 +93091,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.4", + "ip6": "2001:660:4406:600:2:1:0:4", + "kavlan": true, "mac": "24:6e:96:6a:d7:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-4-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/4", "vendor": "Intel" }, { @@ -93069,18 +93272,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.40", + "ip6": "2001:660:4406:600:2:1:0:28", + "kavlan": true, "mac": "24:6e:96:6a:4f:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-40-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/40", "vendor": "Intel" }, { @@ -93244,18 +93453,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.41", + "ip6": "2001:660:4406:600:2:1:0:29", + "kavlan": true, "mac": "24:6e:96:6a:49:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-41-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/41", "vendor": "Intel" }, { @@ -93419,18 +93634,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.42", + "ip6": "2001:660:4406:600:2:1:0:2a", + "kavlan": true, "mac": "24:6e:96:6a:4c:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-42-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/42", "vendor": "Intel" }, { @@ -93594,18 +93815,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.43", + "ip6": "2001:660:4406:600:2:1:0:2b", + "kavlan": true, "mac": "24:6e:96:6a:d0:82", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-43-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/43", "vendor": "Intel" }, { @@ -93769,18 +93996,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.44", + "ip6": "2001:660:4406:600:2:1:0:2c", + "kavlan": true, "mac": "24:6e:96:6a:63:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-44-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/44", "vendor": "Intel" }, { @@ -93944,18 +94177,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.45", + "ip6": "2001:660:4406:600:2:1:0:2d", + "kavlan": true, "mac": "24:6e:96:6a:47:42", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-45-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/45", "vendor": "Intel" }, { @@ -94119,18 +94358,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.46", + "ip6": "2001:660:4406:600:2:1:0:2e", + "kavlan": true, "mac": "24:6e:96:6a:c9:aa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-46-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/46", "vendor": "Intel" }, { @@ -94294,18 +94539,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.47", + "ip6": "2001:660:4406:600:2:1:0:2f", + "kavlan": true, "mac": "24:6e:96:6a:d1:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-47-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/47", "vendor": "Intel" }, { @@ -94346,7 +94596,7 @@ "device": "bmc", "enabled": true, "interface": "Ethernet", - "ip": "172.17.193.47", + "ip": "0.0.0.0", "kavlan": false, "mac": "50:9a:4c:a8:8d:9c", "management": true, @@ -94469,18 +94719,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.48", + "ip6": "2001:660:4406:600:2:1:0:30", + "kavlan": true, "mac": "24:6e:96:6a:cf:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-48-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/48", "vendor": "Intel" }, { @@ -94644,18 +94900,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.5", + "ip6": "2001:660:4406:600:2:1:0:5", + "kavlan": true, "mac": "24:6e:96:6a:d3:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-5-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/5", "vendor": "Intel" }, { @@ -94819,18 +95081,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.6", + "ip6": "2001:660:4406:600:2:1:0:6", + "kavlan": true, "mac": "24:6e:96:6a:d6:b2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-6-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/6", "vendor": "Intel" }, { @@ -94994,18 +95262,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.7", + "ip6": "2001:660:4406:600:2:1:0:7", + "kavlan": true, "mac": "24:6e:96:6a:4f:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-7-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/7", "vendor": "Intel" }, { @@ -95169,18 +95443,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.8", + "ip6": "2001:660:4406:600:2:1:0:8", + "kavlan": true, "mac": "24:6e:96:6a:c9:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-8-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/8", "vendor": "Intel" }, { @@ -95344,18 +95624,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.9", + "ip6": "2001:660:4406:600:2:1:0:9", + "kavlan": true, "mac": "24:6e:96:6a:d7:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-9-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/9", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json b/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json index 1fd2951a825a6d4793f5c235646660ddcce528df..b85893bee7144ed02914199aee6f0aab796d3917 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/ecotype.json @@ -441,6 +441,94 @@ "source": { "protocol": "network_equipment" } + }, + { + "description": "Input byte counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_bytes_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output byte counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_bytes_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input packet counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output packet counter for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of discarded packets for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_discard_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of discarded packets for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_discard_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Input counter of packet errors for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifacein_packets_error_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } + }, + { + "description": "Output counter of packet errors for the network device port", + "labels": { + "interface": "eth1" + }, + "name": "network_ifaceout_packets_error_total", + "period": 1000, + "source": { + "protocol": "network_equipment" + } } ], "model": "Dell PowerEdge R630", diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json index ce0e85fe3fc01e42135f4f5ddcc7d2ef2ed1da09..9a80223e73db55f81ac13799d842f6bf3bc73949 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-1.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.1", "kavlan-8": "10.45.1.1", "kavlan-9": "10.45.65.1" + }, + "eth1": { + "kavlan-1": "192.168.194.1", + "kavlan-11": "10.7.241.101", + "kavlan-12": "10.11.241.101", + "kavlan-13": "10.15.241.101", + "kavlan-14": "10.19.241.101", + "kavlan-16": "10.27.241.101", + "kavlan-17": "10.31.241.101", + "kavlan-18": "10.35.241.101", + "kavlan-2": "192.168.210.1", + "kavlan-20": "10.43.241.101", + "kavlan-21": "10.47.241.101", + "kavlan-3": "192.168.226.1", + "kavlan-4": "10.44.2.1", + "kavlan-5": "10.44.66.1", + "kavlan-6": "10.44.130.1", + "kavlan-7": "10.44.194.1", + "kavlan-8": "10.45.2.1", + "kavlan-9": "10.45.66.1" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1", "kavlan-8": "2001:660:4406:694:2::1", "kavlan-9": "2001:660:4406:695:2::1" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1", + "kavlan-2": "2001:660:4406:681:2:1:0:1", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1", + "kavlan-3": "2001:660:4406:682:2:1:0:1", + "kavlan-4": "2001:660:4406:690:2:1:0:1", + "kavlan-5": "2001:660:4406:691:2:1:0:1", + "kavlan-6": "2001:660:4406:692:2:1:0:1", + "kavlan-7": "2001:660:4406:693:2:1:0:1", + "kavlan-8": "2001:660:4406:694:2:1:0:1", + "kavlan-9": "2001:660:4406:695:2:1:0:1" } }, "main_memory": { @@ -142,18 +182,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.1", + "ip6": "2001:660:4406:600:2:1:0:1", + "kavlan": true, "mac": "24:6e:96:6a:46:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-1-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/1", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json index a0efbe0dea60bce0b4df934cf5ef5cb0491445f2..21ac75fb54a1b913b75cf1fece9f3a190cb3091f 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.10", "kavlan-8": "10.45.1.10", "kavlan-9": "10.45.65.10" + }, + "eth1": { + "kavlan-1": "192.168.194.10", + "kavlan-11": "10.7.241.110", + "kavlan-12": "10.11.241.110", + "kavlan-13": "10.15.241.110", + "kavlan-14": "10.19.241.110", + "kavlan-16": "10.27.241.110", + "kavlan-17": "10.31.241.110", + "kavlan-18": "10.35.241.110", + "kavlan-2": "192.168.210.10", + "kavlan-20": "10.43.241.110", + "kavlan-21": "10.47.241.110", + "kavlan-3": "192.168.226.10", + "kavlan-4": "10.44.2.10", + "kavlan-5": "10.44.66.10", + "kavlan-6": "10.44.130.10", + "kavlan-7": "10.44.194.10", + "kavlan-8": "10.45.2.10", + "kavlan-9": "10.45.66.10" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::a", "kavlan-8": "2001:660:4406:694:2::a", "kavlan-9": "2001:660:4406:695:2::a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:a", + "kavlan-2": "2001:660:4406:681:2:1:0:a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:a", + "kavlan-3": "2001:660:4406:682:2:1:0:a", + "kavlan-4": "2001:660:4406:690:2:1:0:a", + "kavlan-5": "2001:660:4406:691:2:1:0:a", + "kavlan-6": "2001:660:4406:692:2:1:0:a", + "kavlan-7": "2001:660:4406:693:2:1:0:a", + "kavlan-8": "2001:660:4406:694:2:1:0:a", + "kavlan-9": "2001:660:4406:695:2:1:0:a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.10", + "ip6": "2001:660:4406:600:2:1:0:a", + "kavlan": true, "mac": "24:6e:96:6a:d1:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-10-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/10", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json index 114b0466f2ae7e3e9d83863451d34602544e702e..3c48b2482a49a7718c4304919bfc3c41700fa274 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.11", "kavlan-8": "10.45.1.11", "kavlan-9": "10.45.65.11" + }, + "eth1": { + "kavlan-1": "192.168.194.11", + "kavlan-11": "10.7.241.111", + "kavlan-12": "10.11.241.111", + "kavlan-13": "10.15.241.111", + "kavlan-14": "10.19.241.111", + "kavlan-16": "10.27.241.111", + "kavlan-17": "10.31.241.111", + "kavlan-18": "10.35.241.111", + "kavlan-2": "192.168.210.11", + "kavlan-20": "10.43.241.111", + "kavlan-21": "10.47.241.111", + "kavlan-3": "192.168.226.11", + "kavlan-4": "10.44.2.11", + "kavlan-5": "10.44.66.11", + "kavlan-6": "10.44.130.11", + "kavlan-7": "10.44.194.11", + "kavlan-8": "10.45.2.11", + "kavlan-9": "10.45.66.11" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::b", "kavlan-8": "2001:660:4406:694:2::b", "kavlan-9": "2001:660:4406:695:2::b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:b", + "kavlan-2": "2001:660:4406:681:2:1:0:b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:b", + "kavlan-3": "2001:660:4406:682:2:1:0:b", + "kavlan-4": "2001:660:4406:690:2:1:0:b", + "kavlan-5": "2001:660:4406:691:2:1:0:b", + "kavlan-6": "2001:660:4406:692:2:1:0:b", + "kavlan-7": "2001:660:4406:693:2:1:0:b", + "kavlan-8": "2001:660:4406:694:2:1:0:b", + "kavlan-9": "2001:660:4406:695:2:1:0:b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.11", + "ip6": "2001:660:4406:600:2:1:0:b", + "kavlan": true, "mac": "24:6e:96:6a:4f:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-11-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/11", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json index 446618e9c09017d86fc8fb720e28791147c79e5d..5e650a0ea8226a6000644fc2f6a3ed789da49ad0 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.12", "kavlan-8": "10.45.1.12", "kavlan-9": "10.45.65.12" + }, + "eth1": { + "kavlan-1": "192.168.194.12", + "kavlan-11": "10.7.241.112", + "kavlan-12": "10.11.241.112", + "kavlan-13": "10.15.241.112", + "kavlan-14": "10.19.241.112", + "kavlan-16": "10.27.241.112", + "kavlan-17": "10.31.241.112", + "kavlan-18": "10.35.241.112", + "kavlan-2": "192.168.210.12", + "kavlan-20": "10.43.241.112", + "kavlan-21": "10.47.241.112", + "kavlan-3": "192.168.226.12", + "kavlan-4": "10.44.2.12", + "kavlan-5": "10.44.66.12", + "kavlan-6": "10.44.130.12", + "kavlan-7": "10.44.194.12", + "kavlan-8": "10.45.2.12", + "kavlan-9": "10.45.66.12" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::c", "kavlan-8": "2001:660:4406:694:2::c", "kavlan-9": "2001:660:4406:695:2::c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:c", + "kavlan-2": "2001:660:4406:681:2:1:0:c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:c", + "kavlan-3": "2001:660:4406:682:2:1:0:c", + "kavlan-4": "2001:660:4406:690:2:1:0:c", + "kavlan-5": "2001:660:4406:691:2:1:0:c", + "kavlan-6": "2001:660:4406:692:2:1:0:c", + "kavlan-7": "2001:660:4406:693:2:1:0:c", + "kavlan-8": "2001:660:4406:694:2:1:0:c", + "kavlan-9": "2001:660:4406:695:2:1:0:c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.12", + "ip6": "2001:660:4406:600:2:1:0:c", + "kavlan": true, "mac": "24:6e:96:6a:52:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-12-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/12", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json index 2703c63b750cee57c709812f7e6ab761415dfcc9..5516346fb0c4c24ff995e02e364c3a07305387b6 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.13", "kavlan-8": "10.45.1.13", "kavlan-9": "10.45.65.13" + }, + "eth1": { + "kavlan-1": "192.168.194.13", + "kavlan-11": "10.7.241.113", + "kavlan-12": "10.11.241.113", + "kavlan-13": "10.15.241.113", + "kavlan-14": "10.19.241.113", + "kavlan-16": "10.27.241.113", + "kavlan-17": "10.31.241.113", + "kavlan-18": "10.35.241.113", + "kavlan-2": "192.168.210.13", + "kavlan-20": "10.43.241.113", + "kavlan-21": "10.47.241.113", + "kavlan-3": "192.168.226.13", + "kavlan-4": "10.44.2.13", + "kavlan-5": "10.44.66.13", + "kavlan-6": "10.44.130.13", + "kavlan-7": "10.44.194.13", + "kavlan-8": "10.45.2.13", + "kavlan-9": "10.45.66.13" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::d", "kavlan-8": "2001:660:4406:694:2::d", "kavlan-9": "2001:660:4406:695:2::d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:d", + "kavlan-2": "2001:660:4406:681:2:1:0:d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:d", + "kavlan-3": "2001:660:4406:682:2:1:0:d", + "kavlan-4": "2001:660:4406:690:2:1:0:d", + "kavlan-5": "2001:660:4406:691:2:1:0:d", + "kavlan-6": "2001:660:4406:692:2:1:0:d", + "kavlan-7": "2001:660:4406:693:2:1:0:d", + "kavlan-8": "2001:660:4406:694:2:1:0:d", + "kavlan-9": "2001:660:4406:695:2:1:0:d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.13", + "ip6": "2001:660:4406:600:2:1:0:d", + "kavlan": true, "mac": "24:6e:96:6a:49:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-13-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/13", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json index 9103883acf63d32351726c424d0b4bee43d97057..a813e287ce2a1dd6acaa2273dbefc7c47a98a8ae 