From 025b85d332dffbdb9e4584a06a6da3cc100c7ca3 Mon Sep 17 00:00:00 2001
From: Baptiste Jonglez <baptiste.jonglez@imag.fr>
Date: Mon, 23 Nov 2020 13:10:56 +0100
Subject: [PATCH] [grenoble] [drac] Change network cabling

---
 .../grenoble/clusters/drac/nodes/drac-1.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-10.json | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-11.json | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-12.json | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-2.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-3.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-4.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-5.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-6.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-7.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-8.json  | 23 +++++++++----------
 .../grenoble/clusters/drac/nodes/drac-9.json  | 23 +++++++++----------
 input/grid5000/ipv4.yaml                      |  2 +-
 .../sites/grenoble/clusters/drac/drac.yaml    | 12 +++++-----
 .../grenoble/clusters/drac/nodes/drac-1.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-10.yaml |  3 +--
 .../grenoble/clusters/drac/nodes/drac-11.yaml |  3 +--
 .../grenoble/clusters/drac/nodes/drac-12.yaml |  3 +--
 .../grenoble/clusters/drac/nodes/drac-2.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-3.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-4.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-5.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-6.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-7.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-8.yaml  |  3 +--
 .../grenoble/clusters/drac/nodes/drac-9.yaml  |  3 +--
 26 files changed, 151 insertions(+), 175 deletions(-)

diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.json
index 9fb858213d..0a3d700700 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.1",
+      "ip6": "2001:660:4406:100:9:0::1",
       "kavlan": false,
       "mac": "98:be:94:68:1e:54",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-1.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.1",
-      "ip6": "2001:660:4406:100:9:0::1",
       "kavlan": false,
       "mac": "98:be:94:68:1e:57",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-1.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "13",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.json
index 78a4c9d53b..3a75e06b24 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.10",
+      "ip6": "2001:660:4406:100:9:0::a",
       "kavlan": false,
       "mac": "98:be:94:68:7a:44",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-10.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.10",
-      "ip6": "2001:660:4406:100:9:0::a",
       "kavlan": false,
       "mac": "98:be:94:68:7a:47",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-10.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "22",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.json
index 558031e584..691710939d 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.11",
+      "ip6": "2001:660:4406:100:9:0::b",
       "kavlan": false,
       "mac": "98:be:94:68:46:54",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-11.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.11",
-      "ip6": "2001:660:4406:100:9:0::b",
       "kavlan": false,
       "mac": "98:be:94:68:46:57",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-11.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "23",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.json
index 6fd0d41b59..95dc8244ab 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.12",
+      "ip6": "2001:660:4406:100:9:0::c",
       "kavlan": false,
       "mac": "98:be:94:68:7a:14",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-12.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.12",
-      "ip6": "2001:660:4406:100:9:0::c",
       "kavlan": false,
       "mac": "98:be:94:68:7a:17",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-12.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "24",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.json
index da1fcf5e64..ab26c7f4e7 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.2",
+      "ip6": "2001:660:4406:100:9:0::2",
       "kavlan": false,
       "mac": "98:be:94:68:72:34",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-2.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.2",
-      "ip6": "2001:660:4406:100:9:0::2",
       "kavlan": false,
       "mac": "98:be:94:68:72:37",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-2.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "14",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.json
index e3d5794211..4885749fb2 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.3",
+      "ip6": "2001:660:4406:100:9:0::3",
       "kavlan": false,
       "mac": "98:be:94:68:72:64",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-3.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.3",
-      "ip6": "2001:660:4406:100:9:0::3",
       "kavlan": false,
       "mac": "98:be:94:68:72:67",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-3.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "15",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.json
index df98491276..39dd6075ae 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.4",
+      "ip6": "2001:660:4406:100:9:0::4",
       "kavlan": false,
       "mac": "98:be:94:68:72:54",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-4.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.4",
