diff --git a/data/grid5000/sites/nancy/clusters/gruss/gruss.json b/data/grid5000/sites/nancy/clusters/gruss/gruss.json new file mode 100644 index 0000000000000000000000000000000000000000..04bd39e3e1abe335bc0b331215a79f80a83aa42b --- /dev/null +++ b/data/grid5000/sites/nancy/clusters/gruss/gruss.json @@ -0,0 +1,15 @@ +{ + "created_at": "Thu, 26 Aug 2021 00:00:00 GMT", + "exotic": false, + "kavlan": false, + "metrics": [ + + ], + "model": "Dell PowerEdge R7525", + "queues": [ + "admin", + "testing" + ], + "type": "cluster", + "uid": "gruss" +} \ No newline at end of file diff --git a/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.json b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.json new file mode 100644 index 0000000000000000000000000000000000000000..46810cb0613da1ac39f26c826a4fcc76ba81a9ea --- /dev/null +++ b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.json @@ -0,0 +1,171 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 96, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "04/08/2021", + "vendor": "Dell Inc.", + "version": "2.2.5" + }, + "bmc_version": "5.00.00.00", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "2JRQQF3" + }, + "exotic": false, + "main_memory": { + "ram_size": 274877906944 + }, + "network_adapters": [ + { + "device": "eth0", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.8 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:5f:54", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth1", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.8 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:5f:55", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno2", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth2", + "driver": "mlx5_core", + "enabled": true, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "ip": "172.16.69.1", + "ip6": "2001:660:4406:500:6::1", + "kavlan": false, + "mac": "b8:ce:f6:2b:30:5c", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "gruss-1.nancy.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "sgruss", + "switch_port": "ethernet1/1/1", + "vendor": "Mellanox Technologies" + }, + { + "device": "eth3", + "driver": "mlx5_core", + "enabled": false, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "kavlan": false, + "mac": "b8:ce:f6:2b:30:5d", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Mellanox Technologies" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.69.1", + "kavlan": false, + "mac": "b0:7b:25:da:e2:b8", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "gruss-1-bmc.nancy.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": true, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 19200000000, + "node_flops": 921600000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2400000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2021092900", + "standard-environment": "debian10-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x62cea7f0adc4360028698cd43d496b46", + "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.14, + "id": "disk0", + "interface": "SAS", + "model": "PERC H345 Front", + "size": 1919716163584, + "storage": "SSD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 86400, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "gruss-1" +} \ No newline at end of file diff --git a/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.json b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.json new file mode 100644 index 0000000000000000000000000000000000000000..058ef78e8475f7568cf621112ed6739b374515cd --- /dev/null +++ b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.json @@ -0,0 +1,171 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 96, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "04/08/2021", + "vendor": "Dell Inc.", + "version": "2.2.5" + }, + "bmc_version": "5.00.00.00", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "2YTZWF3" + }, + "exotic": false, + "main_memory": { + "ram_size": 274877906944 + }, + "network_adapters": [ + { + "device": "eth0", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:b9:78", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth1", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:b9:79", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno2", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth2", + "driver": "mlx5_core", + "enabled": true, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "ip": "172.16.69.2", + "ip6": "2001:660:4406:500:6::2", + "kavlan": false, + "mac": "b8:ce:f6:33:52:86", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "gruss-2.nancy.