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.14", "kavlan-8": "10.45.1.14", "kavlan-9": "10.45.65.14" + }, + "eth1": { + "kavlan-1": "192.168.194.14", + "kavlan-11": "10.7.241.114", + "kavlan-12": "10.11.241.114", + "kavlan-13": "10.15.241.114", + "kavlan-14": "10.19.241.114", + "kavlan-16": "10.27.241.114", + "kavlan-17": "10.31.241.114", + "kavlan-18": "10.35.241.114", + "kavlan-2": "192.168.210.14", + "kavlan-20": "10.43.241.114", + "kavlan-21": "10.47.241.114", + "kavlan-3": "192.168.226.14", + "kavlan-4": "10.44.2.14", + "kavlan-5": "10.44.66.14", + "kavlan-6": "10.44.130.14", + "kavlan-7": "10.44.194.14", + "kavlan-8": "10.45.2.14", + "kavlan-9": "10.45.66.14" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::e", "kavlan-8": "2001:660:4406:694:2::e", "kavlan-9": "2001:660:4406:695:2::e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:e", + "kavlan-2": "2001:660:4406:681:2:1:0:e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:e", + "kavlan-3": "2001:660:4406:682:2:1:0:e", + "kavlan-4": "2001:660:4406:690:2:1:0:e", + "kavlan-5": "2001:660:4406:691:2:1:0:e", + "kavlan-6": "2001:660:4406:692:2:1:0:e", + "kavlan-7": "2001:660:4406:693:2:1:0:e", + "kavlan-8": "2001:660:4406:694:2:1:0:e", + "kavlan-9": "2001:660:4406:695:2:1:0:e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.14", + "ip6": "2001:660:4406:600:2:1:0:e", + "kavlan": true, "mac": "24:6e:96:6a:46:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-14-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/14", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json index 708c6fe3d959b042f8eab6e6a4e445d7337da392..83f9278646978cda4ce7b5996d7dab9cef0d71f3 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.15", "kavlan-8": "10.45.1.15", "kavlan-9": "10.45.65.15" + }, + "eth1": { + "kavlan-1": "192.168.194.15", + "kavlan-11": "10.7.241.115", + "kavlan-12": "10.11.241.115", + "kavlan-13": "10.15.241.115", + "kavlan-14": "10.19.241.115", + "kavlan-16": "10.27.241.115", + "kavlan-17": "10.31.241.115", + "kavlan-18": "10.35.241.115", + "kavlan-2": "192.168.210.15", + "kavlan-20": "10.43.241.115", + "kavlan-21": "10.47.241.115", + "kavlan-3": "192.168.226.15", + "kavlan-4": "10.44.2.15", + "kavlan-5": "10.44.66.15", + "kavlan-6": "10.44.130.15", + "kavlan-7": "10.44.194.15", + "kavlan-8": "10.45.2.15", + "kavlan-9": "10.45.66.15" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::f", "kavlan-8": "2001:660:4406:694:2::f", "kavlan-9": "2001:660:4406:695:2::f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:f", + "kavlan-2": "2001:660:4406:681:2:1:0:f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:f", + "kavlan-3": "2001:660:4406:682:2:1:0:f", + "kavlan-4": "2001:660:4406:690:2:1:0:f", + "kavlan-5": "2001:660:4406:691:2:1:0:f", + "kavlan-6": "2001:660:4406:692:2:1:0:f", + "kavlan-7": "2001:660:4406:693:2:1:0:f", + "kavlan-8": "2001:660:4406:694:2:1:0:f", + "kavlan-9": "2001:660:4406:695:2:1:0:f" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.15", + "ip6": "2001:660:4406:600:2:1:0:f", + "kavlan": true, "mac": "24:6e:96:6a:46:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-15-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/15", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json index 03e8b0251a70209ab9c2dd5bb68a15be982a0c2e..d0b896ff6ac004f470d170b59170414eb7d73a13 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.16", "kavlan-8": "10.45.1.16", "kavlan-9": "10.45.65.16" + }, + "eth1": { + "kavlan-1": "192.168.194.16", + "kavlan-11": "10.7.241.116", + "kavlan-12": "10.11.241.116", + "kavlan-13": "10.15.241.116", + "kavlan-14": "10.19.241.116", + "kavlan-16": "10.27.241.116", + "kavlan-17": "10.31.241.116", + "kavlan-18": "10.35.241.116", + "kavlan-2": "192.168.210.16", + "kavlan-20": "10.43.241.116", + "kavlan-21": "10.47.241.116", + "kavlan-3": "192.168.226.16", + "kavlan-4": "10.44.2.16", + "kavlan-5": "10.44.66.16", + "kavlan-6": "10.44.130.16", + "kavlan-7": "10.44.194.16", + "kavlan-8": "10.45.2.16", + "kavlan-9": "10.45.66.16" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::10", "kavlan-8": "2001:660:4406:694:2::10", "kavlan-9": "2001:660:4406:695:2::10" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:10", + "kavlan-11": "2001:660:4406:1a0:602:1:0:10", + "kavlan-12": "2001:660:4406:2a0:602:1:0:10", + "kavlan-13": "2001:660:4406:4a0:602:1:0:10", + "kavlan-14": "2001:660:4406:5a0:602:1:0:10", + "kavlan-16": "2001:660:4406:7a0:602:1:0:10", + "kavlan-17": "2001:660:4406:9a0:602:1:0:10", + "kavlan-18": "2001:660:4406:8a0:602:1:0:10", + "kavlan-2": "2001:660:4406:681:2:1:0:10", + "kavlan-20": "2001:660:4406:3a0:602:1:0:10", + "kavlan-21": "2001:660:4406:6a0:602:1:0:10", + "kavlan-3": "2001:660:4406:682:2:1:0:10", + "kavlan-4": "2001:660:4406:690:2:1:0:10", + "kavlan-5": "2001:660:4406:691:2:1:0:10", + "kavlan-6": "2001:660:4406:692:2:1:0:10", + "kavlan-7": "2001:660:4406:693:2:1:0:10", + "kavlan-8": "2001:660:4406:694:2:1:0:10", + "kavlan-9": "2001:660:4406:695:2:1:0:10" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.16", + "ip6": "2001:660:4406:600:2:1:0:10", + "kavlan": true, "mac": "24:6e:96:6a:46:c2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-16-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/16", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json index bca564dcfaec972a63f038cb167f05c3c50845ff..904b7fd1051673d123af004b21dd2a2c5dd7cf58 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.17", "kavlan-8": "10.45.1.17", "kavlan-9": "10.45.65.17" + }, + "eth1": { + "kavlan-1": "192.168.194.17", + "kavlan-11": "10.7.241.117", + "kavlan-12": "10.11.241.117", + "kavlan-13": "10.15.241.117", + "kavlan-14": "10.19.241.117", + "kavlan-16": "10.27.241.117", + "kavlan-17": "10.31.241.117", + "kavlan-18": "10.35.241.117", + "kavlan-2": "192.168.210.17", + "kavlan-20": "10.43.241.117", + "kavlan-21": "10.47.241.117", + "kavlan-3": "192.168.226.17", + "kavlan-4": "10.44.2.17", + "kavlan-5": "10.44.66.17", + "kavlan-6": "10.44.130.17", + "kavlan-7": "10.44.194.17", + "kavlan-8": "10.45.2.17", + "kavlan-9": "10.45.66.17" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::11", "kavlan-8": "2001:660:4406:694:2::11", "kavlan-9": "2001:660:4406:695:2::11" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:11", + "kavlan-11": "2001:660:4406:1a0:602:1:0:11", + "kavlan-12": "2001:660:4406:2a0:602:1:0:11", + "kavlan-13": "2001:660:4406:4a0:602:1:0:11", + "kavlan-14": "2001:660:4406:5a0:602:1:0:11", + "kavlan-16": "2001:660:4406:7a0:602:1:0:11", + "kavlan-17": "2001:660:4406:9a0:602:1:0:11", + "kavlan-18": "2001:660:4406:8a0:602:1:0:11", + "kavlan-2": "2001:660:4406:681:2:1:0:11", + "kavlan-20": "2001:660:4406:3a0:602:1:0:11", + "kavlan-21": "2001:660:4406:6a0:602:1:0:11", + "kavlan-3": "2001:660:4406:682:2:1:0:11", + "kavlan-4": "2001:660:4406:690:2:1:0:11", + "kavlan-5": "2001:660:4406:691:2:1:0:11", + "kavlan-6": "2001:660:4406:692:2:1:0:11", + "kavlan-7": "2001:660:4406:693:2:1:0:11", + "kavlan-8": "2001:660:4406:694:2:1:0:11", + "kavlan-9": "2001:660:4406:695:2:1:0:11" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.17", + "ip6": "2001:660:4406:600:2:1:0:11", + "kavlan": true, "mac": "24:6e:96:6a:47:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-17-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/17", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json index 682f4694fb37416806352c0cff9a9559234c6298..27be6723561b8e0b5c355a1720d61d6e109e317e 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.18", "kavlan-8": "10.45.1.18", "kavlan-9": "10.45.65.18" + }, + "eth1": { + "kavlan-1": "192.168.194.18", + "kavlan-11": "10.7.241.118", + "kavlan-12": "10.11.241.118", + "kavlan-13": "10.15.241.118", + "kavlan-14": "10.19.241.118", + "kavlan-16": "10.27.241.118", + "kavlan-17": "10.31.241.118", + "kavlan-18": "10.35.241.118", + "kavlan-2": "192.168.210.18", + "kavlan-20": "10.43.241.118", + "kavlan-21": "10.47.241.118", + "kavlan-3": "192.168.226.18", + "kavlan-4": "10.44.2.18", + "kavlan-5": "10.44.66.18", + "kavlan-6": "10.44.130.18", + "kavlan-7": "10.44.194.18", + "kavlan-8": "10.45.2.18", + "kavlan-9": "10.45.66.18" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::12", "kavlan-8": "2001:660:4406:694:2::12", "kavlan-9": "2001:660:4406:695:2::12" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:12", + "kavlan-11": "2001:660:4406:1a0:602:1:0:12", + "kavlan-12": "2001:660:4406:2a0:602:1:0:12", + "kavlan-13": "2001:660:4406:4a0:602:1:0:12", + "kavlan-14": "2001:660:4406:5a0:602:1:0:12", + "kavlan-16": "2001:660:4406:7a0:602:1:0:12", + "kavlan-17": "2001:660:4406:9a0:602:1:0:12", + "kavlan-18": "2001:660:4406:8a0:602:1:0:12", + "kavlan-2": "2001:660:4406:681:2:1:0:12", + "kavlan-20": "2001:660:4406:3a0:602:1:0:12", + "kavlan-21": "2001:660:4406:6a0:602:1:0:12", + "kavlan-3": "2001:660:4406:682:2:1:0:12", + "kavlan-4": "2001:660:4406:690:2:1:0:12", + "kavlan-5": "2001:660:4406:691:2:1:0:12", + "kavlan-6": "2001:660:4406:692:2:1:0:12", + "kavlan-7": "2001:660:4406:693:2:1:0:12", + "kavlan-8": "2001:660:4406:694:2:1:0:12", + "kavlan-9": "2001:660:4406:695:2:1:0:12" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.18", + "ip6": "2001:660:4406:600:2:1:0:12", + "kavlan": true, "mac": "24:6e:96:6a:5a:5a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-18-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/18", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json index 490dfd3a527f4478676d8da4e573c870e4652aa9..5999f9dd96afad166d543eef6b6e6092f97484bc 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.19", "kavlan-8": "10.45.1.19", "kavlan-9": "10.45.65.19" + }, + "eth1": { + "kavlan-1": "192.168.194.19", + "kavlan-11": "10.7.241.119", + "kavlan-12": "10.11.241.119", + "kavlan-13": "10.15.241.119", + "kavlan-14": "10.19.241.119", + "kavlan-16": "10.27.241.119", + "kavlan-17": "10.31.241.119", + "kavlan-18": "10.35.241.119", + "kavlan-2": "192.168.210.19", + "kavlan-20": "10.43.241.119", + "kavlan-21": "10.47.241.119", + "kavlan-3": "192.168.226.19", + "kavlan-4": "10.44.2.19", + "kavlan-5": "10.44.66.19", + "kavlan-6": "10.44.130.19", + "kavlan-7": "10.44.194.19", + "kavlan-8": "10.45.2.19", + "kavlan-9": "10.45.66.19" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::13", "kavlan-8": "2001:660:4406:694:2::13", "kavlan-9": "2001:660:4406:695:2::13" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:13", + "kavlan-11": "2001:660:4406:1a0:602:1:0:13", + "kavlan-12": "2001:660:4406:2a0:602:1:0:13", + "kavlan-13": "2001:660:4406:4a0:602:1:0:13", + "kavlan-14": "2001:660:4406:5a0:602:1:0:13", + "kavlan-16": "2001:660:4406:7a0:602:1:0:13", + "kavlan-17": "2001:660:4406:9a0:602:1:0:13", + "kavlan-18": "2001:660:4406:8a0:602:1:0:13", + "kavlan-2": "2001:660:4406:681:2:1:0:13", + "kavlan-20": "2001:660:4406:3a0:602:1:0:13", + "kavlan-21": "2001:660:4406:6a0:602:1:0:13", + "kavlan-3": "2001:660:4406:682:2:1:0:13", + "kavlan-4": "2001:660:4406:690:2:1:0:13", + "kavlan-5": "2001:660:4406:691:2:1:0:13", + "kavlan-6": "2001:660:4406:692:2:1:0:13", + "kavlan-7": "2001:660:4406:693:2:1:0:13", + "kavlan-8": "2001:660:4406:694:2:1:0:13", + "kavlan-9": "2001:660:4406:695:2:1:0:13" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.19", + "ip6": "2001:660:4406:600:2:1:0:13", + "kavlan": true, "mac": "24:6e:96:6a:59:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-19-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/19", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json index 7c394e7babc607638f2bd3cde566f7301b346a50..14ff080d3ea82d00143cae12b506f68f680a4e78 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.2", "kavlan-8": "10.45.1.2", "kavlan-9": "10.45.65.2" + }, + "eth1": { + "kavlan-1": "192.168.194.2", + "kavlan-11": "10.7.241.102", + "kavlan-12": "10.11.241.102", + "kavlan-13": "10.15.241.102", + "kavlan-14": "10.19.241.102", + "kavlan-16": "10.27.241.102", + "kavlan-17": "10.31.241.102", + "kavlan-18": "10.35.241.102", + "kavlan-2": "192.168.210.2", + "kavlan-20": "10.43.241.102", + "kavlan-21": "10.47.241.102", + "kavlan-3": "192.168.226.2", + "kavlan-4": "10.44.2.2", + "kavlan-5": "10.44.66.2", + "kavlan-6": "10.44.130.2", + "kavlan-7": "10.44.194.2", + "kavlan-8": "10.45.2.2", + "kavlan-9": "10.45.66.2" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2", "kavlan-8": "2001:660:4406:694:2::2", "kavlan-9": "2001:660:4406:695:2::2" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2", + "kavlan-2": "2001:660:4406:681:2:1:0:2", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2", + "kavlan-3": "2001:660:4406:682:2:1:0:2", + "kavlan-4": "2001:660:4406:690:2:1:0:2", + "kavlan-5": "2001:660:4406:691:2:1:0:2", + "kavlan-6": "2001:660:4406:692:2:1:0:2", + "kavlan-7": "2001:660:4406:693:2:1:0:2", + "kavlan-8": "2001:660:4406:694:2:1:0:2", + "kavlan-9": "2001:660:4406:695:2:1:0:2" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.2", + "ip6": "2001:660:4406:600:2:1:0:2", + "kavlan": true, "mac": "24:6e:96:6a:d0:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-2-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/2", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json index b85d0e64a0b4ad81b3de4385f4fd0bdd5cee7eec..cbf5d16bdab0cde2ec293e80170dcf5d90f89a5e 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.20", "kavlan-8": "10.45.1.20", "kavlan-9": "10.45.65.20" + }, + "eth1": { + "kavlan-1": "192.168.194.20", + "kavlan-11": "10.7.241.120", + "kavlan-12": "10.11.241.120", + "kavlan-13": "10.15.241.120", + "kavlan-14": "10.19.241.120", + "kavlan-16": "10.27.241.120", + "kavlan-17": "10.31.241.120", + "kavlan-18": "10.35.241.120", + "kavlan-2": "192.168.210.20", + "kavlan-20": "10.43.241.120", + "kavlan-21": "10.47.241.120", + "kavlan-3": "192.168.226.20", + "kavlan-4": "10.44.2.20", + "kavlan-5": "10.44.66.20", + "kavlan-6": "10.44.130.20", + "kavlan-7": "10.44.194.20", + "kavlan-8": "10.45.2.20", + "kavlan-9": "10.45.66.20" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::14", "kavlan-8": "2001:660:4406:694:2::14", "kavlan-9": "2001:660:4406:695:2::14" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:14", + "kavlan-11": "2001:660:4406:1a0:602:1:0:14", + "kavlan-12": "2001:660:4406:2a0:602:1:0:14", + "kavlan-13": "2001:660:4406:4a0:602:1:0:14", + "kavlan-14": "2001:660:4406:5a0:602:1:0:14", + "kavlan-16": "2001:660:4406:7a0:602:1:0:14", + "kavlan-17": "2001:660:4406:9a0:602:1:0:14", + "kavlan-18": "2001:660:4406:8a0:602:1:0:14", + "kavlan-2": "2001:660:4406:681:2:1:0:14", + "kavlan-20": "2001:660:4406:3a0:602:1:0:14", + "kavlan-21": "2001:660:4406:6a0:602:1:0:14", + "kavlan-3": "2001:660:4406:682:2:1:0:14", + "kavlan-4": "2001:660:4406:690:2:1:0:14", + "kavlan-5": "2001:660:4406:691:2:1:0:14", + "kavlan-6": "2001:660:4406:692:2:1:0:14", + "kavlan-7": "2001:660:4406:693:2:1:0:14", + "kavlan-8": "2001:660:4406:694:2:1:0:14", + "kavlan-9": "2001:660:4406:695:2:1:0:14" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.20", + "ip6": "2001:660:4406:600:2:1:0:14", + "kavlan": true, "mac": "24:6e:96:6a:50:12", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-20-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/20", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json index