-      "ip6": "2001:660:4406:100:9:0::4",
       "kavlan": false,
       "mac": "98:be:94:68:72:57",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-4.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "16",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.json
index 97d1564040..69134a7c59 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.5",
+      "ip6": "2001:660:4406:100:9:0::5",
       "kavlan": false,
       "mac": "98:be:94:68:48:cc",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-5.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.5",
-      "ip6": "2001:660:4406:100:9:0::5",
       "kavlan": false,
       "mac": "98:be:94:68:48:cf",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-5.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "17",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.json
index 74e2f07524..3dc6978d89 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.6",
+      "ip6": "2001:660:4406:100:9:0::6",
       "kavlan": false,
       "mac": "98:be:94:68:7a:50",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-6.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.6",
-      "ip6": "2001:660:4406:100:9:0::6",
       "kavlan": false,
       "mac": "98:be:94:68:7a:53",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-6.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "18",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.json
index 2b1de011f6..215bc81cee 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.7",
+      "ip6": "2001:660:4406:100:9:0::7",
       "kavlan": false,
       "mac": "98:be:94:68:80:14",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-7.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.7",
-      "ip6": "2001:660:4406:100:9:0::7",
       "kavlan": false,
       "mac": "98:be:94:68:80:17",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-7.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "19",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.json
index 2876ea5465..12a1f66f6f 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.8",
+      "ip6": "2001:660:4406:100:9:0::8",
       "kavlan": false,
       "mac": "98:be:94:68:7b:90",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-8.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.8",
-      "ip6": "2001:660:4406:100:9:0::8",
       "kavlan": false,
       "mac": "98:be:94:68:7b:93",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-8.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "20",
       "vendor": "Broadcom"
     },
     {
diff --git a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.json b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.json
index 6351d50d00..a9ca16abcb 100644
--- a/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.json
+++ b/data/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.json
@@ -63,19 +63,25 @@
   },
   "network_adapters": [
     {
+      "bridged": true,
       "device": "eth0",
       "driver": "bnx2x",
       "enabled": true,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
+      "ip": "172.16.24.9",
+      "ip6": "2001:660:4406:100:9:0::9",
       "kavlan": false,
       "mac": "98:be:94:68:75:c0",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": false,
-      "mounted": false,
+      "mountable": true,
+      "mounted": true,
       "name": "enP1p1s0f0",
+      "network_address": "drac-9.grenoble.grid5000.fr",
       "rate": 10000000000,
+      "switch": null,
+      "switch_port": null,
       "vendor": "Broadcom"
     },
     {
@@ -109,25 +115,18 @@
       "vendor": "Broadcom"
     },
     {
-      "bridged": true,
       "device": "eth3",
       "driver": "bnx2x",
-      "enabled": true,
+      "enabled": false,
       "firmware_version": "bc 7.10.4",
       "interface": "Ethernet",
-      "ip": "172.16.24.9",
-      "ip6": "2001:660:4406:100:9:0::9",
       "kavlan": false,
       "mac": "98:be:94:68:75:c3",
       "management": false,
       "model": "NetXtreme II BCM57800 1/10 Gigabit Ethernet",
-      "mountable": true,
-      "mounted": true,
+      "mountable": false,
+      "mounted": false,
       "name": "enP1p1s0f3",
-      "network_address": "drac-9.grenoble.grid5000.fr",
-      "rate": 1000000000,
-      "switch": "sw-ibm",
-      "switch_port": "21",
       "vendor": "Broadcom"
     },
     {
diff --git a/input/grid5000/ipv4.yaml b/input/grid5000/ipv4.yaml
index 002eec23d5..7a938baaea 100644
--- a/input/grid5000/ipv4.yaml
+++ b/input/grid5000/ipv4.yaml
@@ -14,7 +14,7 @@ ipv4:
       grenoble yeti eth0 0 0 3 0
       grenoble dahu eth0 0 0 4 0
       grenoble troll eth0 0 0 6 0
-      grenoble drac eth3 0 0 8 0
+      grenoble drac eth0 0 0 8 0
       lille chifflot eth0 0 0 4 0
       lille chifflot eth1 0 0 4 100
       lille chetemi eth0 0 0 5 0
diff --git a/input/grid5000/sites/grenoble/clusters/drac/drac.yaml b/input/grid5000/sites/grenoble/clusters/drac/drac.yaml
index ed515b4792..10323d3199 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/drac.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/drac.yaml
@@ -24,9 +24,10 @@ nodes:
         mountable: false
         mounted: false
       eth0:
+        bridged: true
         enabled: true
-        mountable: false
-        mounted: false
+        mountable: true
+        mounted: true
       eth1:
         enabled: false
         mountable: false
@@ -36,10 +37,9 @@ nodes:
         mountable: false
         mounted: false
       eth3:
-        bridged: true