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "sgruss", + "switch_port": "ethernet1/1/2", + "vendor": "Mellanox Technologies" + }, + { + "device": "eth3", + "driver": "mlx5_core", + "enabled": false, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "kavlan": false, + "mac": "b8:ce:f6:33:52:87", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Mellanox Technologies" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.69.2", + "kavlan": false, + "mac": "b0:7b:25:df:dd:08", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "gruss-2-bmc.nancy.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": true, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 19200000000, + "node_flops": 921600000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2400000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2021092900", + "standard-environment": "debian10-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x62cea7f0af7db200287f753db9890f33", + "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.14, + "id": "disk0", + "interface": "SAS", + "model": "PERC H345 Front", + "size": 1919716163584, + "storage": "SSD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 86400, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "gruss-2" +} \ No newline at end of file diff --git a/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.json b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.json new file mode 100644 index 0000000000000000000000000000000000000000..70ea5129116f34dec0b70020a048380a7c871877 --- /dev/null +++ b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.json @@ -0,0 +1,183 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 96, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "04/08/2021", + "vendor": "Dell Inc.", + "version": "2.2.5" + }, + "bmc_version": "5.00.00.00", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "1ZBX2G3" + }, + "exotic": false, + "main_memory": { + "ram_size": 274877906944 + }, + "network_adapters": [ + { + "device": "eth0", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:b8:e6", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth1", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:b8:e7", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno2", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth2", + "driver": "mlx5_core", + "enabled": true, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "ip": "172.16.69.3", + "ip6": "2001:660:4406:500:6::3", + "kavlan": false, + "mac": "b8:ce:f6:38:3b:e2", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "gruss-3.nancy.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "sgruss", + "switch_port": "ethernet1/1/3", + "vendor": "Mellanox Technologies" + }, + { + "device": "eth3", + "driver": "mlx5_core", + "enabled": false, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "kavlan": false, + "mac": "b8:ce:f6:38:3b:e3", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Mellanox Technologies" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.69.3", + "kavlan": false, + "mac": "b0:7b:25:df:db:a0", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "gruss-3-bmc.nancy.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": true, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 19200000000, + "node_flops": 921600000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2400000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2021092900", + "standard-environment": "debian10-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x62cea7f0bb1f3300288affd7b81eae16", + "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.14, + "id": "disk0", + "interface": "SAS", + "model": "PERC H345 Front", + "size": 1919716163584, + "storage": "SSD", + "vendor": "Dell" + }, + { + "by_id": "", + "by_path": "/dev/disk/by-path/pci-0000:02:00.0-ata-1", + "device": "sdb", + "firmware_version": "MV.R00-0", + "id": "disk1", + "interface": "NVME", + "model": "DELLBOSS VD", + "size": 480036847616, + "storage": "HDD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 172800, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "gruss-3" +} \ No newline at end of file diff --git a/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.json b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.json new file