ff6a66ed36a98fbfc1447fc883f7ed50f19a0009..991f93fd6babab2136750886811c5048793b4739 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.21", "kavlan-8": "10.45.1.21", "kavlan-9": "10.45.65.21" + }, + "eth1": { + "kavlan-1": "192.168.194.21", + "kavlan-11": "10.7.241.121", + "kavlan-12": "10.11.241.121", + "kavlan-13": "10.15.241.121", + "kavlan-14": "10.19.241.121", + "kavlan-16": "10.27.241.121", + "kavlan-17": "10.31.241.121", + "kavlan-18": "10.35.241.121", + "kavlan-2": "192.168.210.21", + "kavlan-20": "10.43.241.121", + "kavlan-21": "10.47.241.121", + "kavlan-3": "192.168.226.21", + "kavlan-4": "10.44.2.21", + "kavlan-5": "10.44.66.21", + "kavlan-6": "10.44.130.21", + "kavlan-7": "10.44.194.21", + "kavlan-8": "10.45.2.21", + "kavlan-9": "10.45.66.21" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::15", "kavlan-8": "2001:660:4406:694:2::15", "kavlan-9": "2001:660:4406:695:2::15" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:15", + "kavlan-11": "2001:660:4406:1a0:602:1:0:15", + "kavlan-12": "2001:660:4406:2a0:602:1:0:15", + "kavlan-13": "2001:660:4406:4a0:602:1:0:15", + "kavlan-14": "2001:660:4406:5a0:602:1:0:15", + "kavlan-16": "2001:660:4406:7a0:602:1:0:15", + "kavlan-17": "2001:660:4406:9a0:602:1:0:15", + "kavlan-18": "2001:660:4406:8a0:602:1:0:15", + "kavlan-2": "2001:660:4406:681:2:1:0:15", + "kavlan-20": "2001:660:4406:3a0:602:1:0:15", + "kavlan-21": "2001:660:4406:6a0:602:1:0:15", + "kavlan-3": "2001:660:4406:682:2:1:0:15", + "kavlan-4": "2001:660:4406:690:2:1:0:15", + "kavlan-5": "2001:660:4406:691:2:1:0:15", + "kavlan-6": "2001:660:4406:692:2:1:0:15", + "kavlan-7": "2001:660:4406:693:2:1:0:15", + "kavlan-8": "2001:660:4406:694:2:1:0:15", + "kavlan-9": "2001:660:4406:695:2:1:0:15" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.21", + "ip6": "2001:660:4406:600:2:1:0:15", + "kavlan": true, "mac": "24:6e:96:6a:c9:e2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-21-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/21", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json index 084c56c2f41ab102fd3a70d7b72537faeea7242a..32dfd888cbd15435cc2f10ccc6e2cfca0e3fbe13 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.22", "kavlan-8": "10.45.1.22", "kavlan-9": "10.45.65.22" + }, + "eth1": { + "kavlan-1": "192.168.194.22", + "kavlan-11": "10.7.241.122", + "kavlan-12": "10.11.241.122", + "kavlan-13": "10.15.241.122", + "kavlan-14": "10.19.241.122", + "kavlan-16": "10.27.241.122", + "kavlan-17": "10.31.241.122", + "kavlan-18": "10.35.241.122", + "kavlan-2": "192.168.210.22", + "kavlan-20": "10.43.241.122", + "kavlan-21": "10.47.241.122", + "kavlan-3": "192.168.226.22", + "kavlan-4": "10.44.2.22", + "kavlan-5": "10.44.66.22", + "kavlan-6": "10.44.130.22", + "kavlan-7": "10.44.194.22", + "kavlan-8": "10.45.2.22", + "kavlan-9": "10.45.66.22" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::16", "kavlan-8": "2001:660:4406:694:2::16", "kavlan-9": "2001:660:4406:695:2::16" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:16", + "kavlan-11": "2001:660:4406:1a0:602:1:0:16", + "kavlan-12": "2001:660:4406:2a0:602:1:0:16", + "kavlan-13": "2001:660:4406:4a0:602:1:0:16", + "kavlan-14": "2001:660:4406:5a0:602:1:0:16", + "kavlan-16": "2001:660:4406:7a0:602:1:0:16", + "kavlan-17": "2001:660:4406:9a0:602:1:0:16", + "kavlan-18": "2001:660:4406:8a0:602:1:0:16", + "kavlan-2": "2001:660:4406:681:2:1:0:16", + "kavlan-20": "2001:660:4406:3a0:602:1:0:16", + "kavlan-21": "2001:660:4406:6a0:602:1:0:16", + "kavlan-3": "2001:660:4406:682:2:1:0:16", + "kavlan-4": "2001:660:4406:690:2:1:0:16", + "kavlan-5": "2001:660:4406:691:2:1:0:16", + "kavlan-6": "2001:660:4406:692:2:1:0:16", + "kavlan-7": "2001:660:4406:693:2:1:0:16", + "kavlan-8": "2001:660:4406:694:2:1:0:16", + "kavlan-9": "2001:660:4406:695:2:1:0:16" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.22", + "ip6": "2001:660:4406:600:2:1:0:16", + "kavlan": true, "mac": "24:6e:96:6a:d3:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-22-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/22", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json index 4881c2887273d067e7abbad617c204fd3e4139d2..39beea725e84a6a341fd22a1f9d3c3aaf2b8d41e 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.23", "kavlan-8": "10.45.1.23", "kavlan-9": "10.45.65.23" + }, + "eth1": { + "kavlan-1": "192.168.194.23", + "kavlan-11": "10.7.241.123", + "kavlan-12": "10.11.241.123", + "kavlan-13": "10.15.241.123", + "kavlan-14": "10.19.241.123", + "kavlan-16": "10.27.241.123", + "kavlan-17": "10.31.241.123", + "kavlan-18": "10.35.241.123", + "kavlan-2": "192.168.210.23", + "kavlan-20": "10.43.241.123", + "kavlan-21": "10.47.241.123", + "kavlan-3": "192.168.226.23", + "kavlan-4": "10.44.2.23", + "kavlan-5": "10.44.66.23", + "kavlan-6": "10.44.130.23", + "kavlan-7": "10.44.194.23", + "kavlan-8": "10.45.2.23", + "kavlan-9": "10.45.66.23" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::17", "kavlan-8": "2001:660:4406:694:2::17", "kavlan-9": "2001:660:4406:695:2::17" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:17", + "kavlan-11": "2001:660:4406:1a0:602:1:0:17", + "kavlan-12": "2001:660:4406:2a0:602:1:0:17", + "kavlan-13": "2001:660:4406:4a0:602:1:0:17", + "kavlan-14": "2001:660:4406:5a0:602:1:0:17", + "kavlan-16": "2001:660:4406:7a0:602:1:0:17", + "kavlan-17": "2001:660:4406:9a0:602:1:0:17", + "kavlan-18": "2001:660:4406:8a0:602:1:0:17", + "kavlan-2": "2001:660:4406:681:2:1:0:17", + "kavlan-20": "2001:660:4406:3a0:602:1:0:17", + "kavlan-21": "2001:660:4406:6a0:602:1:0:17", + "kavlan-3": "2001:660:4406:682:2:1:0:17", + "kavlan-4": "2001:660:4406:690:2:1:0:17", + "kavlan-5": "2001:660:4406:691:2:1:0:17", + "kavlan-6": "2001:660:4406:692:2:1:0:17", + "kavlan-7": "2001:660:4406:693:2:1:0:17", + "kavlan-8": "2001:660:4406:694:2:1:0:17", + "kavlan-9": "2001:660:4406:695:2:1:0:17" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.23", + "ip6": "2001:660:4406:600:2:1:0:17", + "kavlan": true, "mac": "24:6e:96:6a:4e:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-23-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/23", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json index ff71f4c3751e39fbbd48b00b971c78d0638f1e78..4919bd26cfa9f20db350db39d2110b9e19005d5d 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.24", "kavlan-8": "10.45.1.24", "kavlan-9": "10.45.65.24" + }, + "eth1": { + "kavlan-1": "192.168.194.24", + "kavlan-11": "10.7.241.124", + "kavlan-12": "10.11.241.124", + "kavlan-13": "10.15.241.124", + "kavlan-14": "10.19.241.124", + "kavlan-16": "10.27.241.124", + "kavlan-17": "10.31.241.124", + "kavlan-18": "10.35.241.124", + "kavlan-2": "192.168.210.24", + "kavlan-20": "10.43.241.124", + "kavlan-21": "10.47.241.124", + "kavlan-3": "192.168.226.24", + "kavlan-4": "10.44.2.24", + "kavlan-5": "10.44.66.24", + "kavlan-6": "10.44.130.24", + "kavlan-7": "10.44.194.24", + "kavlan-8": "10.45.2.24", + "kavlan-9": "10.45.66.24" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::18", "kavlan-8": "2001:660:4406:694:2::18", "kavlan-9": "2001:660:4406:695:2::18" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:18", + "kavlan-11": "2001:660:4406:1a0:602:1:0:18", + "kavlan-12": "2001:660:4406:2a0:602:1:0:18", + "kavlan-13": "2001:660:4406:4a0:602:1:0:18", + "kavlan-14": "2001:660:4406:5a0:602:1:0:18", + "kavlan-16": "2001:660:4406:7a0:602:1:0:18", + "kavlan-17": "2001:660:4406:9a0:602:1:0:18", + "kavlan-18": "2001:660:4406:8a0:602:1:0:18", + "kavlan-2": "2001:660:4406:681:2:1:0:18", + "kavlan-20": "2001:660:4406:3a0:602:1:0:18", + "kavlan-21": "2001:660:4406:6a0:602:1:0:18", + "kavlan-3": "2001:660:4406:682:2:1:0:18", + "kavlan-4": "2001:660:4406:690:2:1:0:18", + "kavlan-5": "2001:660:4406:691:2:1:0:18", + "kavlan-6": "2001:660:4406:692:2:1:0:18", + "kavlan-7": "2001:660:4406:693:2:1:0:18", + "kavlan-8": "2001:660:4406:694:2:1:0:18", + "kavlan-9": "2001:660:4406:695:2:1:0:18" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.24", + "ip6": "2001:660:4406:600:2:1:0:18", + "kavlan": true, "mac": "24:6e:96:6a:cf:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-24-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/24", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json index df0ce3f47877e62eac2c8fe6ad128b64b06abfe0..01b4566362a2343fd18f2e7119b5e22fd248429c 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.25", "kavlan-8": "10.45.1.25", "kavlan-9": "10.45.65.25" + }, + "eth1": { + "kavlan-1": "192.168.194.25", + "kavlan-11": "10.7.241.125", + "kavlan-12": "10.11.241.125", + "kavlan-13": "10.15.241.125", + "kavlan-14": "10.19.241.125", + "kavlan-16": "10.27.241.125", + "kavlan-17": "10.31.241.125", + "kavlan-18": "10.35.241.125", + "kavlan-2": "192.168.210.25", + "kavlan-20": "10.43.241.125", + "kavlan-21": "10.47.241.125", + "kavlan-3": "192.168.226.25", + "kavlan-4": "10.44.2.25", + "kavlan-5": "10.44.66.25", + "kavlan-6": "10.44.130.25", + "kavlan-7": "10.44.194.25", + "kavlan-8": "10.45.2.25", + "kavlan-9": "10.45.66.25" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::19", "kavlan-8": "2001:660:4406:694:2::19", "kavlan-9": "2001:660:4406:695:2::19" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:19", + "kavlan-11": "2001:660:4406:1a0:602:1:0:19", + "kavlan-12": "2001:660:4406:2a0:602:1:0:19", + "kavlan-13": "2001:660:4406:4a0:602:1:0:19", + "kavlan-14": "2001:660:4406:5a0:602:1:0:19", + "kavlan-16": "2001:660:4406:7a0:602:1:0:19", + "kavlan-17": "2001:660:4406:9a0:602:1:0:19", + "kavlan-18": "2001:660:4406:8a0:602:1:0:19", + "kavlan-2": "2001:660:4406:681:2:1:0:19", + "kavlan-20": "2001:660:4406:3a0:602:1:0:19", + "kavlan-21": "2001:660:4406:6a0:602:1:0:19", + "kavlan-3": "2001:660:4406:682:2:1:0:19", + "kavlan-4": "2001:660:4406:690:2:1:0:19", + "kavlan-5": "2001:660:4406:691:2:1:0:19", + "kavlan-6": "2001:660:4406:692:2:1:0:19", + "kavlan-7": "2001:660:4406:693:2:1:0:19", + "kavlan-8": "2001:660:4406:694:2:1:0:19", + "kavlan-9": "2001:660:4406:695:2:1:0:19" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.25", + "ip6": "2001:660:4406:600:2:1:0:19", + "kavlan": true, "mac": "24:6e:96:6a:48:ba", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-25-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/25", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json index a6a540182153e6d9a4f33b9132610e2360300bc4..42182b5beb81c78d595b8960ae5a079772a515a6 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.26", "kavlan-8": "10.45.1.26", "kavlan-9": "10.45.65.26" + }, + "eth1": { + "kavlan-1": "192.168.194.26", + "kavlan-11": "10.7.241.126", + "kavlan-12": "10.11.241.126", + "kavlan-13": "10.15.241.126", + "kavlan-14": "10.19.241.126", + "kavlan-16": "10.27.241.126", + "kavlan-17": "10.31.241.126", + "kavlan-18": "10.35.241.126", + "kavlan-2": "192.168.210.26", + "kavlan-20": "10.43.241.126", + "kavlan-21": "10.47.241.126", + "kavlan-3": "192.168.226.26", + "kavlan-4": "10.44.2.26", + "kavlan-5": "10.44.66.26", + "kavlan-6": "10.44.130.26", + "kavlan-7": "10.44.194.26", + "kavlan-8": "10.45.2.26", + "kavlan-9": "10.45.66.26" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1a", "kavlan-8": "2001:660:4406:694:2::1a", "kavlan-9": "2001:660:4406:695:2::1a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1a", + "kavlan-2": "2001:660:4406:681:2:1:0:1a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1a", + "kavlan-3": "2001:660:4406:682:2:1:0:1a", + "kavlan-4": "2001:660:4406:690:2:1:0:1a", + "kavlan-5": "2001:660:4406:691:2:1:0:1a", + "kavlan-6": "2001:660:4406:692:2:1:0:1a", + "kavlan-7": "2001:660:4406:693:2:1:0:1a", + "kavlan-8": "2001:660:4406:694:2:1:0:1a", + "kavlan-9": "2001:660:4406:695:2:1:0:1a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.26", + "ip6": "2001:660:4406:600:2:1:0:1a", + "kavlan": true, "mac": "24:6e:96:6a:4e:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-26-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/26", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json index 37a7208a4a4a1f8a9a0158afd5d303d54cacb991..b080d9fa8bb5059fe74c999ccc73512c2e6aa5eb 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.27", "kavlan-8": "10.45.1.27", "kavlan-9": "10.45.65.27" + }, + "eth1": { + "kavlan-1": "192.168.194.27", + "kavlan-11": "10.7.241.127", + "kavlan-12": "10.11.241.127", + "kavlan-13": "10.15.241.127", + "kavlan-14": "10.19.241.127", + "kavlan-16": "10.27.241.127", + "kavlan-17": "10.31.241.127", + "kavlan-18": "10.35.241.127", + "kavlan-2": "192.168.210.27", + "kavlan-20": "10.43.241.127", + "kavlan-21": "10.47.241.127", + "kavlan-3": "192.168.226.27", + "kavlan-4": "10.44.2.27", + "kavlan-5": "10.44.66.27", + "kavlan-6": "10.44.130.27", + "kavlan-7": "10.44.194.27", + "kavlan-8": "10.45.2.27", + "kavlan-9": "10.45.66.27" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1b", "kavlan-8": "2001:660:4406:694:2::1b", "kavlan-9": "2001:660:4406:695:2::1b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1b", + "kavlan-2": "2001:660:4406:681:2:1:0:1b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1b", + "kavlan-3": "2001:660:4406:682:2:1:0:1b", + "kavlan-4": "2001:660:4406:690:2:1:0:1b", + "kavlan-5": "2001:660:4406:691:2:1:0:1b", + "kavlan-6": "2001:660:4406:692:2:1:0:1b", + "kavlan-7": "2001:660:4406:693:2:1:0:1b", + "kavlan-8": "2001:660:4406:694:2:1:0:1b", + "kavlan-9": "2001:660:4406:695:2:1:0:1b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.27", + "ip6": "2001:660:4406:600:2:1:0:1b", + "kavlan": true, "mac": "24:6e:96:6a:d9:fa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-27-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/27", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json index d5b60e4b22f52ed7378a7ed2a1e3bf71169a0d16..f6374ff43ed0de8ce47085a67af0a12d4da1e06a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.28", "kavlan-8": "10.45.1.28", "kavlan-9": "10.45.65.28" + }, + "eth1": { + "kavlan-1": "192.168.194.28", + "kavlan-11": "10.7.241.128", + "kavlan-12": "10.11.241.128", + "kavlan-13": "10.15.241.128", + "kavlan-14": "10.19.241.128", + "kavlan-16": "10.27.241.128", + "kavlan-17": "10.31.241.128", + "kavlan-18": "10.35.241.128", + "kavlan-2": "192.168.210.28", + "kavlan-20": "10.43.241.128", + "kavlan-21": "10.47.241.128", + "kavlan-3": "192.168.226.28", + "kavlan-4": "10.44.2.28", + "kavlan-5": "10.44.66.28", + "kavlan-6": "10.44.130.28", + "kavlan-7": "10.44.194.28", + "kavlan-8": "10.45.2.28", + "kavlan-9": "10.45.66.28" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1c", "kavlan-8": "2001:660:4406:694:2::1c", "kavlan-9": "2001:660:4406:695:2::1c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1c", + "kavlan-2": "2001:660:4406:681:2:1:0:1c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1c", + "kavlan-3": "2001:660:4406:682:2:1:0:1c", + "kavlan-4": "2001:660:4406:690:2:1:0:1c", + "kavlan-5": "2001:660:4406:691:2:1:0:1c", + "kavlan-6": "2001:660:4406:692:2:1:0:1c", + "kavlan-7": "2001:660:4406:693:2:1:0:1c", + "kavlan-8": "2001:660:4406:694:2:1:0:1c", + "kavlan-9": "2001:660:4406:695:2:1:0:1c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.28", + "ip6": "2001:660:4406:600:2:1:0:1c", + "kavlan": true, "mac": "24:6e:96:6a:ca:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-28-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/28", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json