-        enabled: true
-        mountable: true
-        mounted: true
+        enabled: false
+        mountable: false
+        mounted: false
       eth4:
         enabled: true
         mountable: false
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.yaml
index 640801e9c7..59aa42e3e0 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-1.yaml
@@ -59,6 +59,7 @@ drac-1:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.1
       mac: 98:be:94:68:1e:54
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-1:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.1
       mac: 98:be:94:68:1e:57
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.yaml
index d72bdfff25..933d4aa5a7 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-10.yaml
@@ -59,6 +59,7 @@ drac-10:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.10
       mac: 98:be:94:68:7a:44
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-10:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.10
       mac: 98:be:94:68:7a:47
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.yaml
index d35fa62e47..a6d5e0af5e 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-11.yaml
@@ -59,6 +59,7 @@ drac-11:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.11
       mac: 98:be:94:68:46:54
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-11:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.11
       mac: 98:be:94:68:46:57
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.yaml
index 328053a9ef..334c10013f 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-12.yaml
@@ -59,6 +59,7 @@ drac-12:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.12
       mac: 98:be:94:68:7a:14
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-12:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.12
       mac: 98:be:94:68:7a:17
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.yaml
index 87efb130a9..5c1b0948ef 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-2.yaml
@@ -59,6 +59,7 @@ drac-2:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.2
       mac: 98:be:94:68:72:34
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-2:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.2
       mac: 98:be:94:68:72:37
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.yaml
index c6510573a6..209765e6ad 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-3.yaml
@@ -59,6 +59,7 @@ drac-3:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.3
       mac: 98:be:94:68:72:64
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-3:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.3
       mac: 98:be:94:68:72:67
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.yaml
index ea74b2969a..d5603ec69a 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-4.yaml
@@ -59,6 +59,7 @@ drac-4:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.4
       mac: 98:be:94:68:72:54
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-4:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.4
       mac: 98:be:94:68:72:57
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.yaml
index c5d4ab6347..0ce7c3dea9 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-5.yaml
@@ -59,6 +59,7 @@ drac-5:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.5
       mac: 98:be:94:68:48:cc
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-5:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.5
       mac: 98:be:94:68:48:cf
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.yaml
index 9b485b1bc3..1e49186ecc 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-6.yaml
@@ -59,6 +59,7 @@ drac-6:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.6
       mac: 98:be:94:68:7a:50
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-6:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.6
       mac: 98:be:94:68:7a:53
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.yaml
index f93ce9d2bc..49902f9584 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-7.yaml
@@ -59,6 +59,7 @@ drac-7:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.7
       mac: 98:be:94:68:80:14
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-7:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.7
       mac: 98:be:94:68:80:17
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.yaml
index 66b901bb0c..104bb9bb6c 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-8.yaml
@@ -59,6 +59,7 @@ drac-8:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.8
       mac: 98:be:94:68:7b:90
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-8:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.8
       mac: 98:be:94:68:7b:93
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
diff --git a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.yaml b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.yaml
index 80416ffd02..89e5f1d201 100644
--- a/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.yaml
+++ b/input/grid5000/sites/grenoble/clusters/drac/nodes/drac-9.yaml
@@ -59,6 +59,7 @@ drac-9:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
+      ip: 172.16.24.9
       mac: 98:be:94:68:75:c0
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
@@ -87,12 +88,10 @@ drac-9:
       driver: bnx2x
       firmware_version: bc 7.10.4
       interface: Ethernet
-      ip: 172.16.24.9
       mac: 98:be:94:68:75:c3
       management: false
       model: NetXtreme II BCM57800 1/10 Gigabit Ethernet
       name: enP1p1s0f3
-      rate: 1000000000
       vendor: Broadcom
     eth4:
       driver: tg3
-- 
GitLab