mode 100644 index 0000000000000000000000000000000000000000..ca1a4e8578c33d426835801c28c5d5bb581af028 --- /dev/null +++ b/data/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.json @@ -0,0 +1,183 @@ +{ + "architecture": { + "cpu_core_numbering": "contiguous", + "nb_cores": 48, + "nb_procs": 2, + "nb_threads": 96, + "platform_type": "x86_64" + }, + "bios": { + "release_date": "04/08/2021", + "vendor": "Dell Inc.", + "version": "2.2.5" + }, + "bmc_version": "5.00.00.00", + "chassis": { + "manufacturer": "Dell Inc.", + "name": "PowerEdge R7525", + "serial": "JYBX2G3" + }, + "exotic": false, + "main_memory": { + "ram_size": 274877906944 + }, + "network_adapters": [ + { + "device": "eth0", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:9b:ce", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno1", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth1", + "driver": "tg3", + "enabled": false, + "firmware_version": "FFV21.80.9 bc 5720-v1.39", + "interface": "Ethernet", + "kavlan": false, + "mac": "b0:7b:25:d4:9b:cf", + "management": false, + "model": "NetXtreme BCM5720 Gigabit Ethernet PCIe", + "mountable": false, + "mounted": false, + "name": "eno2", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Broadcom" + }, + { + "device": "eth2", + "driver": "mlx5_core", + "enabled": true, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "ip": "172.16.69.4", + "ip6": "2001:660:4406:500:6::4", + "kavlan": false, + "mac": "b8:ce:f6:38:3e:9a", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": true, + "mounted": true, + "name": "eno33", + "network_address": "gruss-4.nancy.grid5000.fr", + "rate": 25000000000, + "sriov": false, + "sriov_totalvfs": 0, + "switch": "sgruss", + "switch_port": "ethernet1/1/4", + "vendor": "Mellanox Technologies" + }, + { + "device": "eth3", + "driver": "mlx5_core", + "enabled": false, + "firmware_version": "16.28.4512 (DEL0000000016)", + "interface": "Ethernet", + "kavlan": false, + "mac": "b8:ce:f6:38:3e:9b", + "management": false, + "model": "MT27800 Family [ConnectX-5]", + "mountable": false, + "mounted": false, + "name": "eno34", + "sriov": false, + "sriov_totalvfs": 0, + "vendor": "Mellanox Technologies" + }, + { + "device": "bmc", + "enabled": true, + "interface": "Ethernet", + "ip": "172.17.69.4", + "kavlan": false, + "mac": "b0:7b:25:df:e0:ec", + "management": true, + "mountable": false, + "mounted": false, + "network_address": "gruss-4-bmc.nancy.grid5000.fr" + } + ], + "operating_system": { + "cstate_driver": "acpi_idle", + "cstate_governor": "menu", + "ht_enabled": true, + "pstate_driver": "acpi-cpufreq", + "pstate_governor": "performance", + "turboboost_enabled": true + }, + "performance": { + "core_flops": 19200000000, + "node_flops": 921600000000 + }, + "processor": { + "cache_l1": null, + "cache_l1d": 32768, + "cache_l1i": 32768, + "cache_l2": 524288, + "cache_l3": 16777216, + "clock_speed": 2400000000, + "ht_capable": true, + "instruction_set": "x86-64", + "microarchitecture": "Zen", + "microcode": "0x830104d", + "model": "AMD EPYC", + "other_description": "AMD EPYC 7352 24-Core Processor", + "vendor": "AMD", + "version": 7352 + }, + "software": { + "forced-deployment-timestamp": 202007300948, + "postinstall-version": "1.2021092900", + "standard-environment": "debian10-x64-std" + }, + "storage_devices": [ + { + "by_id": "/dev/disk/by-id/wwn-0x62cea7f0bb1f3b00288b02e9b3a78760", + "by_path": "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0", + "device": "sda", + "firmware_version": 5.14, + "id": "disk0", + "interface": "SAS", + "model": "PERC H345 Front", + "size": 1919716163584, + "storage": "SSD", + "vendor": "Dell" + }, + { + "by_id": "", + "by_path": "/dev/disk/by-path/pci-0000:02:00.0-ata-1", + "device": "sdb", + "firmware_version": "MV.R00-0", + "id": "disk1", + "interface": "NVME", + "model": "DELLBOSS VD", + "size": 480036847616, + "storage": "HDD", + "vendor": "Dell" + } + ], + "supported_job_types": { + "besteffort": true, + "deploy": true, + "max_walltime": 604800, + "queues": [ + "admin", + "testing" + ], + "virtual": "amd-v" + }, + "type": "node", + "uid": "gruss-4" +} \ No newline at end of file diff --git a/data/grid5000/sites/nancy/network_equipments/sgruss.json b/data/grid5000/sites/nancy/network_equipments/sgruss.json new file mode 100644 index 0000000000000000000000000000000000000000..e508281b9d8f79f2bd6d688d42620b9425abe689 --- /dev/null +++ b/data/grid5000/sites/nancy/network_equipments/sgruss.json @@ -0,0 +1,109 @@ +{ + "backplane_bps": 2160000000000, + "channels": { + "port-channel1": { + "kind": "router", + "port": "port-channel5", + "rate": 800000000000, + "uid": "gw" + } + }, + "ip": "172.17.79.212", + "kind": "switch", + "linecards": [ + { + }, + { + "kavlan_pattern": "ethernet1/%LINECARD%/%PORT%", + "kind": "node", + "ports": [ + { + }, + { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/1", + "uid": "gruss-1" + }, + { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/2", + "uid": "gruss-2" + }, + { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/3", + "uid": "gruss-3" + }, + { + "kind": "node", + "port": "eth0", + "snmp_name": "ethernet1/1/4", + "uid": "gruss-4" + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + }, + { + "kind": "channel", + "rate": 25000000000, + "snmp_name": "ethernet1/1/25:1", + "uid": "port-channel1" + }, + { + "kind": "channel", + "rate": 25000000000, + "snmp_name": "ethernet1/1/26:1", + "uid": "port-channel1" + } + ], + "rate": 25000000000, + "snmp_pattern": "ethernet1/%LINECARD%/%PORT%" + } + ], + "model": "Dell S5224F-ON", + "site": "nancy", + "snmp_community": "public", + "type": "network_equipment", + "uid": "sgruss", + "warranty": "2026-08-02" +} \ No newline at end of file diff --git a/input/grid5000/disks.yaml b/input/grid5000/disks.yaml index c85584da27fc091bc818a0b74e4092f76e2a3eee..2558f6a1d2a2f5db93d4dc3f2e5d9264d164bb9e 100644 --- a/input/grid5000/disks.yaml +++ b/input/grid5000/disks.yaml @@ -11,6 +11,7 @@ disk_vendor_model_mapping: - PERC H730 Mini - PERC H730P Adp - PERC H345 Front + - DELLBOSS VD Unknown: - unknown diff --git a/input/grid5000/ipv4.yaml b/input/grid5000/ipv4.yaml index 5a29a027beb8c0cc87c77d7761ae5dfd6d86b6be..c1aaac921c1185189198d351120be279455c3a90 100644 --- a/input/grid5000/ipv4.yaml +++ b/input/grid5000/ipv4.yaml @@ -56,6 +56,7 @@ ipv4: nancy grue eth0 0 0 13 0 nancy grappe eth0 0 0 14 0 nancy grouille eth2 0 0 15 0 + nancy gruss eth2 0 0 5 0 nantes econome eth0 0 0 0 0 nantes ecotype eth0 0 0 1 0 nantes ecotype eth1 0 0 2 0 diff --git a/input/grid5000/sites/nancy/clusters/gruss/gruss.yaml b/input/grid5000/sites/nancy/clusters/gruss/gruss.yaml new file mode 100644 index 0000000000000000000000000000000000000000..827f718f35e7ab514e260eccf591cb06659a4d82 --- /dev/null +++ b/input/grid5000/sites/nancy/clusters/gruss/gruss.yaml @@ -0,0 +1,55 @@ +model: Dell PowerEdge R7525 +created_at: 2021-08-26 +kavlan: false +exotic: false +queues: +- admin +- testing +nodes: + gruss-[3-4]: + storage_devices: + sdb: + interface: NVME + gruss-[1-4]: + supported_job_types: + deploy: true + besteffort: true + software: + standard-environment: debian10-x64-std + processor: + microarchitecture: Zen + clock_speed: 2400000000 + network_adapters: + bmc: + interface: Ethernet + enabled: true + mountable: false + mounted: false + eth0: + enabled: false + mountable: false + mounted: false + eth1: + enabled: false + mountable: false + mounted: false + eth2: + enabled: true + mountable: true + mounted: true + eth3: + enabled: false + mountable: false + mounted: false + storage_devices: + sda: + interface: SAS + gruss-[1-2]: + supported_job_types: + max_walltime: 86400 + gruss-3: + supported_job_types: + max_walltime: 172800 + gruss-[4-]: + supported_job_types: + max_walltime: 604800 diff --git a/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.yaml b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.yaml new file mode 100644 index 0000000000000000000000000000000000000000..b52e3bcf6e237c61f2053a52911aadc4cad9c82b --- /dev/null +++ b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-1.yaml @@ -0,0 +1,101 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +gruss-1: + architecture: + cpu_core_numbering: contiguous + nb_cores: 48 + nb_procs: 2 + nb_threads: 96 + platform_type: x86_64 + bios: + release_date: 04/08/2021 + vendor: Dell Inc. + version: 2.2.5 + bmc_version: 5.00.00.00 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: 2JRQQF3 + main_memory: + ram_size: 274877906944 + network_adapters: + bmc: + ip: 172.17.69.1 + mac: b0:7b:25:da:e2:b8 + management: true + eth0: + driver: tg3 + firmware_version: FFV21.80.8 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:5f:54 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno1 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth1: + driver: tg3 + firmware_version: FFV21.80.8 