index a728bca1d2f9121d5075087ab0eeab70ec88337e..5f3066215dc793fffe9218001e889978296b7ee0 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.29", "kavlan-8": "10.45.1.29", "kavlan-9": "10.45.65.29" + }, + "eth1": { + "kavlan-1": "192.168.194.29", + "kavlan-11": "10.7.241.129", + "kavlan-12": "10.11.241.129", + "kavlan-13": "10.15.241.129", + "kavlan-14": "10.19.241.129", + "kavlan-16": "10.27.241.129", + "kavlan-17": "10.31.241.129", + "kavlan-18": "10.35.241.129", + "kavlan-2": "192.168.210.29", + "kavlan-20": "10.43.241.129", + "kavlan-21": "10.47.241.129", + "kavlan-3": "192.168.226.29", + "kavlan-4": "10.44.2.29", + "kavlan-5": "10.44.66.29", + "kavlan-6": "10.44.130.29", + "kavlan-7": "10.44.194.29", + "kavlan-8": "10.45.2.29", + "kavlan-9": "10.45.66.29" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1d", "kavlan-8": "2001:660:4406:694:2::1d", "kavlan-9": "2001:660:4406:695:2::1d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1d", + "kavlan-2": "2001:660:4406:681:2:1:0:1d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1d", + "kavlan-3": "2001:660:4406:682:2:1:0:1d", + "kavlan-4": "2001:660:4406:690:2:1:0:1d", + "kavlan-5": "2001:660:4406:691:2:1:0:1d", + "kavlan-6": "2001:660:4406:692:2:1:0:1d", + "kavlan-7": "2001:660:4406:693:2:1:0:1d", + "kavlan-8": "2001:660:4406:694:2:1:0:1d", + "kavlan-9": "2001:660:4406:695:2:1:0:1d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.29", + "ip6": "2001:660:4406:600:2:1:0:1d", + "kavlan": true, "mac": "24:6e:96:6a:d8:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-29-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/29", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json index bda941dd4b06ad59f7f675b6a45bd887034b9116..13678b64492c80923edaacd5685ef73ff1ce78c9 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.3", "kavlan-8": "10.45.1.3", "kavlan-9": "10.45.65.3" + }, + "eth1": { + "kavlan-1": "192.168.194.3", + "kavlan-11": "10.7.241.103", + "kavlan-12": "10.11.241.103", + "kavlan-13": "10.15.241.103", + "kavlan-14": "10.19.241.103", + "kavlan-16": "10.27.241.103", + "kavlan-17": "10.31.241.103", + "kavlan-18": "10.35.241.103", + "kavlan-2": "192.168.210.3", + "kavlan-20": "10.43.241.103", + "kavlan-21": "10.47.241.103", + "kavlan-3": "192.168.226.3", + "kavlan-4": "10.44.2.3", + "kavlan-5": "10.44.66.3", + "kavlan-6": "10.44.130.3", + "kavlan-7": "10.44.194.3", + "kavlan-8": "10.45.2.3", + "kavlan-9": "10.45.66.3" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::3", "kavlan-8": "2001:660:4406:694:2::3", "kavlan-9": "2001:660:4406:695:2::3" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:3", + "kavlan-11": "2001:660:4406:1a0:602:1:0:3", + "kavlan-12": "2001:660:4406:2a0:602:1:0:3", + "kavlan-13": "2001:660:4406:4a0:602:1:0:3", + "kavlan-14": "2001:660:4406:5a0:602:1:0:3", + "kavlan-16": "2001:660:4406:7a0:602:1:0:3", + "kavlan-17": "2001:660:4406:9a0:602:1:0:3", + "kavlan-18": "2001:660:4406:8a0:602:1:0:3", + "kavlan-2": "2001:660:4406:681:2:1:0:3", + "kavlan-20": "2001:660:4406:3a0:602:1:0:3", + "kavlan-21": "2001:660:4406:6a0:602:1:0:3", + "kavlan-3": "2001:660:4406:682:2:1:0:3", + "kavlan-4": "2001:660:4406:690:2:1:0:3", + "kavlan-5": "2001:660:4406:691:2:1:0:3", + "kavlan-6": "2001:660:4406:692:2:1:0:3", + "kavlan-7": "2001:660:4406:693:2:1:0:3", + "kavlan-8": "2001:660:4406:694:2:1:0:3", + "kavlan-9": "2001:660:4406:695:2:1:0:3" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.3", + "ip6": "2001:660:4406:600:2:1:0:3", + "kavlan": true, "mac": "24:6e:96:6a:d7:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-3-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/3", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json index f17a4ccc750411ab051ee3971a61a5d1ea386177..7bd9b7b861edecc96f4652a92e971dfa6a5ab811 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.30", "kavlan-8": "10.45.1.30", "kavlan-9": "10.45.65.30" + }, + "eth1": { + "kavlan-1": "192.168.194.30", + "kavlan-11": "10.7.241.130", + "kavlan-12": "10.11.241.130", + "kavlan-13": "10.15.241.130", + "kavlan-14": "10.19.241.130", + "kavlan-16": "10.27.241.130", + "kavlan-17": "10.31.241.130", + "kavlan-18": "10.35.241.130", + "kavlan-2": "192.168.210.30", + "kavlan-20": "10.43.241.130", + "kavlan-21": "10.47.241.130", + "kavlan-3": "192.168.226.30", + "kavlan-4": "10.44.2.30", + "kavlan-5": "10.44.66.30", + "kavlan-6": "10.44.130.30", + "kavlan-7": "10.44.194.30", + "kavlan-8": "10.45.2.30", + "kavlan-9": "10.45.66.30" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1e", "kavlan-8": "2001:660:4406:694:2::1e", "kavlan-9": "2001:660:4406:695:2::1e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1e", + "kavlan-2": "2001:660:4406:681:2:1:0:1e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1e", + "kavlan-3": "2001:660:4406:682:2:1:0:1e", + "kavlan-4": "2001:660:4406:690:2:1:0:1e", + "kavlan-5": "2001:660:4406:691:2:1:0:1e", + "kavlan-6": "2001:660:4406:692:2:1:0:1e", + "kavlan-7": "2001:660:4406:693:2:1:0:1e", + "kavlan-8": "2001:660:4406:694:2:1:0:1e", + "kavlan-9": "2001:660:4406:695:2:1:0:1e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.30", + "ip6": "2001:660:4406:600:2:1:0:1e", + "kavlan": true, "mac": "24:6e:96:6a:51:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-30-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/30", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json index 074c4c7b49a0e4ec3058b6c14de6fcb682a04110..1c2cd030bd1584af46156c48b1750376d92e8576 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.31", "kavlan-8": "10.45.1.31", "kavlan-9": "10.45.65.31" + }, + "eth1": { + "kavlan-1": "192.168.194.31", + "kavlan-11": "10.7.241.131", + "kavlan-12": "10.11.241.131", + "kavlan-13": "10.15.241.131", + "kavlan-14": "10.19.241.131", + "kavlan-16": "10.27.241.131", + "kavlan-17": "10.31.241.131", + "kavlan-18": "10.35.241.131", + "kavlan-2": "192.168.210.31", + "kavlan-20": "10.43.241.131", + "kavlan-21": "10.47.241.131", + "kavlan-3": "192.168.226.31", + "kavlan-4": "10.44.2.31", + "kavlan-5": "10.44.66.31", + "kavlan-6": "10.44.130.31", + "kavlan-7": "10.44.194.31", + "kavlan-8": "10.45.2.31", + "kavlan-9": "10.45.66.31" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::1f", "kavlan-8": "2001:660:4406:694:2::1f", "kavlan-9": "2001:660:4406:695:2::1f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:1f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:1f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:1f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:1f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:1f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:1f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:1f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:1f", + "kavlan-2": "2001:660:4406:681:2:1:0:1f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:1f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:1f", + "kavlan-3": "2001:660:4406:682:2:1:0:1f", + "kavlan-4": "2001:660:4406:690:2:1:0:1f", + "kavlan-5": "2001:660:4406:691:2:1:0:1f", + "kavlan-6": "2001:660:4406:692:2:1:0:1f", + "kavlan-7": "2001:660:4406:693:2:1:0:1f", + "kavlan-8": "2001:660:4406:694:2:1:0:1f", + "kavlan-9": "2001:660:4406:695:2:1:0:1f" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.31", + "ip6": "2001:660:4406:600:2:1:0:1f", + "kavlan": true, "mac": "24:6e:96:6a:d8:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-31-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/31", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json index 67661503b4ef7a9109533e82b09e56941f7efb36..63c0e726e4d2521603b953db6733bc22bc2377b3 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.32", "kavlan-8": "10.45.1.32", "kavlan-9": "10.45.65.32" + }, + "eth1": { + "kavlan-1": "192.168.194.32", + "kavlan-11": "10.7.241.132", + "kavlan-12": "10.11.241.132", + "kavlan-13": "10.15.241.132", + "kavlan-14": "10.19.241.132", + "kavlan-16": "10.27.241.132", + "kavlan-17": "10.31.241.132", + "kavlan-18": "10.35.241.132", + "kavlan-2": "192.168.210.32", + "kavlan-20": "10.43.241.132", + "kavlan-21": "10.47.241.132", + "kavlan-3": "192.168.226.32", + "kavlan-4": "10.44.2.32", + "kavlan-5": "10.44.66.32", + "kavlan-6": "10.44.130.32", + "kavlan-7": "10.44.194.32", + "kavlan-8": "10.45.2.32", + "kavlan-9": "10.45.66.32" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::20", "kavlan-8": "2001:660:4406:694:2::20", "kavlan-9": "2001:660:4406:695:2::20" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:20", + "kavlan-11": "2001:660:4406:1a0:602:1:0:20", + "kavlan-12": "2001:660:4406:2a0:602:1:0:20", + "kavlan-13": "2001:660:4406:4a0:602:1:0:20", + "kavlan-14": "2001:660:4406:5a0:602:1:0:20", + "kavlan-16": "2001:660:4406:7a0:602:1:0:20", + "kavlan-17": "2001:660:4406:9a0:602:1:0:20", + "kavlan-18": "2001:660:4406:8a0:602:1:0:20", + "kavlan-2": "2001:660:4406:681:2:1:0:20", + "kavlan-20": "2001:660:4406:3a0:602:1:0:20", + "kavlan-21": "2001:660:4406:6a0:602:1:0:20", + "kavlan-3": "2001:660:4406:682:2:1:0:20", + "kavlan-4": "2001:660:4406:690:2:1:0:20", + "kavlan-5": "2001:660:4406:691:2:1:0:20", + "kavlan-6": "2001:660:4406:692:2:1:0:20", + "kavlan-7": "2001:660:4406:693:2:1:0:20", + "kavlan-8": "2001:660:4406:694:2:1:0:20", + "kavlan-9": "2001:660:4406:695:2:1:0:20" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.32", + "ip6": "2001:660:4406:600:2:1:0:20", + "kavlan": true, "mac": "24:6e:96:6a:d6:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-32-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/32", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json index cc598d0401ac9dcacc4356bba4aa4c8aad06b14f..9abc9a900039c305facf0cb19f2bec350a699fd0 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.33", "kavlan-8": "10.45.1.33", "kavlan-9": "10.45.65.33" + }, + "eth1": { + "kavlan-1": "192.168.194.33", + "kavlan-11": "10.7.241.133", + "kavlan-12": "10.11.241.133", + "kavlan-13": "10.15.241.133", + "kavlan-14": "10.19.241.133", + "kavlan-16": "10.27.241.133", + "kavlan-17": "10.31.241.133", + "kavlan-18": "10.35.241.133", + "kavlan-2": "192.168.210.33", + "kavlan-20": "10.43.241.133", + "kavlan-21": "10.47.241.133", + "kavlan-3": "192.168.226.33", + "kavlan-4": "10.44.2.33", + "kavlan-5": "10.44.66.33", + "kavlan-6": "10.44.130.33", + "kavlan-7": "10.44.194.33", + "kavlan-8": "10.45.2.33", + "kavlan-9": "10.45.66.33" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::21", "kavlan-8": "2001:660:4406:694:2::21", "kavlan-9": "2001:660:4406:695:2::21" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:21", + "kavlan-11": "2001:660:4406:1a0:602:1:0:21", + "kavlan-12": "2001:660:4406:2a0:602:1:0:21", + "kavlan-13": "2001:660:4406:4a0:602:1:0:21", + "kavlan-14": "2001:660:4406:5a0:602:1:0:21", + "kavlan-16": "2001:660:4406:7a0:602:1:0:21", + "kavlan-17": "2001:660:4406:9a0:602:1:0:21", + "kavlan-18": "2001:660:4406:8a0:602:1:0:21", + "kavlan-2": "2001:660:4406:681:2:1:0:21", + "kavlan-20": "2001:660:4406:3a0:602:1:0:21", + "kavlan-21": "2001:660:4406:6a0:602:1:0:21", + "kavlan-3": "2001:660:4406:682:2:1:0:21", + "kavlan-4": "2001:660:4406:690:2:1:0:21", + "kavlan-5": "2001:660:4406:691:2:1:0:21", + "kavlan-6": "2001:660:4406:692:2:1:0:21", + "kavlan-7": "2001:660:4406:693:2:1:0:21", + "kavlan-8": "2001:660:4406:694:2:1:0:21", + "kavlan-9": "2001:660:4406:695:2:1:0:21" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.33", + "ip6": "2001:660:4406:600:2:1:0:21", + "kavlan": true, "mac": "24:6e:96:6a:4e:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-33-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/33", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json index 84ef304e1ad6dda14baded749fd68c9c5eca1398..c6534f6902a60c1af2b563f2ab4863de0b133f86 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.34", "kavlan-8": "10.45.1.34", "kavlan-9": "10.45.65.34" + }, + "eth1": { + "kavlan-1": "192.168.194.34", + "kavlan-11": "10.7.241.134", + "kavlan-12": "10.11.241.134", + "kavlan-13": "10.15.241.134", + "kavlan-14": "10.19.241.134", + "kavlan-16": "10.27.241.134", + "kavlan-17": "10.31.241.134", + "kavlan-18": "10.35.241.134", + "kavlan-2": "192.168.210.34", + "kavlan-20": "10.43.241.134", + "kavlan-21": "10.47.241.134", + "kavlan-3": "192.168.226.34", + "kavlan-4": "10.44.2.34", + "kavlan-5": "10.44.66.34", + "kavlan-6": "10.44.130.34", + "kavlan-7": "10.44.194.34", + "kavlan-8": "10.45.2.34", + "kavlan-9": "10.45.66.34" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::22", "kavlan-8": "2001:660:4406:694:2::22", "kavlan-9": "2001:660:4406:695:2::22" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:22", + "kavlan-11": "2001:660:4406:1a0:602:1:0:22", + "kavlan-12": "2001:660:4406:2a0:602:1:0:22", + "kavlan-13": "2001:660:4406:4a0:602:1:0:22", + "kavlan-14": "2001:660:4406:5a0:602:1:0:22", + "kavlan-16": "2001:660:4406:7a0:602:1:0:22", + "kavlan-17": "2001:660:4406:9a0:602:1:0:22", + "kavlan-18": "2001:660:4406:8a0:602:1:0:22", + "kavlan-2": "2001:660:4406:681:2:1:0:22", + "kavlan-20": "2001:660:4406:3a0:602:1:0:22", + "kavlan-21": "2001:660:4406:6a0:602:1:0:22", + "kavlan-3": "2001:660:4406:682:2:1:0:22", + "kavlan-4": "2001:660:4406:690:2:1:0:22", + "kavlan-5": "2001:660:4406:691:2:1:0:22", + "kavlan-6": "2001:660:4406:692:2:1:0:22", + "kavlan-7": "2001:660:4406:693:2:1:0:22", + "kavlan-8": "2001:660:4406:694:2:1:0:22", + "kavlan-9": "2001:660:4406:695:2:1:0:22" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.34", + "ip6": "2001:660:4406:600:2:1:0:22", + "kavlan": true, "mac": "24:6e:96:6a:c9:4a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-34-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/34", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json index 120e47fe105c1235d3b3e149d4bda9bf3912bf64..1bad5b56bf0da627baf8ae37db6c35e0f1521ff5 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.35", "kavlan-8": "10.45.1.35", "kavlan-9": "10.45.65.35" + }, + "eth1": { + "kavlan-1": "192.168.194.35", + "kavlan-11": "10.7.241.135", + "kavlan-12": "10.11.241.135", + "kavlan-13": "10.15.241.135", + "kavlan-14": "10.19.241.135", + "kavlan-16": "10.27.241.135", + "kavlan-17": "10.31.241.135", + "kavlan-18": "10.35.241.135", + "kavlan-2": "192.168.210.35", + "kavlan-20": "10.43.241.135", + "kavlan-21": "10.47.241.135", + "kavlan-3": "192.168.226.35", + "kavlan-4": "10.44.2.35", + "kavlan-5": "10.44.66.35", + "kavlan-6": "10.44.130.35", + "kavlan-7": "10.44.194.35", + "kavlan-8": "10.45.2.35", + "kavlan-9": "10.45.66.35" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::23", "kavlan-8": "2001:660:4406:694:2::23", "kavlan-9": "2001:660:4406:695:2::23" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:23", + "kavlan-11": "2001:660:4406:1a0:602:1:0:23", + "kavlan-12": "2001:660:4406:2a0:602:1:0:23", + "kavlan-13": "2001:660:4406:4a0:602:1:0:23", + "kavlan-14": "2001:660:4406:5a0:602:1:0:23", + "kavlan-16": "2001:660:4406:7a0:602:1:0:23", + "kavlan-17": "2001:660:4406:9a0:602:1:0:23", + "kavlan-18": "2001:660:4406:8a0:602:1:0:23", + "kavlan-2": "2001:660:4406:681:2:1:0:23", + "kavlan-20": "2001:660:4406:3a0:602:1:0:23", + "kavlan-21": "2001:660:4406:6a0:602:1:0:23", + "kavlan-3": "2001:660:4406:682:2:1:0:23", + "kavlan-4": "2001:660:4406:690:2:1:0:23", + "kavlan-5": "2001:660:4406:691:2:1:0:23", + "kavlan-6": "2001:660:4406:692:2:1:0:23", + "kavlan-7": "2001:660:4406:693:2:1:0:23", + "kavlan-8": "2001:660:4406:694:2:1:0:23", + "kavlan-9": "2001:660:4406:695:2:1:0:23" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.35", + "ip6": "2001:660:4406:600:2:1:0:23", + "kavlan": true, "mac": "24:6e:96:6a:d1:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-35-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/35", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json index f71750f0021591c545ecb828f367849355218ce6..654a103cfc1853f4e0d58cb1b9cc07318b2c6448 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.36", "kavlan-8": "10.45.1.36", "kavlan-9": "10.45.65.36" + }, + "eth1": { + "kavlan-1": "192.168.194.36", + "kavlan-11": "10.7.241.136", + "kavlan-12": "10.11.241.136", + "kavlan-13": "10.15.241.136", + "kavlan-14": "10.19.241.136", + "kavlan-16": "10.27.241.136", + "kavlan-17": "10.31.241.136", + "kavlan-18": "10.35.241.136", + "kavlan-2": "192.168.210.36", + "kavlan-20": "10.43.241.136", + "kavlan-21": "10.47.241.136", + "kavlan-3": "192.168.226.36", + "kavlan-4": "10.44.2.36", + "kavlan-5": "10.44.66.36", + "kavlan-6": "10.44.130.36", + "kavlan-7": "10.44.194.36", + "kavlan-8": "10.45.2.36", + "kavlan-9": "10.45.66.36" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::24", "kavlan-8": "2001:660:4406:694:2::24", "kavlan-9": "2001:660:4406:695:2::24" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:24", + "kavlan-11": "2001:660:4406:1a0:602:1:0:24", + "kavlan-12": "2001:660:4406:2a0:602:1:0:24", + "kavlan-13": "2001:660:4406:4a0:602:1:0:24", + "kavlan-14": "2001:660:4406:5a0:602:1:0:24", + "kavlan-16": "2001:660:4406:7a0:602:1:0:24", + "kavlan-17": "2001:660:4406:9a0:602:1:0:24", + "kavlan-18": "2001:660:4406:8a0:602:1:0:24", + "kavlan-2": "2001:660:4406:681:2:1:0:24", + "kavlan-20": "2001:660:4406:3a0:602:1:0:24", + "kavlan-21": "2001:660:4406:6a0:602:1:0:24", + "kavlan-3": "2001:660:4406:682:2:1:0:24", + "kavlan-4": "2001:660:4406:690:2:1:0:24", + "kavlan-5": "2001:660:4406:691:2:1:0:24", + "kavlan-6": "2001:660:4406:692:2:1:0:24", + "kavlan-7": "2001:660:4406:693:2:1:0:24", + "kavlan-8": "2001:660:4406:694:2:1:0:24", + "kavlan-9": "2001:660:4406:695:2:1:0:24" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.36", + "ip6": "2001:660:4406:600:2:1:0:24", + "kavlan": true, "mac": "24:6e:96:6a:56:62", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-36-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/36", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json index 63a009ecd861ab77e97adfd86ebd30bab03255bb..139513bb69a25f4ba70df27243ea90b6efa203a7 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.37", "kavlan-8": "10.45.1.37", "kavlan-9": "10.45.65.37" + }, + "eth1": { + "kavlan-1": "192.168.194.37", + "kavlan-11": "10.7.241.137", + "kavlan-12": "10.11.241.137", + "kavlan-13": "10.15.241.137", + "kavlan-14": "10.19.241.137", + "kavlan-16": "10.27.241.137", + "kavlan-17": "10.31.241.137", + "kavlan-18": "10.35.241.137", + "kavlan-2": "192.168.210.37", + "kavlan-20": "10.43.241.137", + "kavlan-21": "10.47.241.137", + "kavlan-3": "192.168.226.37", + "kavlan-4": "10.44.2.37", + "kavlan-5": "10.44.66.37", + "kavlan-6": "10.44.130.37", + "kavlan-7": "10.44.194.37", + "kavlan-8": "10.45.2.37", + "kavlan-9": "10.45.66.37" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::25", "kavlan-8": "2001:660:4406:694:2::25", "kavlan-9": "2001:660:4406:695:2::25" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:25", + "kavlan-11": "2001:660:4406:1a0:602:1:0:25", + "kavlan-12": "2001:660:4406:2a0:602:1:0:25", + "kavlan-13": "2001:660:4406:4a0:602:1:0:25", + "kavlan-14": "2001:660:4406:5a0:602:1:0:25", + "kavlan-16": "2001:660:4406:7a0:602:1:0:25", + "kavlan-17": "2001:660:4406:9a0:602:1:0:25", + "kavlan-18": "2001:660:4406:8a0:602:1:0:25", + "kavlan-2": "2001:660:4406:681:2:1:0:25", + "kavlan-20": "2001:660:4406:3a0:602:1:0:25", + "kavlan-21": "2001:660:4406:6a0:602:1:0:25", + "kavlan-3": "2001:660:4406:682:2:1:0:25", + "kavlan-4": "2001:660:4406:690:2:1:0:25", + "kavlan-5": "2001:660:4406:691:2:1:0:25", + "kavlan-6": "2001:660:4406:692:2:1:0:25", + "kavlan-7": "2001:660:4406:693:2:1:0:25", + "kavlan-8": "2001:660:4406:694:2:1:0:25", + "kavlan-9": "2001:660:4406:695:2:1:0:25" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.37", + "ip6": "2001:660:4406:600:2:1:0:25", + "kavlan": true, "mac": "24:6e:96:6a:cc:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-37-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/37", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json index cca8281d27752d8448c932fbca1a6006e10f6daa..74c467b56e0825e2e784bc2c641fe361fffa8c31 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.38", "kavlan-8": "10.45.1.38", "kavlan-9": "10.45.65.38" + }, + "eth1": { + "kavlan-1": "192.168.194.38", + "kavlan-11": "10.7.241.138", + "kavlan-12": "10.11.241.138", + "kavlan-13": "10.15.241.138", + "kavlan-14": "10.19.241.138", + "kavlan-16": "10.27.241.138", + "kavlan-17": "10.31.241.138", + "kavlan-18": "10.35.241.138", + "kavlan-2": "192.168.210.38", + "kavlan-20": "10.43.241.138", + "kavlan-21": "10.47.241.138", + "kavlan-3": "192.168.226.38", + "kavlan-4": "10.44.2.38", + "kavlan-5": "10.44.66.38", + "kavlan-6": "10.44.130.38", + "kavlan-7": "10.44.194.38", + "kavlan-8": "10.45.2.38", + "kavlan-9": "10.45.66.38" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::26", "kavlan-8": "2001:660:4406:694:2::26", "kavlan-9": "2001:660:4406:695:2::26" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:26", + "kavlan-11": "2001:660:4406:1a0:602:1:0:26", + "kavlan-12": "2001:660:4406:2a0:602:1:0:26", + "kavlan-13": "2001:660:4406:4a0:602:1:0:26", + "kavlan-14": "2001:660:4406:5a0:602:1:0:26", + "kavlan-16": "2001:660:4406:7a0:602:1:0:26", + "kavlan-17": "2001:660:4406:9a0:602:1:0:26", + "kavlan-18": "2001:660:4406:8a0:602:1:0:26", + "kavlan-2": "2001:660:4406:681:2:1:0:26", + "kavlan-20": "2001:660:4406:3a0:602:1:0:26", + "kavlan-21": "2001:660:4406:6a0:602:1:0:26", + "kavlan-3": "2001:660:4406:682:2:1:0:26", + "kavlan-4": "2001:660:4406:690:2:1:0:26", + "kavlan-5": "2001:660:4406:691:2:1:0:26", + "kavlan-6": "2001:660:4406:692:2:1:0:26", + "kavlan-7": "2001:660:4406:693:2:1:0:26", + "kavlan-8": "2001:660:4406:694:2:1:0:26", + "kavlan-9": "2001:660:4406:695:2:1:0:26" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.38", + "ip6": "2001:660:4406:600:2:1:0:26", + "kavlan": true, "mac": "24:6e:96:6a:d7:8a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-38-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/38", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json index 1b275ca395726d1bdf87686f8f50fe533c508570..52831b90714c152701408e54b3e11965b224f0d9 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.39", "kavlan-8": "10.45.1.39", "kavlan-9": "10.45.65.39" + }, + "eth1": { + "kavlan-1": "192.168.194.39", + "kavlan-11": "10.7.241.139", + "kavlan-12": "10.11.241.139", + "kavlan-13": "10.15.241.139", + "kavlan-14": "10.19.241.139", + "kavlan-16": "10.27.241.139", + "kavlan-17": "10.31.241.139", + "kavlan-18": "10.35.241.139", + "kavlan-2": "192.168.210.39", + "kavlan-20": "10.43.241.139", + "kavlan-21": "10.47.241.139", + "kavlan-3": "192.168.226.39", + "kavlan-4": "10.44.2.39", + "kavlan-5": "10.44.66.39", + "kavlan-6": "10.44.130.39", + "kavlan-7": "10.44.194.39", + "kavlan-8": "10.45.2.39", + "kavlan-9": "10.45.66.39" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::27", "kavlan-8": "2001:660:4406:694:2::27", "kavlan-9": "2001:660:4406:695:2::27" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:27", + "kavlan-11": "2001:660:4406:1a0:602:1:0:27", + "kavlan-12": "2001:660:4406:2a0:602:1:0:27", + "kavlan-13": "2001:660:4406:4a0:602:1:0:27", + "kavlan-14": "2001:660:4406:5a0:602:1:0:27", + "kavlan-16": "2001:660:4406:7a0:602:1:0:27", + "kavlan-17": "2001:660:4406:9a0:602:1:0:27", + "kavlan-18": "2001:660:4406:8a0:602:1:0:27", + "kavlan-2": "2001:660:4406:681:2:1:0:27", + "kavlan-20": "2001:660:4406:3a0:602:1:0:27", + "kavlan-21": "2001:660:4406:6a0:602:1:0:27", + "kavlan-3": "2001:660:4406:682:2:1:0:27", + "kavlan-4": "2001:660:4406:690:2:1:0:27", + "kavlan-5": "2001:660:4406:691:2:1:0:27", + "kavlan-6": "2001:660:4406:692:2:1:0:27", + "kavlan-7": "2001:660:4406:693:2:1:0:27", + "kavlan-8": "2001:660:4406:694:2:1:0:27", + "kavlan-9": "2001:660:4406:695:2:1:0:27" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.39", + "ip6": "2001:660:4406:600:2:1:0:27", + "kavlan": true, "mac": "24:6e:96:6a:d1:1a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-39-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/39", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json index 5813bf464afd3b5c1be2d75aeae37170f378fd13..f783897770baa92ca94682219fb6005d312633f7 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.4", "kavlan-8": "10.45.1.4", "kavlan-9": "10.45.65.4" + }, + "eth1": { + "kavlan-1": "192.168.194.4", + "kavlan-11": "10.7.241.104", + "kavlan-12": "10.11.241.104", + "kavlan-13": "10.15.241.104", + "kavlan-14": "10.19.241.104", + "kavlan-16": "10.27.241.104", + "kavlan-17": "10.31.241.104", + "kavlan-18": "10.35.241.104", + "kavlan-2": "192.168.210.4", + "kavlan-20": "10.43.241.104", + "kavlan-21": "10.47.241.104", + "kavlan-3": "192.168.226.4", + "kavlan-4": "10.44.2.4", + "kavlan-5": "10.44.66.4", + "kavlan-6": "10.44.130.4", + "kavlan-7": "10.44.194.4", + "kavlan-8": "10.45.2.4", + "kavlan-9": "10.45.66.4" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::4", "kavlan-8": "2001:660:4406:694:2::4", "kavlan-9": "2001:660:4406:695:2::4" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:4", + "kavlan-11": "2001:660:4406:1a0:602:1:0:4", + "kavlan-12": "2001:660:4406:2a0:602:1:0:4", + "kavlan-13": "2001:660:4406:4a0:602:1:0:4", + "kavlan-14": "2001:660:4406:5a0:602:1:0:4", + "kavlan-16": "2001:660:4406:7a0:602:1:0:4", + "kavlan-17": "2001:660:4406:9a0:602:1:0:4", + "kavlan-18": "2001:660:4406:8a0:602:1:0:4", + "kavlan-2": "2001:660:4406:681:2:1:0:4", + "kavlan-20": "2001:660:4406:3a0:602:1:0:4", + "kavlan-21": "2001:660:4406:6a0:602:1:0:4", + "kavlan-3": "2001:660:4406:682:2:1:0:4", + "kavlan-4": "2001:660:4406:690:2:1:0:4", + "kavlan-5": "2001:660:4406:691:2:1:0:4", + "kavlan-6": "2001:660:4406:692:2:1:0:4", + "kavlan-7": "2001:660:4406:693:2:1:0:4", + "kavlan-8": "2001:660:4406:694:2:1:0:4", + "kavlan-9": "2001:660:4406:695:2:1:0:4" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.4", + "ip6": "2001:660:4406:600:2:1:0:4", + "kavlan": true, "mac": "24:6e:96:6a:d7:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-4-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/4", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json index 4ea369bd5f55d7c1433c28b5ae7fa5fe0e2be1b4..09b9e63b2f2f66c910204fc723e32e26bd820922 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.40", "kavlan-8": "10.45.1.40", "kavlan-9": "10.45.65.40" + }, + "eth1": { + "kavlan-1": "192.168.194.40", + "kavlan-11": "10.7.241.140", + "kavlan-12": "10.11.241.140", + "kavlan-13": "10.15.241.140", + "kavlan-14": "10.19.241.140", + "kavlan-16": "10.27.241.140", + "kavlan-17": "10.31.241.140", + "kavlan-18": "10.35.241.140", + "kavlan-2": "192.168.210.40", + "kavlan-20": "10.43.241.140", + "kavlan-21": "10.47.241.140", + "kavlan-3": "192.168.226.40", + "kavlan-4": "10.44.2.40", + "kavlan-5": "10.44.66.40", + "kavlan-6": "10.44.130.40", + "kavlan-7": "10.44.194.40", + "kavlan-8": "10.45.2.40", + "kavlan-9": "10.45.66.40" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::28", "kavlan-8": "2001:660:4406:694:2::28", "kavlan-9": "2001:660:4406:695:2::28" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:28", + "kavlan-11": "2001:660:4406:1a0:602:1:0:28", + "kavlan-12": "2001:660:4406:2a0:602:1:0:28", + "kavlan-13": "2001:660:4406:4a0:602:1:0:28", + "kavlan-14": "2001:660:4406:5a0:602:1:0:28", + "kavlan-16": "2001:660:4406:7a0:602:1:0:28", + "kavlan-17": "2001:660:4406:9a0:602:1:0:28", + "kavlan-18": "2001:660:4406:8a0:602:1:0:28", + "kavlan-2": "2001:660:4406:681:2:1:0:28", + "kavlan-20": "2001:660:4406:3a0:602:1:0:28", + "kavlan-21": "2001:660:4406:6a0:602:1:0:28", + "kavlan-3": "2001:660:4406:682:2:1:0:28", + "kavlan-4": "2001:660:4406:690:2:1:0:28", + "kavlan-5": "2001:660:4406:691:2:1:0:28", + "kavlan-6": "2001:660:4406:692:2:1:0:28", + "kavlan-7": "2001:660:4406:693:2:1:0:28", + "kavlan-8": "2001:660:4406:694:2:1:0:28", + "kavlan-9": "2001:660:4406:695:2:1:0:28" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.40", + "ip6": "2001:660:4406:600:2:1:0:28", + "kavlan": true, "mac": "24:6e:96:6a:4f:22", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-40-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/40", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json index a86faf6c3c460bc2ac1b027ce424759681742284..b0563fe53b622f8bcc2493b5a0c2d0838683dffe 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.41", "kavlan-8": "10.45.1.41", "kavlan-9": "10.45.65.41" + }, + "eth1": { + "kavlan-1": "192.168.194.41", + "kavlan-11": "10.7.241.141", + "kavlan-12": "10.11.241.141", + "kavlan-13": "10.15.241.141", + "kavlan-14": "10.19.241.141", + "kavlan-16": "10.27.241.141", + "kavlan-17": "10.31.241.141", + "kavlan-18": "10.35.241.141", + "kavlan-2": "192.168.210.41", + "kavlan-20": "10.43.241.141", + "kavlan-21": "10.47.241.141", + "kavlan-3": "192.168.226.41", + "kavlan-4": "10.44.2.41", + "kavlan-5": "10.44.66.41", + "kavlan-6": "10.44.130.41", + "kavlan-7": "10.44.194.41", + "kavlan-8": "10.45.2.41", + "kavlan-9": "10.45.66.41" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::29", "kavlan-8": "2001:660:4406:694:2::29", "kavlan-9": "2001:660:4406:695:2::29" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:29", + "kavlan-11": "2001:660:4406:1a0:602:1:0:29", + "kavlan-12": "2001:660:4406:2a0:602:1:0:29", + "kavlan-13": "2001:660:4406:4a0:602:1:0:29", + "kavlan-14": "2001:660:4406:5a0:602:1:0:29", + "kavlan-16": "2001:660:4406:7a0:602:1:0:29", + "kavlan-17": "2001:660:4406:9a0:602:1:0:29", + "kavlan-18": "2001:660:4406:8a0:602:1:0:29", + "kavlan-2": "2001:660:4406:681:2:1:0:29", + "kavlan-20": "2001:660:4406:3a0:602:1:0:29", + "kavlan-21": "2001:660:4406:6a0:602:1:0:29", + "kavlan-3": "2001:660:4406:682:2:1:0:29", + "kavlan-4": "2001:660:4406:690:2:1:0:29", + "kavlan-5": "2001:660:4406:691:2:1:0:29", + "kavlan-6": "2001:660:4406:692:2:1:0:29", + "kavlan-7": "2001:660:4406:693:2:1:0:29", + "kavlan-8": "2001:660:4406:694:2:1:0:29", + "kavlan-9": "2001:660:4406:695:2:1:0:29" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.41", + "ip6": "2001:660:4406:600:2:1:0:29", + "kavlan": true, "mac": "24:6e:96:6a:49:0a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-41-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/41", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json