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:5f:55 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno2 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth2: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + ip: 172.16.69.1 + mac: b8:ce:f6:2b:30:5c + management: false + model: MT27800 Family [ConnectX-5] + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + eth3: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + mac: b8:ce:f6:2b:30:5d + management: false + model: MT27800 Family [ConnectX-5] + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: true + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + sda: + by_id: "/dev/disk/by-id/wwn-0x62cea7f0adc4360028698cd43d496b46" + by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0" + firmware_version: 5.14 + id: disk0 + model: PERC H345 Front + size: 1919716163584 + storage: SSD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.yaml b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.yaml new file mode 100644 index 0000000000000000000000000000000000000000..85546666b980b0e1564f6918ec87907ce6460831 --- /dev/null +++ b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-2.yaml @@ -0,0 +1,101 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +gruss-2: + architecture: + cpu_core_numbering: contiguous + nb_cores: 48 + nb_procs: 2 + nb_threads: 96 + platform_type: x86_64 + bios: + release_date: 04/08/2021 + vendor: Dell Inc. + version: 2.2.5 + bmc_version: 5.00.00.00 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: 2YTZWF3 + main_memory: + ram_size: 274877906944 + network_adapters: + bmc: + ip: 172.17.69.2 + mac: b0:7b:25:df:dd:08 + management: true + eth0: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:b9:78 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno1 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth1: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:b9:79 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno2 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth2: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + ip: 172.16.69.2 + mac: b8:ce:f6:33:52:86 + management: false + model: MT27800 Family [ConnectX-5] + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + eth3: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + mac: b8:ce:f6:33:52:87 + management: false + model: MT27800 Family [ConnectX-5] + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: true + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + sda: + by_id: "/dev/disk/by-id/wwn-0x62cea7f0af7db200287f753db9890f33" + by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0" + firmware_version: 5.14 + id: disk0 + model: PERC H345 Front + size: 1919716163584 + storage: SSD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.yaml b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.yaml new file mode 100644 index 0000000000000000000000000000000000000000..f078f665a3fa112153a80d0663b9eb9aaa812ec5 --- /dev/null +++ b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-3.yaml @@ -0,0 +1,108 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +gruss-3: + architecture: + cpu_core_numbering: contiguous + nb_cores: 48 + nb_procs: 2 + nb_threads: 96 + platform_type: x86_64 + bios: + release_date: 04/08/2021 + vendor: Dell Inc. + version: 2.2.5 + bmc_version: 5.00.00.00 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: 1ZBX2G3 + main_memory: + ram_size: 274877906944 + network_adapters: + bmc: + ip: 172.17.69.3 + mac: b0:7b:25:df:db:a0 + management: true + eth0: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:b8:e6 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno1 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth1: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:b8:e7 + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno2 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth2: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + ip: 172.16.69.3 + mac: b8:ce:f6:38:3b:e2 + management: false + model: MT27800 Family [ConnectX-5] + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + eth3: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + mac: b8:ce:f6:38:3b:e3 + management: false + model: MT27800 Family [ConnectX-5] + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: true + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + sda: + by_id: "/dev/disk/by-id/wwn-0x62cea7f0bb1f3300288affd7b81eae16" + by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0" + firmware_version: 