index a57b56391db88bcaa498d7af46bd5789943ea973..27dc2723bf1ef88218d0ab982fc689fa440c6b27 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.42", "kavlan-8": "10.45.1.42", "kavlan-9": "10.45.65.42" + }, + "eth1": { + "kavlan-1": "192.168.194.42", + "kavlan-11": "10.7.241.142", + "kavlan-12": "10.11.241.142", + "kavlan-13": "10.15.241.142", + "kavlan-14": "10.19.241.142", + "kavlan-16": "10.27.241.142", + "kavlan-17": "10.31.241.142", + "kavlan-18": "10.35.241.142", + "kavlan-2": "192.168.210.42", + "kavlan-20": "10.43.241.142", + "kavlan-21": "10.47.241.142", + "kavlan-3": "192.168.226.42", + "kavlan-4": "10.44.2.42", + "kavlan-5": "10.44.66.42", + "kavlan-6": "10.44.130.42", + "kavlan-7": "10.44.194.42", + "kavlan-8": "10.45.2.42", + "kavlan-9": "10.45.66.42" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2a", "kavlan-8": "2001:660:4406:694:2::2a", "kavlan-9": "2001:660:4406:695:2::2a" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2a", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2a", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2a", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2a", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2a", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2a", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2a", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2a", + "kavlan-2": "2001:660:4406:681:2:1:0:2a", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2a", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2a", + "kavlan-3": "2001:660:4406:682:2:1:0:2a", + "kavlan-4": "2001:660:4406:690:2:1:0:2a", + "kavlan-5": "2001:660:4406:691:2:1:0:2a", + "kavlan-6": "2001:660:4406:692:2:1:0:2a", + "kavlan-7": "2001:660:4406:693:2:1:0:2a", + "kavlan-8": "2001:660:4406:694:2:1:0:2a", + "kavlan-9": "2001:660:4406:695:2:1:0:2a" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.42", + "ip6": "2001:660:4406:600:2:1:0:2a", + "kavlan": true, "mac": "24:6e:96:6a:4c:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-42-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/42", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json index 9f3f038f5149db50c2f6fdf590bd2148e0fb495e..175ff23b067ed9c433dca68ce553a5bae2181e43 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.43", "kavlan-8": "10.45.1.43", "kavlan-9": "10.45.65.43" + }, + "eth1": { + "kavlan-1": "192.168.194.43", + "kavlan-11": "10.7.241.143", + "kavlan-12": "10.11.241.143", + "kavlan-13": "10.15.241.143", + "kavlan-14": "10.19.241.143", + "kavlan-16": "10.27.241.143", + "kavlan-17": "10.31.241.143", + "kavlan-18": "10.35.241.143", + "kavlan-2": "192.168.210.43", + "kavlan-20": "10.43.241.143", + "kavlan-21": "10.47.241.143", + "kavlan-3": "192.168.226.43", + "kavlan-4": "10.44.2.43", + "kavlan-5": "10.44.66.43", + "kavlan-6": "10.44.130.43", + "kavlan-7": "10.44.194.43", + "kavlan-8": "10.45.2.43", + "kavlan-9": "10.45.66.43" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2b", "kavlan-8": "2001:660:4406:694:2::2b", "kavlan-9": "2001:660:4406:695:2::2b" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2b", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2b", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2b", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2b", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2b", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2b", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2b", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2b", + "kavlan-2": "2001:660:4406:681:2:1:0:2b", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2b", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2b", + "kavlan-3": "2001:660:4406:682:2:1:0:2b", + "kavlan-4": "2001:660:4406:690:2:1:0:2b", + "kavlan-5": "2001:660:4406:691:2:1:0:2b", + "kavlan-6": "2001:660:4406:692:2:1:0:2b", + "kavlan-7": "2001:660:4406:693:2:1:0:2b", + "kavlan-8": "2001:660:4406:694:2:1:0:2b", + "kavlan-9": "2001:660:4406:695:2:1:0:2b" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.43", + "ip6": "2001:660:4406:600:2:1:0:2b", + "kavlan": true, "mac": "24:6e:96:6a:d0:82", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-43-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/43", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json index 5f7ff475ba9c8c33e837d691ffdc552563819796..7cafd4372f2be1c8a0be6584357170fbc77a9301 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.44", "kavlan-8": "10.45.1.44", "kavlan-9": "10.45.65.44" + }, + "eth1": { + "kavlan-1": "192.168.194.44", + "kavlan-11": "10.7.241.144", + "kavlan-12": "10.11.241.144", + "kavlan-13": "10.15.241.144", + "kavlan-14": "10.19.241.144", + "kavlan-16": "10.27.241.144", + "kavlan-17": "10.31.241.144", + "kavlan-18": "10.35.241.144", + "kavlan-2": "192.168.210.44", + "kavlan-20": "10.43.241.144", + "kavlan-21": "10.47.241.144", + "kavlan-3": "192.168.226.44", + "kavlan-4": "10.44.2.44", + "kavlan-5": "10.44.66.44", + "kavlan-6": "10.44.130.44", + "kavlan-7": "10.44.194.44", + "kavlan-8": "10.45.2.44", + "kavlan-9": "10.45.66.44" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2c", "kavlan-8": "2001:660:4406:694:2::2c", "kavlan-9": "2001:660:4406:695:2::2c" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2c", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2c", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2c", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2c", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2c", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2c", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2c", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2c", + "kavlan-2": "2001:660:4406:681:2:1:0:2c", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2c", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2c", + "kavlan-3": "2001:660:4406:682:2:1:0:2c", + "kavlan-4": "2001:660:4406:690:2:1:0:2c", + "kavlan-5": "2001:660:4406:691:2:1:0:2c", + "kavlan-6": "2001:660:4406:692:2:1:0:2c", + "kavlan-7": "2001:660:4406:693:2:1:0:2c", + "kavlan-8": "2001:660:4406:694:2:1:0:2c", + "kavlan-9": "2001:660:4406:695:2:1:0:2c" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.44", + "ip6": "2001:660:4406:600:2:1:0:2c", + "kavlan": true, "mac": "24:6e:96:6a:63:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-44-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/44", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json index c2ddaf60642d5592523283befe981645bf58e0d1..f755037db0198f113af02825f5ca192af7ab3ac7 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.45", "kavlan-8": "10.45.1.45", "kavlan-9": "10.45.65.45" + }, + "eth1": { + "kavlan-1": "192.168.194.45", + "kavlan-11": "10.7.241.145", + "kavlan-12": "10.11.241.145", + "kavlan-13": "10.15.241.145", + "kavlan-14": "10.19.241.145", + "kavlan-16": "10.27.241.145", + "kavlan-17": "10.31.241.145", + "kavlan-18": "10.35.241.145", + "kavlan-2": "192.168.210.45", + "kavlan-20": "10.43.241.145", + "kavlan-21": "10.47.241.145", + "kavlan-3": "192.168.226.45", + "kavlan-4": "10.44.2.45", + "kavlan-5": "10.44.66.45", + "kavlan-6": "10.44.130.45", + "kavlan-7": "10.44.194.45", + "kavlan-8": "10.45.2.45", + "kavlan-9": "10.45.66.45" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2d", "kavlan-8": "2001:660:4406:694:2::2d", "kavlan-9": "2001:660:4406:695:2::2d" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2d", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2d", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2d", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2d", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2d", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2d", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2d", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2d", + "kavlan-2": "2001:660:4406:681:2:1:0:2d", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2d", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2d", + "kavlan-3": "2001:660:4406:682:2:1:0:2d", + "kavlan-4": "2001:660:4406:690:2:1:0:2d", + "kavlan-5": "2001:660:4406:691:2:1:0:2d", + "kavlan-6": "2001:660:4406:692:2:1:0:2d", + "kavlan-7": "2001:660:4406:693:2:1:0:2d", + "kavlan-8": "2001:660:4406:694:2:1:0:2d", + "kavlan-9": "2001:660:4406:695:2:1:0:2d" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.45", + "ip6": "2001:660:4406:600:2:1:0:2d", + "kavlan": true, "mac": "24:6e:96:6a:47:42", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-45-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/45", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json index 600c9b55584d23168058e9b39319b8c7679bedd5..8575ccd241bc99003be740c727fc8d6ed56f766b 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.46", "kavlan-8": "10.45.1.46", "kavlan-9": "10.45.65.46" + }, + "eth1": { + "kavlan-1": "192.168.194.46", + "kavlan-11": "10.7.241.146", + "kavlan-12": "10.11.241.146", + "kavlan-13": "10.15.241.146", + "kavlan-14": "10.19.241.146", + "kavlan-16": "10.27.241.146", + "kavlan-17": "10.31.241.146", + "kavlan-18": "10.35.241.146", + "kavlan-2": "192.168.210.46", + "kavlan-20": "10.43.241.146", + "kavlan-21": "10.47.241.146", + "kavlan-3": "192.168.226.46", + "kavlan-4": "10.44.2.46", + "kavlan-5": "10.44.66.46", + "kavlan-6": "10.44.130.46", + "kavlan-7": "10.44.194.46", + "kavlan-8": "10.45.2.46", + "kavlan-9": "10.45.66.46" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2e", "kavlan-8": "2001:660:4406:694:2::2e", "kavlan-9": "2001:660:4406:695:2::2e" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2e", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2e", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2e", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2e", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2e", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2e", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2e", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2e", + "kavlan-2": "2001:660:4406:681:2:1:0:2e", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2e", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2e", + "kavlan-3": "2001:660:4406:682:2:1:0:2e", + "kavlan-4": "2001:660:4406:690:2:1:0:2e", + "kavlan-5": "2001:660:4406:691:2:1:0:2e", + "kavlan-6": "2001:660:4406:692:2:1:0:2e", + "kavlan-7": "2001:660:4406:693:2:1:0:2e", + "kavlan-8": "2001:660:4406:694:2:1:0:2e", + "kavlan-9": "2001:660:4406:695:2:1:0:2e" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.46", + "ip6": "2001:660:4406:600:2:1:0:2e", + "kavlan": true, "mac": "24:6e:96:6a:c9:aa", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-46-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/46", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json index c88a250a70e4dd96d8629f3d72d831effcef5fb0..6934cd1f4deabb85da83b50bb1c60e003306bda2 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.47", "kavlan-8": "10.45.1.47", "kavlan-9": "10.45.65.47" + }, + "eth1": { + "kavlan-1": "192.168.194.47", + "kavlan-11": "10.7.241.147", + "kavlan-12": "10.11.241.147", + "kavlan-13": "10.15.241.147", + "kavlan-14": "10.19.241.147", + "kavlan-16": "10.27.241.147", + "kavlan-17": "10.31.241.147", + "kavlan-18": "10.35.241.147", + "kavlan-2": "192.168.210.47", + "kavlan-20": "10.43.241.147", + "kavlan-21": "10.47.241.147", + "kavlan-3": "192.168.226.47", + "kavlan-4": "10.44.2.47", + "kavlan-5": "10.44.66.47", + "kavlan-6": "10.44.130.47", + "kavlan-7": "10.44.194.47", + "kavlan-8": "10.45.2.47", + "kavlan-9": "10.45.66.47" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::2f", "kavlan-8": "2001:660:4406:694:2::2f", "kavlan-9": "2001:660:4406:695:2::2f" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:2f", + "kavlan-11": "2001:660:4406:1a0:602:1:0:2f", + "kavlan-12": "2001:660:4406:2a0:602:1:0:2f", + "kavlan-13": "2001:660:4406:4a0:602:1:0:2f", + "kavlan-14": "2001:660:4406:5a0:602:1:0:2f", + "kavlan-16": "2001:660:4406:7a0:602:1:0:2f", + "kavlan-17": "2001:660:4406:9a0:602:1:0:2f", + "kavlan-18": "2001:660:4406:8a0:602:1:0:2f", + "kavlan-2": "2001:660:4406:681:2:1:0:2f", + "kavlan-20": "2001:660:4406:3a0:602:1:0:2f", + "kavlan-21": "2001:660:4406:6a0:602:1:0:2f", + "kavlan-3": "2001:660:4406:682:2:1:0:2f", + "kavlan-4": "2001:660:4406:690:2:1:0:2f", + "kavlan-5": "2001:660:4406:691:2:1:0:2f", + "kavlan-6": "2001:660:4406:692:2:1:0:2f", + "kavlan-7": "2001:660:4406:693:2:1:0:2f", + "kavlan-8": "2001:660:4406:694:2:1:0:2f", + "kavlan-9": "2001:660:4406:695:2:1:0:2f" } }, "main_memory": { @@ -142,18 +182,23 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.47", + "ip6": "2001:660:4406:600:2:1:0:2f", + "kavlan": true, "mac": "24:6e:96:6a:d1:ea", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-47-eth1.nantes.grid5000.fr", "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/47", "vendor": "Intel" }, { @@ -194,7 +239,7 @@ "device": "bmc", "enabled": true, "interface": "Ethernet", - "ip": "172.17.193.47", + "ip": "0.0.0.0", "kavlan": false, "mac": "50:9a:4c:a8:8d:9c", "management": true, diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json index 467c935c78903a6ba6c4a36c461ebb392cb822c4..81ee06b5aba2dba451eb94c84d0153dee5411793 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.48", "kavlan-8": "10.45.1.48", "kavlan-9": "10.45.65.48" + }, + "eth1": { + "kavlan-1": "192.168.194.48", + "kavlan-11": "10.7.241.148", + "kavlan-12": "10.11.241.148", + "kavlan-13": "10.15.241.148", + "kavlan-14": "10.19.241.148", + "kavlan-16": "10.27.241.148", + "kavlan-17": "10.31.241.148", + "kavlan-18": "10.35.241.148", + "kavlan-2": "192.168.210.48", + "kavlan-20": "10.43.241.148", + "kavlan-21": "10.47.241.148", + "kavlan-3": "192.168.226.48", + "kavlan-4": "10.44.2.48", + "kavlan-5": "10.44.66.48", + "kavlan-6": "10.44.130.48", + "kavlan-7": "10.44.194.48", + "kavlan-8": "10.45.2.48", + "kavlan-9": "10.45.66.48" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::30", "kavlan-8": "2001:660:4406:694:2::30", "kavlan-9": "2001:660:4406:695:2::30" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:30", + "kavlan-11": "2001:660:4406:1a0:602:1:0:30", + "kavlan-12": "2001:660:4406:2a0:602:1:0:30", + "kavlan-13": "2001:660:4406:4a0:602:1:0:30", + "kavlan-14": "2001:660:4406:5a0:602:1:0:30", + "kavlan-16": "2001:660:4406:7a0:602:1:0:30", + "kavlan-17": "2001:660:4406:9a0:602:1:0:30", + "kavlan-18": "2001:660:4406:8a0:602:1:0:30", + "kavlan-2": "2001:660:4406:681:2:1:0:30", + "kavlan-20": "2001:660:4406:3a0:602:1:0:30", + "kavlan-21": "2001:660:4406:6a0:602:1:0:30", + "kavlan-3": "2001:660:4406:682:2:1:0:30", + "kavlan-4": "2001:660:4406:690:2:1:0:30", + "kavlan-5": "2001:660:4406:691:2:1:0:30", + "kavlan-6": "2001:660:4406:692:2:1:0:30", + "kavlan-7": "2001:660:4406:693:2:1:0:30", + "kavlan-8": "2001:660:4406:694:2:1:0:30", + "kavlan-9": "2001:660:4406:695:2:1:0:30" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.48", + "ip6": "2001:660:4406:600:2:1:0:30", + "kavlan": true, "mac": "24:6e:96:6a:cf:52", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-48-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/48", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json index 56733e4b8fb6810422640b5da11f4675d18bde78..f40c2bd0713d0eb28e707520a0af34d0930bd6c1 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.5", "kavlan-8": "10.45.1.5", "kavlan-9": "10.45.65.5" + }, + "eth1": { + "kavlan-1": "192.168.194.5", + "kavlan-11": "10.7.241.105", + "kavlan-12": "10.11.241.105", + "kavlan-13": "10.15.241.105", + "kavlan-14": "10.19.241.105", + "kavlan-16": "10.27.241.105", + "kavlan-17": "10.31.241.105", + "kavlan-18": "10.35.241.105", + "kavlan-2": "192.168.210.5", + "kavlan-20": "10.43.241.105", + "kavlan-21": "10.47.241.105", + "kavlan-3": "192.168.226.5", + "kavlan-4": "10.44.2.5", + "kavlan-5": "10.44.66.5", + "kavlan-6": "10.44.130.5", + "kavlan-7": "10.44.194.5", + "kavlan-8": "10.45.2.5", + "kavlan-9": "10.45.66.5" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::5", "kavlan-8": "2001:660:4406:694:2::5", "kavlan-9": "2001:660:4406:695:2::5" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:5", + "kavlan-11": "2001:660:4406:1a0:602:1:0:5", + "kavlan-12": "2001:660:4406:2a0:602:1:0:5", + "kavlan-13": "2001:660:4406:4a0:602:1:0:5", + "kavlan-14": "2001:660:4406:5a0:602:1:0:5", + "kavlan-16": "2001:660:4406:7a0:602:1:0:5", + "kavlan-17": "2001:660:4406:9a0:602:1:0:5", + "kavlan-18": "2001:660:4406:8a0:602:1:0:5", + "kavlan-2": "2001:660:4406:681:2:1:0:5", + "kavlan-20": "2001:660:4406:3a0:602:1:0:5", + "kavlan-21": "2001:660:4406:6a0:602:1:0:5", + "kavlan-3": "2001:660:4406:682:2:1:0:5", + "kavlan-4": "2001:660:4406:690:2:1:0:5", + "kavlan-5": "2001:660:4406:691:2:1:0:5", + "kavlan-6": "2001:660:4406:692:2:1:0:5", + "kavlan-7": "2001:660:4406:693:2:1:0:5", + "kavlan-8": "2001:660:4406:694:2:1:0:5", + "kavlan-9": "2001:660:4406:695:2:1:0:5" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.5", + "ip6": "2001:660:4406:600:2:1:0:5", + "kavlan": true, "mac": "24:6e:96:6a:d3:2a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-5-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/5", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json index f66d059aea88fb869766ae24f9b931553f7dc327..7888a13dc802b06f1959d858f78c82a2ac491b2a 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.6", "kavlan-8": "10.45.1.6", "kavlan-9": "10.45.65.6" + }, + "eth1": { + "kavlan-1": "192.168.194.6", + "kavlan-11": "10.7.241.106", + "kavlan-12": "10.11.241.106", + "kavlan-13": "10.15.241.106", + "kavlan-14": "10.19.241.106", + "kavlan-16": "10.27.241.106", + "kavlan-17": "10.31.241.106", + "kavlan-18": "10.35.241.106", + "kavlan-2": "192.168.210.6", + "kavlan-20": "10.43.241.106", + "kavlan-21": "10.47.241.106", + "kavlan-3": "192.168.226.6", + "kavlan-4": "10.44.2.6", + "kavlan-5": "10.44.66.6", + "kavlan-6": "10.44.130.6", + "kavlan-7": "10.44.194.6", + "kavlan-8": "10.45.2.6", + "kavlan-9": "10.45.66.6" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::6", "kavlan-8": "2001:660:4406:694:2::6", "kavlan-9": "2001:660:4406:695:2::6" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:6", + "kavlan-11": "2001:660:4406:1a0:602:1:0:6", + "kavlan-12": "2001:660:4406:2a0:602:1:0:6", + "kavlan-13": "2001:660:4406:4a0:602:1:0:6", + "kavlan-14": "2001:660:4406:5a0:602:1:0:6", + "kavlan-16": "2001:660:4406:7a0:602:1:0:6", + "kavlan-17": "2001:660:4406:9a0:602:1:0:6", + "kavlan-18": "2001:660:4406:8a0:602:1:0:6", + "kavlan-2": "2001:660:4406:681:2:1:0:6", + "kavlan-20": "2001:660:4406:3a0:602:1:0:6", + "kavlan-21": "2001:660:4406:6a0:602:1:0:6", + "kavlan-3": "2001:660:4406:682:2:1:0:6", + "kavlan-4": "2001:660:4406:690:2:1:0:6", + "kavlan-5": "2001:660:4406:691:2:1:0:6", + "kavlan-6": "2001:660:4406:692:2:1:0:6", + "kavlan-7": "2001:660:4406:693:2:1:0:6", + "kavlan-8": "2001:660:4406:694:2:1:0:6", + "kavlan-9": "2001:660:4406:695:2:1:0:6" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.6", + "ip6": "2001:660:4406:600:2:1:0:6", + "kavlan": true, "mac": "24:6e:96:6a:d6:b2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-6-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/6", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json index 56f855d5e97063ef571fae470a504872e4a724f2..d08c3c1005cf043b28e86e5bb244261730c7834e 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.7", "kavlan-8": "10.45.1.7", "kavlan-9": "10.45.65.7" + }, + "eth1": { + "kavlan-1": "192.168.194.7", + "kavlan-11": "10.7.241.107", + "kavlan-12": "10.11.241.107", + "kavlan-13": "10.15.241.107", + "kavlan-14": "10.19.241.107", + "kavlan-16": "10.27.241.107", + "kavlan-17": "10.31.241.107", + "kavlan-18": "10.35.241.107", + "kavlan-2": "192.168.210.7", + "kavlan-20": "10.43.241.107", + "kavlan-21": "10.47.241.107", + "kavlan-3": "192.168.226.7", + "kavlan-4": "10.44.2.7", + "kavlan-5": "10.44.66.7", + "kavlan-6": "10.44.130.7", + "kavlan-7": "10.44.194.7", + "kavlan-8": "10.45.2.7", + "kavlan-9": "10.45.66.7" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::7", "kavlan-8": "2001:660:4406:694:2::7", "kavlan-9": "2001:660:4406:695:2::7" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:7", + "kavlan-11": "2001:660:4406:1a0:602:1:0:7", + "kavlan-12": "2001:660:4406:2a0:602:1:0:7", + "kavlan-13": "2001:660:4406:4a0:602:1:0:7", + "kavlan-14": "2001:660:4406:5a0:602:1:0:7", + "kavlan-16": "2001:660:4406:7a0:602:1:0:7", + "kavlan-17": "2001:660:4406:9a0:602:1:0:7", + "kavlan-18": "2001:660:4406:8a0:602:1:0:7", + "kavlan-2": "2001:660:4406:681:2:1:0:7", + "kavlan-20": "2001:660:4406:3a0:602:1:0:7", + "kavlan-21": "2001:660:4406:6a0:602:1:0:7", + "kavlan-3": "2001:660:4406:682:2:1:0:7", + "kavlan-4": "2001:660:4406:690:2:1:0:7", + "kavlan-5": "2001:660:4406:691:2:1:0:7", + "kavlan-6": "2001:660:4406:692:2:1:0:7", + "kavlan-7": "2001:660:4406:693:2:1:0:7", + "kavlan-8": "2001:660:4406:694:2:1:0:7", + "kavlan-9": "2001:660:4406:695:2:1:0:7" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.7", + "ip6": "2001:660:4406:600:2:1:0:7", + "kavlan": true, "mac": "24:6e:96:6a:4f:7a", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-7-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/7", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json index 32add3efa282a86c99362699b14f1bd66d0cf14a..58c530b1adadf57c284727f41e7af504a39c49d1 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.8", "kavlan-8": "10.45.1.8", "kavlan-9": "10.45.65.8" + }, + "eth1": { + "kavlan-1": "192.168.194.8", + "kavlan-11": "10.7.241.108", + "kavlan-12": "10.11.241.108", + "kavlan-13": "10.15.241.108", + "kavlan-14": "10.19.241.108", + "kavlan-16": "10.27.241.108", + "kavlan-17": "10.31.241.108", + "kavlan-18": "10.35.241.108", + "kavlan-2": "192.168.210.8", + "kavlan-20": "10.43.241.108", + "kavlan-21": "10.47.241.108", + "kavlan-3": "192.168.226.8", + "kavlan-4": "10.44.2.8", + "kavlan-5": "10.44.66.8", + "kavlan-6": "10.44.130.8", + "kavlan-7": "10.44.194.8", + "kavlan-8": "10.45.2.8", + "kavlan-9": "10.45.66.8" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::8", "kavlan-8": "2001:660:4406:694:2::8", "kavlan-9": "2001:660:4406:695:2::8" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:8", + "kavlan-11": "2001:660:4406:1a0:602:1:0:8", + "kavlan-12": "2001:660:4406:2a0:602:1:0:8", + "kavlan-13": "2001:660:4406:4a0:602:1:0:8", + "kavlan-14": "2001:660:4406:5a0:602:1:0:8", + "kavlan-16": "2001:660:4406:7a0:602:1:0:8", + "kavlan-17": "2001:660:4406:9a0:602:1:0:8", + "kavlan-18": "2001:660:4406:8a0:602:1:0:8", + "kavlan-2": "2001:660:4406:681:2:1:0:8", + "kavlan-20": "2001:660:4406:3a0:602:1:0:8", + "kavlan-21": "2001:660:4406:6a0:602:1:0:8", + "kavlan-3": "2001:660:4406:682:2:1:0:8", + "kavlan-4": "2001:660:4406:690:2:1:0:8", + "kavlan-5": "2001:660:4406:691:2:1:0:8", + "kavlan-6": "2001:660:4406:692:2:1:0:8", + "kavlan-7": "2001:660:4406:693:2:1:0:8", + "kavlan-8": "2001:660:4406:694:2:1:0:8", + "kavlan-9": "2001:660:4406:695:2:1:0:8" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.8", + "ip6": "2001:660:4406:600:2:1:0:8", + "kavlan": true, "mac": "24:6e:96:6a:c9:d2", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-8-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/8", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json index 1cc43eb8c962eed9f9d920046c9597149b4f60bb..09f8cdf95bbe3db07fd76fbf0d459e58da2f2591 100644 --- a/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json +++ b/data/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.json @@ -40,6 +40,26 @@ "kavlan-7": "10.44.193.9", "kavlan-8": "10.45.1.9", "kavlan-9": "10.45.65.9" + }, + "eth1": { + "kavlan-1": "192.168.194.9", + "kavlan-11": "10.7.241.109", + "kavlan-12": "10.11.241.109", + "kavlan-13": "10.15.241.109", + "kavlan-14": "10.19.241.109", + "kavlan-16": "10.27.241.109", + "kavlan-17": "10.31.241.109", + "kavlan-18": "10.35.241.109", + "kavlan-2": "192.168.210.9", + "kavlan-20": "10.43.241.109", + "kavlan-21": "10.47.241.109", + "kavlan-3": "192.168.226.9", + "kavlan-4": "10.44.2.9", + "kavlan-5": "10.44.66.9", + "kavlan-6": "10.44.130.9", + "kavlan-7": "10.44.194.9", + "kavlan-8": "10.45.2.9", + "kavlan-9": "10.45.66.9" } }, "kavlan6": { @@ -62,6 +82,26 @@ "kavlan-7": "2001:660:4406:693:2::9", "kavlan-8": "2001:660:4406:694:2::9", "kavlan-9": "2001:660:4406:695:2::9" + }, + "eth1": { + "kavlan-1": "2001:660:4406:680:2:1:0:9", + "kavlan-11": "2001:660:4406:1a0:602:1:0:9", + "kavlan-12": "2001:660:4406:2a0:602:1:0:9", + "kavlan-13": "2001:660:4406:4a0:602:1:0:9", + "kavlan-14": "2001:660:4406:5a0:602:1:0:9", + "kavlan-16": "2001:660:4406:7a0:602:1:0:9", + "kavlan-17": "2001:660:4406:9a0:602:1:0:9", + "kavlan-18": "2001:660:4406:8a0:602:1:0:9", + "kavlan-2": "2001:660:4406:681:2:1:0:9", + "kavlan-20": "2001:660:4406:3a0:602:1:0:9", + "kavlan-21": "2001:660:4406:6a0:602:1:0:9", + "kavlan-3": "2001:660:4406:682:2:1:0:9", + "kavlan-4": "2001:660:4406:690:2:1:0:9", + "kavlan-5": "2001:660:4406:691:2:1:0:9", + "kavlan-6": "2001:660:4406:692:2:1:0:9", + "kavlan-7": "2001:660:4406:693:2:1:0:9", + "kavlan-8": "2001:660:4406:694:2:1:0:9", + "kavlan-9": "2001:660:4406:695:2:1:0:9" } }, "main_memory": { @@ -142,18 +182,24 @@ { "device": "eth1", "driver": "ixgbe", - "enabled": false, + "enabled": true, "firmware_version": "0x8000095c, 19.5.12", "interface": "Ethernet", - "kavlan": false, + "ip": "172.16.194.9", + "ip6": "2001:660:4406:600:2:1:0:9", + "kavlan": true, "mac": "24:6e:96:6a:d7:02", "management": false, "model": "82599ES 10-Gigabit SFI/SFP+ Network Connection", - "mountable": false, + "mountable": true, "mounted": false, "name": "eno2", + "network_address": "ecotype-9-eth1.nantes.grid5000.fr", + "rate": 10000000000, "sriov": true, "sriov_totalvfs": 63, + "switch": "ecotype-prod2", + "switch_port": "TenGigabitEthernet 1/9", "vendor": "Intel" }, { diff --git a/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json b/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json index a1a2353ad02cb59a1754862d9312397fd2f4ee77..f2983243a0e425a1d22cae8bcdde9ff896b96239 100644 --- a/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json +++ b/data/grid5000/sites/nantes/network_equipments/ecotype-prod2.json @@ -20,100 +20,292 @@ { }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/1", + "uid": "ecotype-1" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/2", + "uid": "ecotype-2" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/3", + "uid": "ecotype-3" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/4", + "uid": "ecotype-4" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/5", + "uid": "ecotype-5" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/6", + "uid": "ecotype-6" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/7", + "uid": "ecotype-7" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/8", + "uid": "ecotype-8" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/9", + "uid": "ecotype-9" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/10", + "uid": "ecotype-10" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/11", + "uid": "ecotype-11" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/12", + "uid": "ecotype-12" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/13", + "uid": "ecotype-13" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/14", + "uid": "ecotype-14" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/15", + "uid": "ecotype-15" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/16", + "uid": "ecotype-16" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/17", + "uid": "ecotype-17" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/18", + "uid": "ecotype-18" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/19", + "uid": "ecotype-19" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/20", + "uid": "ecotype-20" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/21", + "uid": "ecotype-21" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/22", + "uid": "ecotype-22" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/23", + "uid": "ecotype-23" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/24", + "uid": "ecotype-24" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/25", + "uid": "ecotype-25" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/26", + "uid": "ecotype-26" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/27", + "uid": "ecotype-27" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/28", + "uid": "ecotype-28" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/29", + "uid": "ecotype-29" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/30", + "uid": "ecotype-30" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/31", + "uid": "ecotype-31" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/32", + "uid": "ecotype-32" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/33", + "uid": "ecotype-33" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/34", + "uid": "ecotype-34" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/35", + "uid": "ecotype-35" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/36", + "uid": "ecotype-36" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/37", + "uid": "ecotype-37" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/38", + "uid": "ecotype-38" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/39", + "uid": "ecotype-39" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/40", + "uid": "ecotype-40" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/41", + "uid": "ecotype-41" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/42", + "uid": "ecotype-42" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/43", + "uid": "ecotype-43" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/44", + "uid": "ecotype-44" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/45", + "uid": "ecotype-45" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/46", + "uid": "ecotype-46" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/47", + "uid": "ecotype-47" }, { + "kind": "node", + "port": "eth1", + "snmp_name": "TenGigabitEthernet 