5.14 + id: disk0 + model: PERC H345 Front + size: 1919716163584 + storage: SSD + sdb: + by_path: "/dev/disk/by-path/pci-0000:02:00.0-ata-1" + firmware_version: MV.R00-0 + id: disk1 + model: DELLBOSS VD + size: 480036847616 + storage: HDD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.yaml b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.yaml new file mode 100644 index 0000000000000000000000000000000000000000..24100ad4fac3aff4fc0de8ea91a79f4c3229c2e9 --- /dev/null +++ b/input/grid5000/sites/nancy/clusters/gruss/nodes/gruss-4.yaml @@ -0,0 +1,108 @@ +# Generated by g5k-checks (g5k-checks -m api) +--- +gruss-4: + architecture: + cpu_core_numbering: contiguous + nb_cores: 48 + nb_procs: 2 + nb_threads: 96 + platform_type: x86_64 + bios: + release_date: 04/08/2021 + vendor: Dell Inc. + version: 2.2.5 + bmc_version: 5.00.00.00 + chassis: + manufacturer: Dell Inc. + name: PowerEdge R7525 + serial: JYBX2G3 + main_memory: + ram_size: 274877906944 + network_adapters: + bmc: + ip: 172.17.69.4 + mac: b0:7b:25:df:e0:ec + management: true + eth0: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:9b:ce + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno1 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth1: + driver: tg3 + firmware_version: FFV21.80.9 bc 5720-v1.39 + interface: Ethernet + mac: b0:7b:25:d4:9b:cf + management: false + model: NetXtreme BCM5720 Gigabit Ethernet PCIe + name: eno2 + sriov: false + sriov_totalvfs: 0 + vendor: Broadcom + eth2: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + ip: 172.16.69.4 + mac: b8:ce:f6:38:3e:9a + management: false + model: MT27800 Family [ConnectX-5] + name: eno33 + rate: 25000000000 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + eth3: + driver: mlx5_core + firmware_version: 16.28.4512 (DEL0000000016) + interface: Ethernet + mac: b8:ce:f6:38:3e:9b + management: false + model: MT27800 Family [ConnectX-5] + name: eno34 + sriov: false + sriov_totalvfs: 0 + vendor: Mellanox Technologies + operating_system: + cstate_driver: acpi_idle + cstate_governor: menu + ht_enabled: true + pstate_driver: acpi-cpufreq + pstate_governor: performance + turboboost_enabled: true + processor: + cache_l1d: 32768 + cache_l1i: 32768 + cache_l2: 524288 + cache_l3: 16777216 + ht_capable: true + instruction_set: x86-64 + microcode: '0x830104d' + model: AMD EPYC + other_description: AMD EPYC 7352 24-Core Processor + vendor: AMD + version: 7352 + storage_devices: + sda: + by_id: "/dev/disk/by-id/wwn-0x62cea7f0bb1f3b00288b02e9b3a78760" + by_path: "/dev/disk/by-path/pci-0000:01:00.0-scsi-0:2:0:0" + firmware_version: 5.14 + id: disk0 + model: PERC H345 Front + size: 1919716163584 + storage: SSD + sdb: + by_path: "/dev/disk/by-path/pci-0000:02:00.0-ata-1" + firmware_version: MV.R00-0 + id: disk1 + model: DELLBOSS VD + size: 480036847616 + storage: HDD + supported_job_types: + virtual: amd-v diff --git a/input/grid5000/sites/nancy/networks/sgruss.yaml b/input/grid5000/sites/nancy/networks/sgruss.yaml new file mode 100644 index 0000000000000000000000000000000000000000..b9c46d65e600971733c6b8b0846a6a839700b6e8 --- /dev/null +++ b/input/grid5000/sites/nancy/networks/sgruss.yaml @@ -0,0 +1,42 @@ +--- +sgruss: + model: Dell S5224F-ON + warranty: "2026-08-02" + kind: switch + site: nancy + snmp_community: public + ip: 172.17.79.212 + backplane_bps: 2160000000000 + linecards: + 1: + snmp_pattern: "ethernet1/%LINECARD%/%PORT%" + kavlan_pattern: "ethernet1/%LINECARD%/%PORT%" + kind: node + rate: 25000000000 + ports: + 1: + uid: gruss-1 + 2: + uid: gruss-2 + 3: + uid: gruss-3 + 4: + uid: gruss-4 + 25: + snmp_pattern: "ethernet1/%LINECARD%/%PORT%:1" + kind: node + rate: 25000000000 + uid: port-channel1 + kind: channel + 26: + snmp_pattern: "ethernet1/%LINECARD%/%PORT%:1" + kind: node + rate: 25000000000 + uid: port-channel1 + kind: channel + channels: + port-channel1: + port: port-channel5 + uid: gw + kind: router + rate: 800000000000 diff --git a/lib/refrepo/net_names_mapping.yaml b/lib/refrepo/net_names_mapping.yaml index d6d68f1896b4b5aa092c9da6ca1199edbbb1d9fa..97f0d21cc49a418bde5cd64c2365311b6a430a38 100644 --- a/lib/refrepo/net_names_mapping.yaml +++ b/lib/refrepo/net_names_mapping.yaml @@ -125,6 +125,11 @@ grue: grvingt: enp24s0f0: eth0 enp24s0f1: eth1 +gruss: + eno1: eth0 + eno2: eth1 + eno33: eth2 + eno34: eth3 hercule: eno1: eth2 eno2: eth3