1/48", + "uid": "ecotype-48" }, { "kind": "channel", diff --git a/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml b/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml index dedfe3b2464de8e2b29dc7df32aa9937ad603753..2649f1ffd48cf6d15e588bc6077a918935151476 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/ecotype.yaml @@ -28,8 +28,8 @@ nodes: mountable: true eth1: mounted: false - enabled: false - mountable: false + enabled: true + mountable: true eth2: mounted: false enabled: false diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml index a681f6d37d734350976b665084a0e5ba2a47ef9f..0da08afc7f655549ea2b279e7f7cd4097226185e 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-10.yaml @@ -69,6 +69,7 @@ ecotype-10: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml index 6f38b08e0ceb54b9e53ee3bd5abf0fc7c6f3dfcf..6998bcf509ee0a087e3562bbce1dc5fc305fb5e6 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-11.yaml @@ -69,6 +69,7 @@ ecotype-11: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml index 2a4068f895d481bb42aaa763ee7e2d77ae319a62..d21844ad5b045d413c9ca0b80423fcd9aa55dcce 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-12.yaml @@ -69,6 +69,7 @@ ecotype-12: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml index a7ad0c13c4d1fc6022313a0aa4284079a3ce9da7..c0b7f5085cc7adfc4403ef8200a823991e9e741a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-13.yaml @@ -69,6 +69,7 @@ ecotype-13: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml index c2e75c1a33257a60e118869e9f11617f363d1284..73bcbaa3db4d22062526370a927428d7bba3b6e5 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-14.yaml @@ -69,6 +69,7 @@ ecotype-14: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml index fabeb8b5d69e8e21d039cb964bb32f5a657559a2..3143d72e891ee0fe48d826185f9a7db98858f026 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-15.yaml @@ -69,6 +69,7 @@ ecotype-15: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml index fc7b6e12741aed5b2de682709c43efd910400c4f..24f369f7b9a95834e4222459e5de2548fdd513da 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-16.yaml @@ -69,6 +69,7 @@ ecotype-16: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml index 66e62b59017e3a8cf38ff76ccd3200aaf6375f3c..bf632d8605de1bcc0f24accab6ab90e286cf574c 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-17.yaml @@ -69,6 +69,7 @@ ecotype-17: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml index fce9f08c63fd6c631a549ed392f2bfda6770763b..4a28e35f06835b755976037992af79a1675cc452 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-18.yaml @@ -69,6 +69,7 @@ ecotype-18: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml index 68b9f44b80b5984a30de9fc060a8284758a9dd70..1964f5e06ade0aa821951d558c296709e3c1a9c3 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-19.yaml @@ -69,6 +69,7 @@ ecotype-19: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml index bb5b636cdef7304854c599d4d26a7f861864b28f..be047fdc5b78775696082dc50a99013e875a4ff5 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-2.yaml @@ -69,6 +69,7 @@ ecotype-2: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml index 07c39b72020af7362167d5c4257905ded672e3e0..9a8300619b664d3a37964d830a75049acc6d6536 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-20.yaml @@ -69,6 +69,7 @@ ecotype-20: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml index 0f331ee73f726baed5c9af96b5231ba442279276..53532cc732e5d4b85f966679e4b6b42a6129f29a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-21.yaml @@ -69,6 +69,7 @@ ecotype-21: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml index 42ed17a8a7f3c91b9f7387ab097c5b1f955f76b6..c809a6a6c2b353b1b43c0053d7bc06f640f29aff 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-22.yaml @@ -69,6 +69,7 @@ ecotype-22: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml index 45beab8e454516ab456906fa28dd2f9985c69558..86ddd4dae76ea860b6c01b49994c1f6954707d9a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-23.yaml @@ -69,6 +69,7 @@ ecotype-23: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml index e3a0257803f1c13370c0471b48e1e1db6c146f79..79b439bfc96c0cac5298b930cc9c4aa32552e6d7 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-24.yaml @@ -69,6 +69,7 @@ ecotype-24: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml index 5e61db1971853cb79b692f87a2ae1185d178e883..1bc11730d6cc78df04ab219b7a9fdf1ad5769939 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-25.yaml @@ -69,6 +69,7 @@ ecotype-25: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml index 790aeef309d73677522787d7ece7ad0675b58f5c..c8dc9d7eb1744d2cfe7e5dd60ec3a8d80ff74869 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-26.yaml @@ -69,6 +69,7 @@ ecotype-26: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml index 3dd4b60dd177605609d9b4365374d22eda97c101..6ce521ba29ecedd33f70f19b28c2ca3dfe30de4a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-27.yaml @@ -69,6 +69,7 @@ ecotype-27: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml index abe54787b9774a7fa07a37c54983403349c69146..e6e4b55f8943d39c2e70e4ddb310ae4c1db35bda 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-28.yaml @@ -69,6 +69,7 @@ ecotype-28: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml index 4a850f0ae6a049cbf715b055a4166f5e637ee0b4..bfb6915ae8f6b97b64869eee139c2220a5df5273 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-29.yaml @@ -69,6 +69,7 @@ ecotype-29: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml index 3750cc5fc67ab810bf857a03ab03c9fcf8b2add2..2c5484c19eec9660e206508d0dc9bee151fb8e81 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-3.yaml @@ -69,6 +69,7 @@ ecotype-3: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml index 639c6bfa9f7cf5466cb53ac1c79967652b264459..650529e597d8ab6d8718bb25024dc2717e1e4e6f 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-30.yaml @@ -69,6 +69,7 @@ ecotype-30: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml index 0cc48946431f60c8ca93e704a8017adfb83bea0f..9ec98a779f4e713417a7c127cafb96814f8e2a85 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-31.yaml @@ -69,6 +69,7 @@ ecotype-31: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml index 21178a4326c54daf11a6367b586fb4671bd37914..47947476aa2ea1ef0e5ce2501b78e03e9810547a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-32.yaml @@ -69,6 +69,7 @@ ecotype-32: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml index 1075fc1f4b5bc24c1fdc89584073d35261cb23b3..a9e45d66492ce91abaa66aa7ae19cf8cb6f9b3ab 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-33.yaml @@ -69,6 +69,7 @@ ecotype-33: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml index da3ba5e72c5924232840b20340967cf23678fb12..7453939a65f2041404eb4b3ca98f56f3dc1c781c 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-34.yaml @@ -69,6 +69,7 @@ ecotype-34: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml index 25bc53cef4605a83ae432214633e6bb8e277dd35..fe8630c16554d5e54ec175732f7c3d2745f5a436 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-35.yaml @@ -69,6 +69,7 @@ ecotype-35: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml index 6129e527072641048330eeec901e9de5ebc31aaa..6ca0af044038ec38082005d458f7cdfc3548e1c9 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-36.yaml @@ -69,6 +69,7 @@ ecotype-36: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml index 0bc3db385c03fd9a08898f396394179cd68ba7d8..267fb2a255ffc7e1a1b490785e50d369d5795007 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-37.yaml @@ -69,6 +69,7 @@ ecotype-37: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml index 13810c7e2ff818305ef2b5fc010c106a4fbdcfd7..a3a42c3cdd03f1648a6702267ad711bc393105bf 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-38.yaml @@ -69,6 +69,7 @@ ecotype-38: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml index 6e7a118130dc32cecbb96aa533b000c18f106964..201a7402e22f1ca96be91293ecbe3f0cb0951361 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-39.yaml @@ -69,6 +69,7 @@ ecotype-39: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml index 603b5fc1e5d741272ed9ced783ba05276b862430..c389b9f77beed5bd00bc176d6cde368eaffe2521 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-4.yaml @@ -69,6 +69,7 @@ ecotype-4: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml index f7058bd4647bed046daefa00d2394ae8b67d95ff..d24af1129138b2667818c600295c646c9b04e327 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-40.yaml @@ -69,6 +69,7 @@ ecotype-40: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml index 2a226090084de6b00a85f3121228c0c8719573bc..8d148848b4ba3569a70e8357e575bc610d0f7883 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-41.yaml @@ -69,6 +69,7 @@ ecotype-41: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml index b01271eb91697c0f2ac76bd5f0b0ce80efc3b897..7addc34ff38c0ad81e9ca28b173f50efcfd2e6e3 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-42.yaml @@ -69,6 +69,7 @@ ecotype-42: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml index e175a61f59bd566ba3f250e7d33c00f32fd73ec8..067e24d2378b4d20649a842f4bc29eb0c0806e1d 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-43.yaml @@ -69,6 +69,7 @@ ecotype-43: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml index be71dced604c40f7883b99b0a7bb88112a37699e..11da2b00ff3673eadd0204c9b84f952b82793a3a 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-44.yaml @@ -69,6 +69,7 @@ ecotype-44: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml index f46ab0fe9d9d839d37ff8416d3041f38c228b33c..2eb933b5cb5c6073836b181d3acd33d90589c12f 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-45.yaml @@ -69,6 +69,7 @@ ecotype-45: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml index d2ff367f3bee128d1f83260d531299fe50a879f9..d1e63b3b5ed26e66b009f6c488a39b7dd6896b63 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-46.yaml @@ -69,6 +69,7 @@ ecotype-46: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml index 72503c67ec033a4d49e81fa0207c39fbbead2271..04324a857f2119911163695267e373332f6e5385 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-47.yaml @@ -45,7 +45,7 @@ ecotype-47: technology: dram network_adapters: bmc: - ip: 172.17.193.47 + ip: 0.0.0.0 mac: 50:9a:4c:a8:8d:9c management: true eth0: diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml index f4f311a0d86b9652bee50903b272afd213121928..54632ee607482b044675bffd020bcd97238aa601 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-48.yaml @@ -69,6 +69,7 @@ ecotype-48: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml index 54b790496d35c022119a8ad36f5e25718e479967..44329880518c37bce625f42737e1e0911fba7624 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-5.yaml @@ -69,6 +69,7 @@ ecotype-5: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml index 1a326cb50a42850d4f5425cb884d1f3411c1e5b6..822d8f6f0848b572238a67ca251fd11c7e46d1cc 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-6.yaml @@ -69,6 +69,7 @@ ecotype-6: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml index 9f2b8a4b5066485a6a47c6992ae0efe9f9c1aec7..5a19bbc0b62fb801e4a833eab48fff5390eaa12d 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-7.yaml @@ -69,6 +69,7 @@ ecotype-7: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml index 1a8f675a85aa568ea49f1d00a100c6c5529eb955..897ca0de319428f68643cb112a984b313f690c12 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-8.yaml @@ -69,6 +69,7 @@ ecotype-8: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml index d92297850181489049054a5172f16e076f1230c0..bac9ecfc5fafa4ddc1d07b16d9093d22f5c018a7 100644 --- a/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml +++ b/input/grid5000/sites/nantes/clusters/ecotype/nodes/ecotype-9.yaml @@ -69,6 +69,7 @@ ecotype-9: management: false model: 82599ES 10-Gigabit SFI/SFP+ Network Connection name: eno2 + rate: 10000000000 sriov: true sriov_totalvfs: 63 vendor: Intel diff --git a/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml b/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml index aa850c051eab440998179b370d3d9040bb7ecf4d..067281d2a5d2473079f35902129ade591388fbe0 100644 --- a/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml +++ b/input/grid5000/sites/nantes/networks/ecotype-prod2.yaml @@ -64,54 +64,54 @@ ecotype-prod2: kind: node rate: 10000000000 ports: - 1: - 2: - 3: - 4: - 5: - 6: - 8: - 7: - 9: - 10: - 11: - 12: - 13: - 14: - 15: - 16: - 17: - 18: - 19: - 20: - 21: - 22: - 23: - 24: - 25: - 26: - 27: - 28: - 29: - 30: - 31: - 32: - 33: - 34: - 35: - 36: - 37: - 38: - 39: - 40: - 41: - 42: - 43: - 44: - 45: - 46: - 47: - 48: + 1: ecotype-1-eth1 + 2: ecotype-2-eth1 + 3: ecotype-3-eth1 + 4: ecotype-4-eth1 + 5: ecotype-5-eth1 + 6: ecotype-6-eth1 + 8: ecotype-8-eth1 + 7: ecotype-7-eth1 + 9: ecotype-9-eth1 + 10: ecotype-10-eth1 + 11: ecotype-11-eth1 + 12: ecotype-12-eth1 + 13: ecotype-13-eth1 + 14: ecotype-14-eth1 + 15: ecotype-15-eth1 + 16: ecotype-16-eth1 + 17: ecotype-17-eth1 + 18: ecotype-18-eth1 + 19: ecotype-19-eth1 + 20: ecotype-20-eth1 + 21: ecotype-21-eth1 + 22: ecotype-22-eth1 + 23: ecotype-23-eth1 + 24: ecotype-24-eth1 + 25: ecotype-25-eth1 + 26: ecotype-26-eth1 + 27: ecotype-27-eth1 + 28: ecotype-28-eth1 + 29: ecotype-29-eth1 + 30: ecotype-30-eth1 + 31: ecotype-31-eth1 + 32: ecotype-32-eth1 + 33: ecotype-33-eth1 + 34: ecotype-34-eth1 + 35: ecotype-35-eth1 + 36: ecotype-36-eth1 + 37: ecotype-37-eth1 + 38: ecotype-38-eth1 + 39: ecotype-39-eth1 + 40: ecotype-40-eth1 + 41: ecotype-41-eth1 + 42: ecotype-42-eth1 + 43: ecotype-43-eth1 + 44: ecotype-44-eth1 + 45: ecotype-45-eth1 + 46: ecotype-46-eth1 + 47: ecotype-47-eth1 + 48: ecotype-48-eth1 49: uid: Port-channel 1 snmp_pattern: "fortyGigE %LINECARD%/%PORT%" diff --git a/lib/refrepo/valid/data/homogeneity.yaml.erb b/lib/refrepo/valid/data/homogeneity.yaml.erb index 000d320fe640df5cb9d51aa482f8c5d52cc26096..8f09716ff1969c3442860c3ac0bbf57d56b59187 100644 --- a/lib/refrepo/valid/data/homogeneity.yaml.erb +++ b/lib/refrepo/valid/data/homogeneity.yaml.erb @@ -288,6 +288,12 @@ nantes: - ~network_adapters.eth0.firmware_version - ~network_adapters.eth1.firmware_version - ~storage_devices.pci-0000:00:1f.2-ata-1.firmware_version + ecotype-2: + - +network_adapters.eth1.rate + ecotype-47: + - -network_adapters.eth1.rate + ecotype-48: + - +network_adapters.eth1.rate rennes: paradoxe-[2-3]: - ~storage_devices.pci-0000:47:00.0-scsi-0:2:1:0.firmware_version